find several audio generators that do the job, but they are usually expensive; a good<br />

choice is to use a recorded tracks of one fo the various test CDs available; in this case<br />

not all the CD-ROM readers may furnish adequate results as appears from the graph<br />

in Fig.9.3<br />

0.0<br />

CLIO<br />

dBV<br />

-20.0<br />

-40.0<br />

-60.0<br />

-80.0<br />

-100.0<br />

20 100 1k Hz<br />

10k 20k<br />

Figure 9.3<br />

All three graphs represent true analog pink noises, they are played at 5dB different level<br />

for clarity. The upper (red) is the output of an Audio Precision System One generator;<br />

the second (blue) is the pink noise of track 4 of the Stereophile Test CD played by a<br />

Philips CD692 CD player, the third is the same track of the same test CD output by the<br />

computer where I'm writing right now (Pioneer DVD Player plus Crystal Sound Fusion<br />

<strong>PCI</strong> Audio).<br />

When taking RTA measurements use, at least, 16K FFT size if you want to<br />

cover the entire 20-20kHz audio band; using lower sizes results in octave<br />

bands not present as no FFT bins fall inside them.<br />

Chapter 9 - FFT 81