25.3 Radar troubleshooting<br />

Problems with the radar and their possible causes and solutions are described here.<br />

Problem Possible causes Possible solutions<br />

No Data or No scanner message<br />

Radar will not initialize (Voltage control<br />

module (VCM) stuck in “sleep mode”<br />

The bearing of a target on the radar<br />

screen is incorrect.<br />

Radar scanner power supply<br />

SeaTalk hs / RayNet network problem<br />

Software mismatch between equipment<br />

may prevent communication.<br />

Switch at scanner pedestal in OFF<br />

position<br />

Intermittent or poor power connection<br />

The radar bearing alignment requires<br />

correcting.<br />

Check that the scanner power supply cable is sound and that all connections<br />

are tight and free from corrosion.<br />

Check relevant fuses and breakers.<br />

Check power source is of the correct voltage and sufficient current (using<br />

voltage booster if appropriate).<br />

Check that the Scanner is correctly connected to a Raymarine network<br />

switch or SeaTalk hs crossover coupler (as applicable).<br />

Check the status of the Raymarine network switch.<br />

Check that SeaTalk hs / RayNet cables are free from damage.<br />

Contact Raymarine technical support.<br />

Ensure scanner pedestal switch is in ON position.<br />

Check power connection at VCM. (Voltage at input = 12 / 24 V, Voltage<br />

at output = 40 V)<br />

Check and adjust radar bearing alignment.<br />