10.2.1 TOOLBAR BUTTONS<br />
Starts an MLS measurement.<br />
If pressed the measurements will be autosaved. The current autosave definitions<br />
apply; see 6.3.1 for details.<br />
Selects the Loop mode. When in Loop mode the MLS measurement is automatically<br />
repeated until the users presses a keystroke or releases the button. If Autosave is<br />
active the loop mode ends after the total files to be autosaved are done.<br />
When an MLS measurement is taken, automatically applies the selected postprocess.<br />
Enters the MLS Process dialog box.<br />
Enters the MLS settings dialog box.<br />
Enters Time domain.<br />
Enters Frequency domain.<br />
Displays phase.<br />
Displays group delay.<br />
10.2.2 TOOLBAR DROP DOWN LISTS<br />
input channel<br />
Selects the input channel configuration.<br />
Y scale unit<br />
Selects the measurement units. It is possible to select Voltage (dBV, dBu, dBRel) or<br />
Pressure (dBSPL) or Impedance (Ohm).<br />
smoothing<br />
Activates a frequency smoothing of the active curve. This smoothing effect will allow<br />
for a better appreciation of the general features of the response curve. The<br />
smoothing algorithm that is employed averages all values within a fraction-of-octave<br />
band surrounding each analysis frequency.<br />
86 Chapter 10 - MLS