H-88<br />

Gas-Oil Boilers (less (less Power Burner & & Mounting Plate) Plate)<br />

Water (690-4035 (719-4123 MBH) -– Steam (596-3602 (620-3771 MBH; 2483-15008 2583-15713 Sq.Ft.)<br />

Series 12<br />

Size<br />

Steam<br />

Boiler<br />

Part No.<br />

Water<br />

Boiler<br />

Part No.<br />

Oil<br />

Input<br />

GPH<br />

I=B=R<br />

Gas<br />

Input<br />

MBH<br />

Gross<br />

Output<br />

MBH<br />

I=B=R Net Rating<br />

Steam<br />

MBH<br />

Steam<br />

Sq. Ft.<br />

Water<br />

MBH<br />

Trade Price & Optional Adders<br />

Water<br />

Steam<br />

Optional<br />

Assemble<br />

Sections<br />

Adder<br />

H-488 164-044-214 164-041-214 7.0 1,010 839 629 2,623 730 25.1 10 in. $ 9,106 $ 9,106 $647 $3,530 2,648<br />

H-588 164-054-214 164-051-214 9.4 1,356 1,126 845 3,520 979 33.6 10 in. $ 10,899 $ 10,899 $810 $3,716 3,210<br />

H-688 164-064-214 164-061-214 11.8 1,701 1,413 1,072 4,467 1,229 42.2 10 in. $ 12,918 $ 12,918 $973 $3,940 3,772<br />

H-788 164-074-214 164-071-214 14.2 2,046 1,700 1,311 5,463 1,478 50.8 12 in. $ 14,872 $ 14,872 $1,134 $4,079 4,334<br />

H-888 164-084-214 164-081-214 16.7 2,382 1,987 1,543 6,428 1,728 59.4 12 in. $ 16,665 $ 16,665 $1,295 $4,261 4,896<br />

H-988 164-094-214 164-091-214 18.8 2,737 2,274 1,766 7,356 1,977 67.9 14 in. $ 18,606 $ 18,606 $1,458 $4,444 5,458<br />

H-1088 164-104-214 164-101-214 21.4 3,082 2,561 1,988 8,285 2,227 76.5 14 in. $ 20,440 $ 20,440 $1,620 $4,627 6,020<br />

H-1188 164-114-214 164-111-214 23.8 3,428 2,848 2,211 9,213 2,477 85.1 14 in. $ 22,215 $ 22,215 $1,783 $4,809 6,582<br />

H-1288 164-124-214 164-121-214 26.2 3,773 3,135 2,434 10,142 2,726 93.7 14 in. $ 24,239 $ 24,239 $1,944 $4,991 7,144<br />

H-1388 164-134-214 164-131-214 28.6 4,119 3,422 2,657 11,070 2,976 102.2 14 in. $ 26,099 $ 26,099 $2,107 $5,174 7,706<br />

H-1488 164-144-214 164-141-214 31.0 4,464 3,709 2,880 11,999 3,225 110.8 16 in. $ 27,652 $ 27,652 $2,268 $5,356 8,268<br />

H-1588 164-154-214 164-151-214 33.4 4,809 3,996 3,102 12,927 3,475 119.4 16 in. $ 29,453 $ 29,453 $2,430 $5,539 8,830<br />

H-1688 164-164-214 164-161-214 35.8 5,155 4,283 3,325 13,855 3,724 127.9 16 in. $ 31,273 $ 31,273 $2,591 $5,721 9,392<br />

H-1788 164-174-214 164-171-214 38.2 5,494 4,570 3,548 14,784 3,974 136.5 18 in. $ 32,991 $ 32,991 $2,754 $5,904 9,954<br />

H-1888 164-184-214 164-181-214 40.6 5,845 4,857 3,771 15,712 4,223 145.1 18 in. $ 34,856 $ 34,856 $2,917 $6,086 10,516<br />

Boiler<br />

H.P.<br />

Vent<br />

Connect<br />

Size<br />

Optional<br />

Pkg'd<br />

Boiler<br />

Adder<br />

Approx.<br />

Shipping<br />

&<br />

Lifting<br />

Weight<br />

(Lbs)<br />

Optional Burner Mounting Plates for use with H-88 Boilers<br />

Burner<br />

Model 88<br />

Burner Model<br />

Manufacturer<br />

Boiler<br />

CF1400 (Without UV port) H-488R - H-488<br />

CF1400 (With UV port) H-488R - H-488<br />

Beckett<br />

CF2300A<br />

H-588 - H-788<br />

(Oil Only)<br />

CF2500<br />

H-888 - H-1188<br />

CF3500<br />

H-1288 - H-1388<br />

CG10.6S H-488R - H-488<br />

Beckett<br />

CG25, CG50<br />

H-588 - H-1388<br />

(Gas Only)<br />

CF3500<br />

H-1488<br />

Carlin<br />

Power-Flame<br />

(WJR)<br />

Power-Flame<br />

(WCR)<br />

Webster<br />

Note: Riello burner mounting<br />

plate included with burner<br />

702CRD-W, 801CRD-W<br />

1050FFD<br />

1150FFD<br />

WJ30A-10<br />

WJ50A-15<br />

WCR1-G-12<br />

WCR2-G-15,WCR2-G-20A,WCR2-G-20B<br />

WCR3-G-20,WCR3-G-25,WCR3-G-25B<br />

WCR4-G-25<br />

WJB1G/O/C<br />

WJB1G/O/C<br />

WJB2G/O/C<br />

WJB2O<br />

WJB3G/C<br />

H-488R - H-888<br />

H-988R - H-1088<br />

Burner Mounting<br />

Part Number<br />

386-300-003<br />

386-300-004<br />

386-300-001<br />

386-300-001<br />

386-300-002<br />

386-300-001<br />

386-300-002<br />

386-300-006<br />

386-300-220<br />

Trade<br />

$491<br />

$491<br />

$491<br />

$491<br />

$491<br />

$491<br />

$491<br />

$491<br />

$491<br />

$491<br />

386-300-222<br />

H-1188 - H-1488<br />

H-488R - H-488<br />

H-588 - H-788<br />

H-488R - H-588<br />

386-300-224<br />

386-300-206<br />

386-300-207<br />

386-300-206<br />

$491<br />

$491<br />

$491<br />

$491<br />

H-688 - H-1088R 386-300-207<br />

386-300-208<br />

386-300-230<br />

$491<br />

$491<br />

$491<br />

H-1088 - H-1688<br />

H-1788 - H-1888<br />

H-488R - H-688<br />

H-788 - H-988R<br />

H-988 - H-1688<br />

H-1788 - H-1888<br />

H-1888 Special Order<br />

88 Boiler Model Description<br />

Special Order $883<br />

Special Order $518<br />

Special Order $359<br />

Special Order $431<br />

– 88 – if required<br />

Fuel No. of Blank W=Water F=<br />

L=Oil Sections or or Forced<br />

G=Gas R=Reduced S=Steam Draft<br />

GL=Gas/Oil<br />

Rating<br />

H = Boiler without Burner & Burner Mounting Plate<br />

AH = "H" Unit with Factory Assembled Sections<br />

P = Packaged Boiler/Burner Unit<br />

AB = Factory Assembled Sections - Boiler/Burner Unit<br />

B = Field Assembled Boiler/Burner Unit<br />

Specify:<br />

• Burner Mfr.<br />

• Controls<br />

• Codes<br />

• Voltages<br />

• Other opts.<br />

$431<br />

Standard Equipment<br />

Field Assembled or Packaged<br />

Boilers:<br />

Cast Iron Sections<br />

Insulated Flush Jacket<br />

Flue Collar with Built-in Breeching<br />

Damper<br />

Observation Port on Front and Back<br />

Sections<br />

Cleanout Rates<br />

Flame Retention Burner(except H-88<br />

Boilers)<br />

Burner Mounting Plate with<br />

Refractory<br />

(Except H-88 Boilers)<br />

Flue Brush<br />

Packages Boilers:<br />

Factory Water Tested<br />

Lifting Cables are Attached to Block<br />

Assembly<br />

Steel Skid on Bottom of Boiler<br />

Low Water Cut-Off<br />

Water Boilers #PS-851-120<br />

Steam Boilers #61<br />

Water Boilers:<br />

30 P.S.I ASME Relief Value<br />

(boilers tested for 80 P.S.I working<br />

pressure)<br />

Combination Manual Reset High<br />

Limit and Low Limit Control<br />

Combination Pressure-Temp-Altitude<br />

Gauge<br />

Nipple and 5" x 6" Reducing Coupling<br />

(1288-1888 only)<br />

Built -In Air Eliminator<br />

Steam Boilers:<br />

15 P.S.I. ASME Relief Value - Side<br />

Outlet<br />

Low Limit and High Limit Pressure<br />

Controls<br />

Steam Pressure Gauge<br />

Gauge Glass, Cocks & Guards<br />

Page 42 TPS #51 (0812)