SOLAR HEATING

SOLAR HEATING SOLAR HEATING

<strong>SOLAR</strong> <strong>HEATING</strong>


COMPLETELY Y READY FOR COMBINATION<br />

WITH <strong>SOLAR</strong> <strong>HEATING</strong> SYSTEMS<br />

Atmospheric<br />

istantaneous<br />

Condensing<br />

istantaneous<br />

Atmospheric<br />

istantaneous<br />

Condensing<br />

istantaneous<br />

Condensing<br />

istantaneous<br />

Atmospheric<br />

istantaneous<br />

Atmospheric<br />

istantaneous


NATURAL CIRCULATION SYSTEMS<br />

ECOLUX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4<br />

ECOPACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5<br />

FORCED CIRCULATION SYSTEMS<br />

ECOTOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6<br />

ECOTUBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7<br />

ECOUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8<br />

IDRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9<br />

ECOTRONIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9<br />

COMBINATIONS AND APPLICATION DIAGRAMS<br />

READY FOR COMBINATION WITH BOILERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10<br />

NATURAL CIRCULATION SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10<br />

FORCED CIRCULATION SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11<br />

3


ECOLUX NATURAL CIRCULATION SYSTEM<br />

- Complete system with flat collector, assembly frame, storage cylinder and<br />

water circuit connection fittings.<br />

- Single aluminium frame that can be used for both flat roofs and sloping roofs.<br />

- Side cover strips as standard.<br />

- 160, 200 and 300 litre storage cylinders with backup electric heater as<br />

standard (1500 W), complete with thermostat.<br />

- No electrical components required, such as temperature controllers or pumps.<br />

- Double insulation, polyurethane + glass wool.<br />

- Antifreeze liquid supplied as standard.<br />

- Absorber with selective titanium oxide coating.<br />

- Conforms to EN 12975.<br />

Model ECOLUX 160 ECOLUX 200 ECOLUX 300<br />

Dimensions (WxDxH) mm 1390 x 2130 x 1910 1390 x 2130 x 1960 2150 x 2130 x 1960<br />

Useful surface area m 2 2,32 2,32 3,56<br />

Operating weight kg 289 344 479<br />

Empty weight kg 135 148 187<br />

Closed circuit volume l 8 8,3 11<br />

Number of collectors no. 1 1 2<br />

Storage cylinder volume l 160 200 300<br />

Storage cylinder treatment<br />

Ceramic glass<br />

Operating temperature range °C - 15 a + 95<br />

Selective coating<br />

Titanium oxide<br />

Absorption factor % 95<br />

Emission factor % 5<br />

Collector heat insulation<br />

30 mm glass wool + 20 mm polyurethane<br />

Heat carrier circuit fittings ø 3/4”<br />

Domestic hot water circuit fittings ø 1/2”<br />

Maximum primary circuit operating pressure bar 1,5<br />

Maximum secondary circuit operating pressure bar 13<br />

Maximum primary circuit operating temperature °C 175<br />

Maximum secondary circuit operating temperature °C 95<br />

Storage cylinder cathodic protection<br />

magnesium anode<br />

Antifreeze liquid supplied as standard l 2 2 3<br />

Minimum operating temperature* °C -10 -10 -12<br />

* The protection temperature indicated refers to the primary circuit only (water-glycol mix) with empty domestic hot water storage cylinder. If the domestic hot water circuit is not emptied, the electric heater,<br />

supplied as standard, should be used in this circuit as protection against frost. For correct installation, always refer to the manual supplied with the product.<br />

** For combinations with boilers for the production of domestic hot water.<br />

ACCESSORIES<br />

DESCRIPTION<br />

Pack of glycol (1 kg)<br />

Thermostatic mixer kit**<br />

Typical examples<br />

ECOLUX Max no. of people*<br />

160 2 - 3<br />

200 3 - 4<br />

300 5 - 6<br />

*NB - The data shown are purely indicative<br />

and refer to collectors that are correctly positioned.<br />

The ideal system is chosen considering<br />

the actual consumption of domestic hot<br />

water in the home in question.<br />

4


ECOPACK<br />

NATURAL CIRCULATION SYSTEM<br />

- Complete system with flat collector, assembly frame, storage cylinder and<br />

water circuit connection fittings.<br />

- Frames available for flat roofs or for sloping roofs (optional).<br />

- 160 and 300 litre storage cylinders with backup electric heater as standard<br />

(1500 W), complete with thermostat.<br />

- No electrical components required, such as temperature controllers or pumps.<br />

- Antifreeze liquid supplied as standard.<br />

- Absorber with selective titanium oxide coating.<br />

- Conforms to EN 12975.<br />

Model ECOPACK 160 ECOPACK 300<br />

Dimensions (WxDxH) mm 1390 x 2080 x 2010 2150 x 2080 x 2010<br />

Useful surface area m 2 1,78 3,56<br />

Operating weight kg 272 478<br />

Empty weight kg 114 181<br />

Primary circuit volume l 8 11<br />

Number of collectors no. 1 2<br />

Storage cylinder volume l 160 300<br />

Storage cylinder treatment Ceramic glass Ceramic glass<br />

Operating temperature range °C - 15 a + 95 - 15 a + 95<br />

Selective coating Titanium oxide Titanium oxide<br />

Absorption factor % 95 95<br />

Emission factor % 5 5<br />

Collector heat insulation 20 mm glass wool 20 mm glass wool<br />

Heat carrier circuit fittings ø 3/4” 3/4”<br />

Domestic hot water circuit fittings ø 1/2” 1/2”<br />

Maximum primary circuit operating pressure bar 1,5 1,5<br />

Maximum secondary circuit operating pressure bar 13 13<br />

Maximum operating temperature closed circuit °C 160 160<br />

Maximum secondary circuit operating temperature °C 95 95<br />

Storage cylinder cathodic protection magnesium anode magnesium anode magnesium anode<br />

Antifreeze liquid supplied as standard l 2 3<br />

Minimum operating temperature* °C -10 -12<br />

ACCESSORIES<br />

Complete assembly frames FLAT ROOF SLOPING ROOF FLAT ROOF SLOPING ROOF<br />

* The protection temperature indicated refers to the primary circuit only (water-glycol mix) with empty domestic hot water storage cylinder. If the domestic hot water circuit is not emptied, the electric heater,<br />

supplied as standard, should be used in this circuit as protection against frost. For correct installation, always refer to the manual supplied with the product.<br />

** For combinations with boilers for the production of domestic hot water.<br />

ACCESSORIES<br />

DESCRIPTION<br />

Pack of glycol (1 kg)<br />

Thermostatic mixer kit**<br />

Typical examples<br />

ECOPACK Max no. of people*<br />

160 2<br />

300 5 - 6<br />

*NB - The data shown are purely indicative<br />

and refer to collectors that are correctly positioned.<br />

The ideal system is chosen considering<br />

the actual consumption of domestic hot<br />

water in the home in question.<br />

5


ECOTOP FLAT <strong>SOLAR</strong> COLLECTOR WITH FORCED CIRCULATION<br />

- High efficiency flat collector with forced circulation.<br />

- Frames available for both flat roofs and sloping roofs (optional).<br />

- Fittings for interconnection between collectors supplied as standard.<br />

- Absorber with selective titanium oxide coating.<br />

- Conforms to EN 12975.<br />

- Available both in the horizontal (H) and vertical (V) versions.<br />

ECOTOP V<br />

ECOTOP H<br />

Model ECOTOP H ECOTOP V<br />

Dimensions mm 2000 x 1170 x 83 1170 x 2000 x 83<br />

Useful surface area m 2 2,14 2,14<br />

Empty weight kg 44 44<br />

Closed circuit volume l 1,60 1,60<br />

Stagnation temperature °C 210 210<br />

Selective coating Titanium oxide Titanium oxide<br />

Absorption factor % 95 ± 2 95 ± 2<br />

Emission factor % 5 ± 2 5 ± 2<br />

Collector heat insulation 40 mm rock wool, black supp. 40 mm rock wool, black supp.<br />

Heat carrier circuit fittings ø 3/4” 3/4”<br />

Maximum primary circuit operating pressure bar 10 10<br />

Number of fittings on each collector no. 2 4<br />

Maximum number of collectors directly connectable no. 4 (series) 6 (parallel)<br />

ACCESSORIES: COMPLETE ASSEMBLY FRAMES, FOR SYSTEMS ON FLAT ROOFS OR SLOPING ROOFS<br />

ECOTOP H SLOPING ROOF FLAT ROOF<br />

NO. OF COLLECTORS CODE CODE<br />

1 076100X0 076104X0<br />

2 076101X0 076105X0<br />

3 076102X0 076106X0<br />

4 076103X0 076107X0<br />

ECOTOP SLOPING ROOF FLAT ROOF<br />

NO. OF COLLECTORS CODE CODE<br />

2 076110X0 076115X0<br />

3 076111X0 076116X0<br />

4 076112X0 076117X0<br />

5 076113X0 076118X0<br />

6 076114X0 076119X0<br />

ACCESSORIES<br />

DESCRIPTION<br />

Plug kit (1 male plug + 1 female plug ) for ECOTOP V<br />

Pack of glycol (5 kg)<br />

Thermostatic mixer kit*<br />

* For combinations with boilers for the production of domestic<br />

hot water.<br />

6


ECOTUBE VACUUM <strong>SOLAR</strong> COLLECTOR WITH FORCED CIRCULATION<br />

- High-efficiency vacuum solar collector with forced circulation.<br />

- Frames available for both flat roofs and sloping roofs (optional).<br />

- Fittings for interconnection between collectors supplied as standard.<br />

- Absorber with selective titanium oxide coating.<br />

- Conforms to EN 12975.<br />

Model ECOTUBE 14<br />

Dimensions mm 1560 x 1647 x 107<br />

Useful absorbent surface area m 2 2,36<br />

Surface on horizontal plane m 2 0,746<br />

Empty weight kg 42<br />

Closed circuit volume l 2,27<br />

Stagnation temperature °C 270<br />

Selective coating<br />

Titanium oxide<br />

Absorption factor % 96 ± 1<br />

Emission factor % 6 ± 1<br />

Heat carrier circuit fittings ø 3/4”<br />

Maximum primary circuit operating pressure bar 10<br />

Number of fittings on each collector no. 2<br />

Maximum number of collectors directly connectable no. 6<br />

ACCESSORIES: COMPLETE ASSEMBLY FRAMES, FOR SYSTEMS ON FLAT ROOFS OR SLOPING ROOFS<br />

ECOTUBE 14 SLOPING ROOF FLAT ROOF<br />

NO. OF COLLECTORS CODE CODE<br />

2 076130X0 076135X0<br />

3 076131X0 076136X0<br />

4 076132X0 076137X0<br />

5 076133X0 076138X0<br />

6 076134X0 076139X0<br />

ACCESSORIES<br />

DESCRIPTION<br />

Pack of glycol (1 kg)<br />

Thermostatic mixer kit*<br />

* For combinations with boilers for the production of domestic hot water.<br />

7


ECOUNIT STORAGE CYLINDER WITH COIL<br />

- Vertical storage cylinders with one (vers. 1C) or two (vers. 2C) coils.<br />

- Vitrified steel storage cylinder.<br />

- Magnesium anodes as standard.<br />

- Backup electric heaters (optional).<br />

<br />

Version 1C<br />

<br />

<br />

Version 2C<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KW-WW Domestic hot water fittings Tr Probe sheath PV-PR Coil fittings Z Recirculation fittings<br />

ECOUNIT 200-1C 300-1C 400-1C 500-1C 200-2C 300-2C 400-2C 500-2C<br />

Capacity l 200 300 400 500 200 300 400 500<br />

Heat exchange surface, top/bottom m 2 — / 1,00 — / 1,40 — / 1,70 — / 2,10 0,50 / 0,85 0,90 / 1,40 0,90 / 1,70 0,90 / 2,10<br />

Heat output (∆t 35°C) kW 30 44 55 63 22/27 31,5/44 31,5/55 31,5/63<br />

DHW production (∆t 35°C) l/h 737 1081 1351 1543 541/663 774/1081 774/1351 774/1543<br />

Max operating temperature °C 95 95 95 95 95 95 95 95<br />

Primary flow-rate mc/h 2,0 3,0 3,0 3,0 2,0 3,0 3,0 3,0<br />

Max operating pressure bar 10 10 10 10 10 10 10 10<br />

Net weight kg 66 97 123 144 61 105 133 154<br />

Domestic hot water fittings ø 3/4” 1” 1” 1” 3/4” 1” 1” 1”<br />

Exchanger fittings ø 3/4” 1” 1” 1” 3/4” 1” 1” 1”<br />

Recirculation fittings ø 3/4” 1” 1” 1” 3/4” 1” 1” 1”<br />

Probes no. 2 2 2 2 3 3 3 3<br />

Recommended vessel (not supplied - see table on the side) l 8 12 18 24 8 12 18 24<br />

Dimensions A mm 610 650 750 750 610 650 750 750<br />

B mm 620 675 775 775 620 675 775 775<br />

C mm 1329 1560 1553 1818 1329 1560 1553 1818<br />

D mm 150 148 162 162 150 148 162 162<br />

E mm 311 338 392 392 261 288 322 322<br />

F mm 486 538 560 554 336 378 402 437<br />

G mm 651 828 782 932 581 693 722 872<br />

H mm 801 978 932 1082 661 773 800 972<br />

L mm 881 1058 1012 1162 747 859 879 1072<br />

M mm 1195 1408 1387 1652 841 956 977 1172<br />

N mm — — — — 1041 1225 1177 1372<br />

O mm — — — — 1108 1292 1259 1457<br />

P mm — — — — 1195 1408 1387 1652<br />

ACCESSORIES<br />

DESCRIPTION<br />

Backup electric heater kit complete with flange and control thermostat<br />

1500 W<br />

2000 W<br />

8


IDRO CIRCULATOR ASSEMBLY<br />

- 3-speed pump.<br />

- Ready to house control unit (optional).<br />

- System fill and drain valve.<br />

- Needle thermometers for central heating outlet and inlet supplied as standard.<br />

- Bracket kit for wall mounting.<br />

- Polypropylene foam insulation.<br />

- Expansion vessel mounting brackets.<br />

- Safety system with safety valve and pressure gauge.<br />

- Flow regulating valve with gauge.<br />

Model IDRO 6 IDRO 12<br />

Dimensions (vessel not included) mm 260 x 500<br />

Rated diameter<br />

DN20<br />

Fittings ø 3/4”<br />

Maximum pressure bar 8<br />

Maximum temperature °C 120<br />

Maximum number of collectors 6 12<br />

ACCESSORIES: VESSEL FOR “ECOUNIT” STORAGE CYLINDER AND “IDRO” ASSEMBLY<br />

DESCRIPTION ECOUNIT IDRO Assembly<br />

8 litres 200 up to 3<br />

12 litres 300 up to 6<br />

Expansion vessel kit *<br />

Collectors**<br />

18 litres 400<br />

up to 12<br />

24 litres 500 —<br />

* Maximum pressure: 10 bars.<br />

** Estimating a distance between the solar collectors and the Idro assembly of 30+30 m: 18 mm dia. pipes for 3 collectors and 22 mm dia. pipes for up to 12 collectors.<br />

ECOTRONIC CONTROL UNIT *NB - The data shown are purely indicative<br />

ECOTRONIC<br />

- Control unit for standard solar heating systems.<br />

- Multifunction display with graphic symbols for the installation.<br />

- Supplied complete as standard with 3 temperature probes.<br />

- Can be housed inside the circulator assembly.<br />

- Power supply: 210-250 Volt.<br />

Typical examples<br />

Collectors ECOTOP ECOTUBE ECOUNIT Max no.*<br />

n° m 2 m 2 l of people<br />

1 2,14 2,36 200 1 - 2<br />

2 4,28 4,72 200 2 - 4<br />

3 6,42 7,08 300 4 - 6<br />

4 8,56 9,44 400 6 - 8<br />

5 10,7 11,8 500 8 - 10<br />

and refer to collectors that are correctly positioned.<br />

The ideal system is chosen considering<br />

the actual consumption of domestic hot<br />

water in the home in question.<br />

9


COMPLETELY Y READY FOR COMBINATION<br />

WITH FERROLI BOILERS<br />

DIAGRAM 1 - 3 (instant) DIAGRAM 2 - 4 (instant) DIAGRAM 5 (central heating only)<br />

■ DIVATOP ■ ECONCEPT 25 C ■ ECONCEPT 15 A<br />

■ DOMIPROJECT ■ ECONCEPT 35 C ■ ECONCEPT 25 A<br />

■ ECONCEPT TECH<br />

■ ECONCEPT 35 A<br />

■ ECONCEPT 50 A<br />

■ DIVATOP H<br />

NATURAL CIRCULATION SYSTEMS<br />

1<br />

domestic<br />

utilities<br />

outside<br />

probe<br />

radiant<br />

panel<br />

radiators<br />

thermostatic<br />

mixer<br />

water mains<br />

2<br />

domestic<br />

utilities<br />

outside<br />

probe<br />

radiant<br />

panel<br />

radiators<br />

thermostatic<br />

mixer<br />

thermostat<br />

water mains<br />

10<br />

TYPICAL DIAGRAMS


FORCED CIRCULATION SYSTEMS<br />

3<br />

outside probe<br />

flat and vacuum solar panels<br />

domestic<br />

utilities<br />

radiant<br />

panel<br />

radiators<br />

thermostatic<br />

mixer<br />

water mains<br />

single coil storage cylinder<br />

4<br />

domestic<br />

utilities<br />

outside<br />

probe<br />

flat and vacuum solar panels<br />

radiant<br />

panel<br />

radiators<br />

thermostatic<br />

mixer<br />

thermostat<br />

water mains<br />

single coil storage cylinder<br />

5<br />

outside<br />

probe<br />

domestic<br />

utilities<br />

flat and vacuum solar panels<br />

radiant<br />

panel<br />

radiators<br />

thermostatic<br />

mixer<br />

water mains<br />

double coil storage cylinder<br />

TYPICAL DIAGRAMS<br />

11


11.07<br />

FERROLI around the World<br />

ITALY www.ferroli.it<br />

SPAIN www.ferroli.es<br />

FRANCE www.ferroli.fr<br />

UNITED KINGDOM www.ferroli.co.uk<br />

NETHERLANDS www.agpoferroli.nl<br />

GERMANY www.ferroli.de<br />

TURKEY www.ferroli.com.tr<br />

ROMANIA www.ferroli.ro<br />

POLAND www.ferroli.com.pl<br />

RUSSIA www.ferroli.msk.ru<br />

UKRAINE www.ferroli.ua<br />

BELARUS www.ferroli.by<br />

CHINA www.ferroli.com.cn<br />

BALKANS www.ferroli.hr<br />

IRAN www.ferroli.ir<br />

Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A<br />

tel. +39.045.6139411 ¬ fax +39.045.6100233<br />

www.gruppoferroli.com ¬ e-mail: export@ferroli.it<br />

WARNING FOR TRADERS: As part of its efforts to constantly improve<br />

its range of products, with the aim of increasing the level of Customer<br />

satisfaction, the Company stresses that the appearance, dimensions,<br />

technical data and accessories may be subject to variation.<br />

Consequently, ensure that the Customer is provided with updated<br />

documents. The products described in this document are covered by<br />

warranty if purchased and installed in Italy.