Operators and Installation Manual RA-2500 AIS Receiver.pdf - Jotron
Operators and Installation Manual RA-2500 AIS Receiver.pdf - Jotron
Operators and Installation Manual RA-2500 AIS Receiver.pdf - Jotron
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
This menu gives access to different submenus for readout of parameters.<br />
The only submenu who can give access to changes is the “Service” menu which<br />
is password protected.<br />
Select “BITE” menu by pressing [Enter] key or numeric key [1].<br />
Menu: BIIT 1/3<br />
Temperature:<br />
Rssi <strong>AIS</strong>0….:<br />
Rssi <strong>AIS</strong>1.…:<br />
This menu gives BIIT readout values from the receiver.<br />
Press [Esc] key to go one step back. Select “Alarm Status”<br />
menu by pressing numeric key [2] or [arrow down] key <strong>and</strong> press [Enter ] key.<br />
Menu: Alarm Status 1/1<br />
EPFS<br />
This menu shows the log over momentarily status alarms that have been visualized<br />
in the <strong>AIS</strong> display <strong>and</strong> signed for by pressing [Del] key, but are still valid.<br />
Press [Esc] key to go one step back. Select “System Indicators” menu<br />
by pressing numeric key [3] or [arrow down] key <strong>and</strong> press [Enter] key.<br />
Menu: Indicators 1/2<br />
UTC clock OK<br />
Int. GNSS<br />
This menu shows the momentarily status if sensor is connected.<br />
Press [Esc] key to go one step back. Select “History” menu<br />
by pressing numeric key [4] or [arrow down] key <strong>and</strong> press [Enter ] key.<br />
Menu: History 1/14<br />
Off 19 Feb 2038 03:14<br />
Off 20 Feb 1030 02:07<br />
Off 26 Feb 2029 23:44<br />
This menu shows the log over when the receiver have been<br />
turned off for more than 15 min. Press [Esc] key to go one step back.<br />
82694_Op&Ins MAN_<strong>RA</strong><strong>2500</strong>_D 5-8