CGt<br />

Induced Draft Gas Boiler with Tankless Heater<br />

Water (95 MBH)<br />

Series 2<br />

Part No. Description - (Input)<br />

Trade Ratings<br />

CGt PIN Boiler - Intermittent (Spark) Pilot - Natural Gas<br />

C.S.A Input<br />

381-357-936 CGt-5 PIN Blr S2 T-007 (133 MBH) $ 3,254<br />

DOE Heating Cap.<br />

CGt Conversion Kit<br />

Net I=B=R<br />

510-811-925 CGt-5 NG to LP Conv Kit $ 173<br />

DOE AFUE<br />

Data<br />

Dimensions<br />

CGT-5<br />

133 MBH<br />

109 MBH<br />

95 MBH<br />

82.1%<br />

CGT-5<br />

Direct Exhaust Venting Use 3-inch AL29-4C vent material<br />

Natural Draft Vent Connector 5 in. I.D. (min size)<br />

Water Volume<br />

3.1 Gal<br />

Approx. Ship Weight<br />

300 lbs.<br />

Supply Tapping<br />

Supply Pipe Size<br />

DHW Inlet/Outlet Tapping<br />

Return Tapping<br />

Return Pipe Size<br />

Gas Connection Size<br />

Carton Dimensions<br />

CGT-5<br />

1-1/4 in.<br />

1 in.<br />

3/4"<br />

1 in.<br />

1 in.<br />

1/2 in. (Natural & Propone Gas)<br />

36" L x 25" W x 35" H<br />

Supply connection, 1 1/4" NPT<br />

Return connection, 1" NPT<br />

Relief valve, 3/4" NPT<br />

1/2" NPT to expansion tank/air vent<br />

3" Diameter vent connection<br />

Gas supply piping<br />

Drain valve<br />

Gas supply entrance (top or side)<br />

Pressure/temperature gauge<br />

3-way valve<br />

Standard Equipment<br />

Factory Tested Thermal Fuse Element Insulated Extended Jacket<br />

Cast Iron Sections<br />

Built-in Air Separator<br />

30 PSI ASME Relief Valve<br />

Drain Valve<br />

Stainless Steel Burners<br />

Non-Linting Pilot Burner<br />

Blower Assembly<br />

High Limit Temp. Control<br />

Comb. Gas Valve & Regulator<br />

Two-Piece Top Jacket Panel<br />

Electrical Junction Box<br />

40 VA Transformer Radiation Plates<br />

Comb. T&P Gauge<br />

Flue Gas Collector Assembly<br />

Wiring Harness<br />

Air Pressure Switch<br />

Integrated Control Module<br />

Circulator (when ordered)<br />

3-way Valve & Piping<br />

Ambient Temp. Switch<br />

Tankless Heater & Controls<br />

Thermostatic Mixing Valve<br />

TPS #51 (0812) Page 13