Linear fluorescent high bay imx - LSI Industries Inc.

Linear fluorescent high bay imx - LSI Industries Inc. Linear fluorescent high bay imx - LSI Industries Inc.

lsi.industries.com
from lsi.industries.com More from this publisher
17.02.2014 Views

LINEAR FLUORESCENT HIGH BAY PRODUCT HIGHLIGHTS • High efficiency T5 & T8 lamps for significant energy savings over HID high bays. • Unit may be pendant, chain or surface mounted • Hub mounting option allows single-point mount for direct replacement of HID High Bays • Available in 4', and 8' lengths • Shallow fixture depth 3-7/32 • Minimum fixture weight - less load on building structure CONSTRUCTION - Fixture housing, end sections, and lampholders of code gauge die formed steel, standard reflector of code gauge die formed aluminum, MIRO 4 finish. American Innovation American Made ELECTRICAL - All devices UL/CUL listed. Suitable for damp locations. Damp location emergency pack must be specified separately. Ballasts are energysaving, solid-state electronic. Ballasts and lampholders replaceable without removing from ceiling. Discrete voltage must be specified for emergency pack options when wired with flex. Where lamps are included as part of the fixture, lamp CRI and color temperature must be specified. FINISH - All metal parts and housing are finished with high reflectance, lighting fixture white polyester powder after fabrication. PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed photometric data. ARRA Funding Compliant 14-1/4" (362mm) 22 - 1/2” (572 mm) IMX 3-7/32" (82mm) 5” (126 mm) RETAIL/INDUSTRIAL Fluorescent Retail/Industrial Bays IMX-832 XSECTION LUMINAIRE ORDERING INFORMATION TYPICAL ORDER EXAMPLE: IMX 4 54 SS5HO EMDL UE Prefix Lamps Lamp Type Ballasts Options Voltage IMX 2 3 4 6 8 4 6 8 54 - 54W 46” T5 HO 32 - 32W 48" T8 Note: Add -2 for tandem units SS5HO - T5HO Programmed Start SSO - T8 Instant Start SSOD - T8 Dimming (specify type) SSOL - T8 Low Watt SSOHL- T8 High Ballast Factor SSOHLR- T8 Program Start High Ballast Factor SSOR - T8 Programmed Start (For dual ballasts add “2”. Example: SSO2. Specify if special configuration required. Example: 2 lamp/4 ballast) F - Fusing EM - Emergency Pack EMDL - Emergency Pack - Damp Location OCS - Occupancy Sensor (specify type) 1 * WHT - White Reflector HUB - Hub Mounting Hardware 3/4" NPS U - Uplight reflector CHS IMX - V hook chain set (see mounting accessories) LM - Lamps Installed (specify type) CEE - CEE Approved Components installed *(See Fluorescent Highbay Accessories for more options) 120 - 120V 277 - 277V 347 - 347V UE - Universal Electronic (120-277V) ACCESSORY ORDERING INFORMATION Description Wire Guard Prismatic Acrylic Lens Door Assembly Clear Acrylic Lens Door Assembly *SEE FLUORESCENT HIGHBAY ACCESSORIES PAGE (Accessories are field installed) Order Number WG-IMX PAX-A PAX-C FOOTNOTES: 1 - Can only be used with Programmed Start ballast. INDOOR Project Name Catalog # Fixture Type 03/29/12 © 2012 LSI INDUSTRIES INC. 411

LINEAR FLUORESCENT HIGH BAY<br />

PRODUCT HIGHLIGHTS<br />

• High efficiency T5 & T8 lamps for<br />

significant energy savings over HID <strong>high</strong><br />

<strong>bay</strong>s.<br />

• Unit may be pendant, chain or surface<br />

mounted<br />

• Hub mounting option allows single-point<br />

mount for direct replacement of HID<br />

High Bays<br />

• Available in 4', and 8' lengths<br />

• Shallow fixture depth 3-7/32<br />

• Minimum fixture weight - less load on<br />

building structure<br />

CONSTRUCTION - Fixture housing, end<br />

sections, and lampholders of code<br />

gauge die formed steel, standard<br />

reflector of code gauge die formed<br />

aluminum, MIRO 4 finish.<br />

American Innovation<br />

American Made<br />

ELECTRICAL - All devices UL/CUL listed.<br />

Suitable for damp locations. Damp<br />

location emergency pack must be<br />

specified separately. Ballasts are energysaving,<br />

solid-state electronic. Ballasts<br />

and lampholders replaceable without<br />

removing from ceiling. Discrete voltage<br />

must be specified for emergency pack<br />

options when wired with flex. Where<br />

lamps are included as part of the fixture,<br />

lamp CRI and color temperature must be<br />

specified.<br />

FINISH - All metal parts and housing are<br />

finished with <strong>high</strong> reflectance, lighting<br />

fixture white polyester powder after<br />

fabrication.<br />

PHOTOMETRICS - Please visit our web<br />

site at www.lsi-industries.com for<br />

detailed photometric data.<br />

ARRA<br />

Funding Compliant<br />

14-1/4"<br />

(362mm)<br />

22 - 1/2”<br />

(572 mm)<br />

IMX<br />

3-7/32"<br />

(82mm)<br />

5”<br />

(126 mm)<br />

RETAIL/INDUSTRIAL<br />

Fluorescent Retail/Industrial Bays<br />

IMX-832 XSECTION<br />

LUMINAIRE ORDERING INFORMATION<br />

TYPICAL ORDER EXAMPLE:<br />

IMX 4 54 SS5HO EMDL UE<br />

Prefix<br />

Lamps<br />

Lamp Type<br />

Ballasts Options Voltage<br />

IMX 2<br />

3<br />

4<br />

6<br />

8<br />

4<br />

6<br />

8<br />

54 - 54W 46” T5 HO<br />

32 - 32W 48" T8<br />

Note: Add -2 for<br />

tandem units<br />

SS5HO - T5HO Programmed Start<br />

SSO - T8 Instant Start<br />

SSOD - T8 Dimming (specify type)<br />

SSOL - T8 Low Watt<br />

SSOHL- T8 High Ballast Factor<br />

SSOHLR- T8 Program Start High Ballast Factor<br />

SSOR - T8 Programmed Start<br />

(For dual ballasts add “2”. Example: SSO2. Specify if special<br />

configuration required. Example: 2 lamp/4 ballast)<br />

F - Fusing<br />

EM - Emergency Pack<br />

EMDL - Emergency Pack - Damp Location<br />

OCS - Occupancy Sensor (specify type) 1 *<br />

WHT - White Reflector<br />

HUB - Hub Mounting Hardware 3/4" NPS<br />

U - Uplight reflector<br />

CHS IMX - V hook chain set (see mounting accessories)<br />

LM - Lamps Installed (specify type)<br />

CEE - CEE Approved Components installed<br />

*(See Fluorescent High<strong>bay</strong> Accessories for more options)<br />

120 - 120V<br />

277 - 277V<br />

347 - 347V<br />

UE -<br />

Universal<br />

Electronic<br />

(120-277V)<br />

ACCESSORY ORDERING INFORMATION<br />

Description<br />

Wire Guard<br />

Prismatic Acrylic Lens Door Assembly<br />

Clear Acrylic Lens Door Assembly<br />

*SEE FLUORESCENT HIGHBAY ACCESSORIES PAGE<br />

(Accessories are field installed)<br />

Order Number<br />

WG-IMX<br />

PAX-A<br />

PAX-C<br />

FOOTNOTES:<br />

1 - Can only be used with Programmed Start ballast.<br />

INDOOR<br />

Project Name<br />

Catalog #<br />

Fixture Type<br />

03/29/12<br />

© 2012<br />

<strong>LSI</strong> INDUSTRIES INC.<br />

411


IMX (3,4 & 6 LAMP)<br />

DIMENSIONS<br />

3 7/32"<br />

14 1/4"<br />

3 LAMP<br />

3 7/32"<br />

14 1/4"<br />

4 LAMP<br />

14 1/4"<br />

[362.0mm]<br />

6 LAMP<br />

3 1/4"<br />

[81.7mm]<br />

MOUNTING<br />

(8) CHAIN HANGING SLOT SETS<br />

COMBINATION HEAT REMOVAL AND OPTIONAL UP-LIGHT SLOTS<br />

3"<br />

[76.2mm]<br />

1 1/4"<br />

[31.8mm]<br />

2 1/4"<br />

[58.0mm]<br />

ACCESS PLATE W/<br />

(2) 7/8" K.O.'S<br />

1 1/2"<br />

[38.1mm]<br />

1"<br />

[24.6mm]<br />

1 3/8"<br />

[35.4mm]<br />

(3) 7/8"<br />

[ 22.2mm]<br />

4' FIXTURE<br />

2 5/8"<br />

[66.0mm]<br />

10 3/4"<br />

[272.0mm]<br />

24"<br />

[610.5mm]<br />

48 1/8"<br />

[1221.0mm]<br />

(8) CHAIN HANGING SLOT SETS<br />

COMBINATION HEAT REMOVAL AND OPTIONAL UP-LIGHT SLOTS<br />

1 1/4"<br />

[31.8mm]<br />

2 1/4"<br />

[58.0mm]<br />

(2) ACCESS PLATE W/<br />

(2) 7/8" K.O.'S<br />

(4) 7/8"<br />

[ 22.2mm]<br />

3"<br />

[76.2mm]<br />

2 5/8"<br />

[66.0mm]<br />

10 3/4"<br />

[272.0mm] 61 1/4"<br />

[1557.2mm] 96 1/8"<br />

[2440.2mm]<br />

8' FIXTURE<br />

PHOTOMETRICS<br />

2375<br />

4750<br />

Candelas<br />

7125<br />

9500<br />

0<br />

10<br />

20<br />

Catalog# IMX-454-HO-SSO<br />

Report# 11687<br />

Spacing Criterion 1.24 (0-180) x 0.98 (90-270)<br />

Yearly Cost of 1000 Lumens, 3000 Hours of 0.08 KWH = 2.7<br />

30<br />

Plane Displayed<br />

0.0<br />

45.0<br />

90.0<br />

40<br />

50<br />

60<br />

70<br />

Elevation<br />

Angle<br />

90<br />

80<br />

Candle Power Summary<br />

Vertical<br />

Degree<br />

Horizontal Angle<br />

0 45 90<br />

0 9496 9496 9496<br />

5 9411 9407 9393<br />

10 9568 9504 9293<br />

15 9218 8914 8303<br />

20 9257 8360 7599<br />

25 8374 7148 6605<br />

30 7831 6340 6097<br />

35 7173 5676 5375<br />

40 6644 5179 4943<br />

45 6308 4693 4400<br />

50 5297 4006 3452<br />

55 4557 3277 3048<br />

60 3610 2437 2405<br />

65 2884 2033 2216<br />

70 2055 1590 1872<br />

75 1268 1265 1322<br />

80 632 789 711<br />

85 175 257 196<br />

90 0 0 0<br />

Effi ciency 106.10%<br />

LER<br />

FI-89<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixt<br />

0-30 6845.93 34.2 32.3<br />

0-40 10616.88 53.1 50<br />

0-60 17401.24 87 82<br />

0-90 21226.34 106.1 100<br />

90-120 0 0 0<br />

90-130 0 0 0<br />

90-150 0 0 0<br />

90-180 0 0 0<br />

0-180 21226.34 106.1 100<br />

Coeffi cients Of Utilization - Zonal Cavity Method<br />

Effective Floor Cavity Refl ectance 0.20<br />

RC 80 70 50<br />

RW 70 50 30 10 70 50 30 10 50 30 10<br />

0 126 126 126 126 123 123 123 123 118 118 118<br />

1 116 111 107 103 113 109 105 101 104 101 98<br />

2 106 98 91 85 103 96 89 84 92 87 82<br />

3 97 87 78 72 95 85 77 71 82 75 70<br />

4 89 77 68 61 87 76 68 61 73 66 60<br />

5 83 69 60 54 80 68 60 53 66 58 53<br />

6 77 63 54 47 75 62 53 47 60 52 47<br />

7 71 57 48 42 69 56 48 42 55 47 42<br />

8 66 53 44 38 65 52 44 38 50 43 37<br />

9 62 48 40 34 61 48 40 34 47 39 34<br />

10 59 45 37 31 57 44 37 31 43 36 31<br />

04/19/10<br />

© 2010<br />

<strong>LSI</strong> INDUSTRIES INC.<br />

Project Name<br />

Catalog #<br />

Fixture Type

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!