94<br />
Boiler<br />
Model<br />
94<br />
Tankless<br />
Heater<br />
No.<br />
Max #<br />
of<br />
Heaters<br />
Intermittent Draw<br />
100°F Ave. Temp Rise<br />
(from 40°F to 140°F<br />
with 200°F Boiler Water)<br />
Tankless Heater Locations<br />
Section Arrangement<br />
(All heaters on right side of boiler.)<br />
894 W&S 3 3,5,7<br />
994 W&S 4 2, 4, 6, 8<br />
1094 W&S 4 2, 4, 7, 9<br />
1194 W&S 4 2, 4, 8, 10<br />
1294 W&S 5 2, 4, 7, 9, 11<br />
1394 W&S 5 3, 5, 8, 10, 12<br />
1494 W&S 6 2, 4, 6, 9, 11,13<br />
1594 W&S 6 2, 4, 6, 10, 12, 14<br />
1694 W&S 7 2, 4, 6, 9, 11, 13, 15<br />
1794 W&S 7 3, 5, 7, 10, 12, 14, 16<br />
1894 W&S 8 2, 4, 6, 8, 11, 13, 15, 17<br />
1994 W&S 8 2, 4, 6, 9, 11, 14, 16, 18<br />
2094 W&S 8 2, 4, 6, 10, 12, 15, 17, 19<br />
2194 W 7 2, 4, 6, 9, 11, 13, 16<br />
2194 S 5 2, 9, 11, 13, 20<br />
2294 W 7 2, 4, 6, 10, 12, 14, 17<br />
2294 S 5 2, 9, 11, 13, 21<br />
2394 W 8 2, 4, 6, 9, 11, 13, 15, 18<br />
2394 S 6 2, 9, 11, 13, 15, 22<br />
2494 W 8 2, 4, 6, 8, 12, 14, 16, 19<br />
2494 S 6 2, 8, 12, 14, 16, 23<br />
2594 W 8 2, 4, 6, 8, 11, 13, 15, 17<br />
2594 S 7 2, 8, 11, 13, 15, 17, 24<br />
Note: Location of TI and SI sections (intermediates with tankless<br />
openings) counting from back to front match jacket knockouts.<br />
Continuous Draw<br />
100°F Ave. Temp Rise<br />
(no recovery period)<br />
Inlet<br />
and<br />
Outlet<br />
Tappings<br />
92-K-34 9 GPM 11 GPM 3/4 in.<br />
Tankless Heater Abbreviations Key<br />
W = Water; S = Steam; F = Front; B = Back<br />
TI = Intermediate Section with Tankless Opening<br />
I = Regular Intermediate Section<br />
SI = Steam Supply Intermediate Section<br />
Note: "I" sections can be substituted for "TI" sections<br />
Part No.<br />
510-512-285<br />
510-512-295<br />
510-512-300<br />
510-512-301<br />
Part No.<br />
Special Order<br />
Special Order<br />
Model 94 Barometric Dampers<br />
Description<br />
Barometric Damper 14"<br />
(for Models 894 thru 994)<br />
Barometric Damper 18"<br />
(for Models 1094 thru 1694)<br />
Barometric Damper 20"<br />
(for Models 1794 thru 2194)<br />
Barometric Damper 24"<br />
(for Models 2294 and 2594)<br />
Model 94 Options<br />
80 PSIG water working<br />
pressure test of sections<br />
Inspection Openings-4 per section<br />
(1-1/2" NPT with brass plug)<br />
94 Supply Tappings<br />
Boiler Type 94 Models Qty-Size<br />
894 - 1294 1 - 6 in.<br />
Water<br />
1394 - 2094 1 - 8 in.<br />
2194 - 2594 1 - 10 in.<br />
894 1 - 8 in.<br />
Steam<br />
994 - 2094 2 - 8 in.<br />
2194 - 2594 2 - 10 in.<br />
94 Return Tappings<br />
Boiler Type 94 Models Qty-Size<br />
894 - 1294 1 - 6 in.<br />
Water<br />
1394 - 2094 1 - 8 in.<br />
2194 - 2594 1 - 10 in.<br />
Steam 894 - 2594 1 - 6 in.<br />
Model 94 Dimensions<br />
Model<br />
A E L<br />
894 --- 76 in. 52-1/2 in.<br />
994 77-5/8 in. 76 in. 58-1/2 in.<br />
1094 83-5/8 in. 76 in. 64-1/2 in.<br />
1194 89-5/8 in. 76 in. 70-1/2 in.<br />
1294 95-5/8 in. 76 in. 76-1/2 in.<br />
1394 101-5/8 in. 76 in. 82-1/2 in.<br />
1494 107-5/8 in. 76 in. 88-1/2 in.<br />
1594 113-5/8 in. 76 in. 94-1/2 in.<br />
1694 119-5/8 in. 76 in. 100-1/2 in.<br />
1794 125-5/8 in. 76 in. 106-1/2 in.<br />
1894 131-5/8 in. 76 in. 112-1/2 in.<br />
1994 137-5/8 in. 76 in. 118-1/2 in.<br />
2094 143-5/8 in. 76 in. 124-1/2 in.<br />
2194 72 in. 82-1/2 in. 130-1/2 in.<br />
2294 78 in. 82-1/2 in. 136-1/2 in.<br />
2394 84 in. 82-1/2 in. 142-1/2 in.<br />
2494 90 in. 82-1/2 in. 148-1/2 in.<br />
2594 96 in. 82-1/2 in. 154-1/2 in.<br />
Notes for Model 94 Boilers<br />
1. Ratings: Net I=B=R water ratings are based on piping and pick-up allowance of 1.15. Net I=B=R steam ratings are based on<br />
the following piping and pickup allowance of 1.288.<br />
2. Gas pressures based on minimum pressure required to inlet of gas train under full-flow conditions.<br />
3. All boiler-burner units to be force draft fired. Vent termination need not exceed the height of the roof by more than 3 feet.<br />
4. Burners for “H” boilers must be capable of firing the boiler at rated input and specified overfire pressure without flame<br />
impingement. Any burner modifications and/or adjustments in the field to obtain proper operation are the responsibility of the<br />
installing contractor and/or start-up engineer.<br />
5. “H” boiler burner mounting plates will have the following permanent tag: “The operation of the burner mounted to this boiler<br />
has not been tested by <strong>Weil</strong>-<strong>McLain</strong>. Contact the burner supplier for all service requirements”.<br />
TPS #51 (0812) Page 61