Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Wall Mount Condensing Gas Boiler<br />
Water (70 - 155 MBH)<br />
Series 1<br />
Part No.<br />
Description - (Input)<br />
Trade<br />
WM97+ Boilers<br />
383-700-000 WM97+70 Blr S1 T-007 (70 MBH) $ 3,920<br />
383-700-001 WM97+110 Blr S1 T-0015 (110 MBH) $ 4,295<br />
383-700-002 WM97+155 Blr S1 T-0015 (155 MBH) $ 5,025<br />
WM97+ Kits<br />
383-500-631 Condensate Neutralizer Kit $ 69<br />
383-700-167 PVC Concentric 2" Vent Kit $ 61<br />
383-500-350 PVC Concentric 3" Vent Kit $ 91<br />
383-700-165 Maintenance Kit $ 60<br />
Ratings<br />
See Water Treatment section for recommended treatment parts<br />
WM97+ 70 WM97+ 110 WM97+ 155<br />
CSA Input 70 MBH 110 MBH 155 MBH<br />
DOE Heating Capacity 65 MBH 101 MBH 143 MBH<br />
Net I=B=R 57 MBH 88 MBH 124 MBH<br />
DOE AFUE 97.3% 97.0% 97.2%<br />
Data Vent Size/Material 2" or 3" PVC/CPVC/PP/SS 3"<br />
Combustion Air Size 2" or 3"<br />
3"<br />
Water Volume 2.8<br />
3.4<br />
Approx. Ship Weight 136<br />
162<br />
Dimensions Supply Tapping 1"<br />
1 1/4"<br />
Return Tapping 1"<br />
1 1/4"<br />
Min. Recommended Pipe Size 1"<br />
1 1/4"<br />
Gas Connection Size 1/2"<br />
1/2"<br />
Carton Dimensions<br />
25" L x 24" W x 46" H<br />
TOP<br />
(70 & 110 Only)<br />
Standard Equipment<br />
Boiler<br />
Stainless Steel Heat Exchanger<br />
30 PSI ASME Relief Valve<br />
Drain Valve<br />
Stainless Steel Burner<br />
with woven steel fiber mesh<br />
Direct Spark Ignition<br />
Variable Speed Blower Assembly<br />
Venturi Mixing System with Air Silencer<br />
Negative Pressure Regulated Gas Valve<br />
50 VA Transformer<br />
Dual Scale Temp. & Pressure Gauge<br />
Outlet Water Temp. Sensor<br />
Inlet Water Temp. Sensor<br />
Flue Gas Temp. Sensor<br />
Outdoor Temp. Sensor<br />
Built-in Primary/Secondary Piping Option<br />
and Built-in Expansion Tank (70 & 110)<br />
Indirect-Fired Water Heater Connections<br />
Water Treatment - Inhibitor & Test Kit<br />
LWCO with Manual Reset & Test Button<br />
Control Module<br />
3.5" LCD Display<br />
Three-zone Circulator Control<br />
with optional domestic hot water priority<br />
Pre-wired Terminal Blocks<br />
Alarm Control Functionality<br />
Ignition Control<br />
High Limit & Modulating Temp. Control<br />
Outdoor Reset<br />
Internal Boiler Circulator*<br />
1" Flanges Taco 007 (70)<br />
1" Flanges Taco 0015 (110 & 155)<br />
FRONT<br />
RIGHT SIDE<br />
Complete Jacket Assembly with<br />
Fully Removable Jacket Front<br />
Mounting Bracket<br />
Sidewall Vent/Air Termination Kit**<br />
On/Off Power Switch<br />
Condensate Trap<br />
Propane Conversion Orifice<br />
BOTTOM<br />
(70 & 110 Only)<br />
Additional Equipment<br />
Concentric Vent Kit<br />
Condensate Neutralizer Kit<br />
* Circulator supplied with boiler cannot be<br />
removed and cannot be used as a zone<br />
circulator in multiple zone systems.<br />
** Includes inside and outside plates,<br />
vent cap and hardware.<br />
TPS #51 (0812) Page 7