Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
2.1.24.2.2 2-wire Universal Digital Channel (IDSL Compatible)<br />
.<br />
2.1.24.2.3<br />
2.1.24.2.4<br />
2.1 24.2.5<br />
2.1.24.2.6<br />
2.1.24.2.7<br />
2.1.24.2.8<br />
2.1.24.2.9<br />
2.1 24.2.1 0<br />
2.1.24.2.1 1<br />
2.1.24.2.1 2<br />
2.1.24.3<br />
2.1.24.4<br />
2.1.24.5<br />
2. I .24.6<br />
2.1.24.7<br />
2-wire Unbundled ADSL Compatible Loop<br />
2-wire Unbundled HDSL Compatible Loop<br />
4-wire Unbundled HDSL Compatible Loop<br />
4-wire Unbundled DS1 Digital Loop<br />
4-wire Unbundled Digital Loop/DSO - 64 kbps, 56 kbps and below<br />
DS3 loop<br />
STS-1 LOOP<br />
OC3 Loop<br />
oc12 Loop<br />
OC48 Loop -+-<br />
2-Wire Unbundled ISDN Digital Loops will be provisioned<br />
according to industry standards for 2-Wire Basic Rate ISDN<br />
services and will come standard with a test point, Order.<br />
Coordination, and a DLR. Network Telephone Corporation will be<br />
responsible for providing BellSouth with a <strong>Service</strong> Profile Identifier<br />
(SPID) associated with a particular ISDN-capable loop and end<br />
user. With the SPID, BellSouth will be able to adequately test the<br />
circuit and ensure that it properly supports ISDN service.<br />
BellSouth will not reconfigure its ISDN-capable loop to support<br />
IDSL service.<br />
The Universal Digital Channel (UDC) (also known as IDSLcompatible<br />
Loop) is intended to be compatible with IDSL service<br />
and has the same physical characteristics and transmission<br />
specifications as BellSouth’s ISDN-capable loop. These<br />
specifications are listed in BellSouth’s TR73600.<br />
The UDC may be provisioned on copper or through a Digital Loop<br />
Carrier (DLC) system. When UDC Loops are provisioned using a<br />
DLC system, the Loops will be provisioned on time slots that are<br />
compatible with data-only services such as IDSL.<br />
2-Wire ADSL-Compatible Loop. This is a designed loop that is<br />
provisioned according to Revised Resistance Design (RRD)<br />
criteria and may be up to 18kft long and may have up to 6kft of<br />
bridged tap (inclusive of loop length). The loop is a 2-wire circuit<br />
and will come standard with a test point, Order Coordination, and<br />
a DLR.<br />
2-Wire or 4-Wire HDSL-Compatible Loop. This is a designed loop<br />
that is provisioned according to Carrier Serving Area (CSA)<br />
criteria and may be up to 12,000 feet long and may have up to