13.7 THIELE & SMALL PARAMETERS<br />

13.7.1 INTRODUCTION<br />

CLIO handles Thiele and Small Parameters, hereafter TS, as a post process of impedance<br />

measurements. Three options are available for data source, selected by the Data Origin<br />

Drop Down Control: Sinusoidal Impedance Data, Mls Impedance Data, File Data, the<br />

last created with either of the previous. There are no conceptual differences between<br />

File and the first two options, aside where the data resides. Choosing Sinusoidal or Mls,<br />

user should have one of these measurements in memory while the File Data option will<br />

prompt for file selection. Impedance measurements are therefore central topic and the<br />

previous paragraphs are an essential background. To get the full set of TS, two<br />

impedance curves are needed. The first is the loudspeaker free air impedance, the<br />

second, the impedance obtained either with Delta Mass or Delta Compliance method.<br />

The first consists in adding a suitable Known Mass to the Loudspeaker cone, the latter<br />

in loading the cone with a Known Volume.<br />

13.7.2 T&S PARAMETERS CONTROL PANEL<br />

The User Interface is quite simple with three Buttons, one Drop Down and one Check<br />

Box.<br />

Starts a T&S Parameters procedure. See 13.7.3 for details.<br />

Delta mass T&S Parameters calculation. See 13.7.3 for details.<br />

Delta compliance T&S Parameters calculation. See 13.7.3 for details.<br />

The Drop Down allows selecting the data origin as described in the introduction. The MSE<br />

Check Box, when checked, enables a Minimum Square Error routine while calculating<br />

TS Parameters; more on this later. Aside information regarding the device tested the<br />

Control Panel displays 27 parameters. Here is what they are.<br />