Safety Compliance Testing for <strong>FMVSS</strong> <strong>201</strong>UI Page 18 of 164<br />

“<strong>Occupant</strong> Protection In Interior Impact”<br />

CC5200 / DTNH22-09-D-00131 / G11I7-001.14<br />

Measurement Description Left Side Right Side<br />

D2 Upper Roof {(Plane C) – (Plane D)} 1714.0 mm<br />

D2/2 D2 ÷ 2 857.0 mm<br />

.35D1 .35 x D1 1360.5 mm<br />

.35D2 .35 x D2 599.9 mm<br />

N B-Pillar {(BPR) – (lowest point on daylight opening forward of B-<br />

Pillar)}<br />

N/2 B-Pillar {(BP3) – (lowest point on daylight opening forward of B-<br />

Pillar)}<br />

N/4 B-Pillar {(BP4) – (lowest point on daylight opening forward of B-<br />

Pillar)}<br />

As determined using the Procedures specified in S10.1-10.13.<br />

649.1 mm 614.2 mm<br />

324.6 mm 307.1 mm<br />

162.3 mm 153.6 mm<br />

SgRP Locations (world coordinates)<br />

Left (mm)<br />

Right (mm)<br />

x y z x y z<br />

Front 1517.0 -455.0 496.0 1517.0 455.0 496.0<br />

SgRP Locations (vehicle coordinates)<br />

Left (mm)<br />

Right (mm)<br />

x y z x y z<br />

Front 1517.0 -455.0 496.0 1517.0 455.0 496.0