Even when the sun shading is active, the<br />

views of the surroundings are completely<br />

unobstructed, allowing occupants to fully<br />

enjoy the panorama.<br />

The fact that the building is oriented<br />

towards the south optimises passive solar<br />

yields. Add the high-quality glazing and<br />

exterior sun shading slats and you get an<br />

optimum utilisation of natural light.<br />

Structural and energetic conside-<br />

value is equivalent to 1. The value of the<br />

losses and to achieve set targets. With<br />

Intelligent interlinking<br />

“The Berghalde <strong>house</strong> is a harmonious marriage of a purist architectural idiom and<br />

rations<br />

WAREMA products is clear: The sun<br />

comprehensive monitoring, the current<br />

In the net <strong>plus</strong> <strong>energy</strong> <strong>house</strong>, the <strong>energy</strong><br />

innovative <strong>energy</strong> technology. The aim of the planning project was to design and build<br />

The extensive range of information and<br />

shading system in the net <strong>plus</strong> <strong>energy</strong><br />

<strong>energy</strong> consumption is visible at all<br />

system works hand in hand with the<br />

a net <strong>plus</strong> <strong>energy</strong> <strong>house</strong> which, thanks to its photovoltaic installation on the roof, con-<br />

advisory services from WAREMA en-<br />

<strong>house</strong> reduces the <strong>energy</strong> input by the<br />

times, raising awareness about how to<br />

systems for recording, analysing, regula-<br />

verts more solar <strong>energy</strong> into electricity in a year than it consumes. The great thermal<br />

sure that the best sun shading solution<br />

sun considerably and therefore helps to<br />

act more <strong>energy</strong>-efficiently in daily life.<br />

ting and storing power, even the use of<br />

insulation in the building envelope and the excellent sun shading are prerequisites for<br />

can be found for every project – in terms<br />

achieve maximum <strong>energy</strong> efficiency<br />

the electric vehicles is encompassed.<br />

this concept. On the whole, we have created an environmentally friendly building of the<br />

of heat reflection, utilising and directing<br />

while maintaining excellent living comfort<br />

In the Berghalde <strong>house</strong>, the available<br />

future, which makes its occupants feel comfortable – it is a Smart Building for the<br />

natural light, optimum comfort and sus-<br />

in the <strong>house</strong>.<br />

<strong>energy</strong> is used and consumed optimally.<br />

What is more, in <strong>Leonberg</strong>, particular<br />

planned Smart Grids.”<br />

tainability.<br />

The annual renewable output is enough<br />

attention is given to the interface with<br />

Univ. Prof. Dr.-Ing. M. N. Fisch,<br />

In the case of the Berghalde <strong>house</strong>,<br />

An optimised integral system<br />

to charge and drive a small electric car<br />

the public distribution grid. It has not<br />

Director of EGS-Plan GmbH, Stuttgart, and Head of the Institute of Building Services<br />

WAREMA helped making sure that the<br />

All other system components have also<br />

approx. 15,000 kilometres per year.<br />

yet been adapted for the temporal<br />

and Energy Design at the Technical University of Brunswick<br />

strict requirements on <strong>energy</strong> use were<br />

been selected with a view to optimising<br />

fluctuations in load that occur when<br />

satisfied already in the planning stage.<br />

the use of <strong>energy</strong>. The system consists<br />

renewable <strong>energy</strong> is input. The intelligent<br />

The efficiency of the mounted sun<br />

of an electric heat pump with an accu-<br />

power load management ensures that<br />

shading could therefore be determined<br />

mulator tank in combination with three<br />

as little as possible of the <strong>energy</strong> produ-<br />

exactly through structural calculations<br />

geothermal probes. A floor heating<br />

ced in the <strong>house</strong> is fed to the public dis-<br />

(as per DIN EN 13363). The WAREMA<br />

system distributes the heat throughout<br />

tribution grid.<br />

external venetian blinds achieve an Fc<br />

the <strong>house</strong>. The heat recovery ventilation<br />

value of 0.09 to 0.15. The shading factor<br />

system, just like all the other relevant<br />

The Berghalde <strong>house</strong> is therefore an<br />

FC indicates the relationship between<br />

system functions, can be regulated as<br />

energetic trailblazer, while providing a<br />

the total solar <strong>energy</strong> transmittance<br />

required by the occupants of the <strong>house</strong><br />

superb feel-good factor for its users.<br />

through a window with and without sun<br />

thanks to the building control system<br />

shading. In other words, the smaller the<br />

(BCS). Moreover, the innovative BCS<br />

value, the more efficient is the sun<br />

supports and monitors all indoor para-<br />

shading, since less heat <strong>energy</strong> gets into<br />

meters such as temperature, light and<br />

the room; without sun shading, the FC<br />

sun shading, in order to avoid <strong>energy</strong><br />

6<br />

7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!