kind. Users, however, should always take the maximum effort to avoid these situations<br />

anyway. Furthermore MLS has several advantage over Sinusoidal. The most evident is<br />

execution time which is one order of magnitude better, even using big sizes, which, by<br />

the way, is always advisable. It can measure down to 1Hz while Sinusoidal stops at<br />

10Hz. Its high sensitivity to even week non-linearity can be used to reveal even small<br />

rub&buzz problems, directly from the impedance measure. We advise to use Sinusoidal<br />

for the first experiences. After everybody will be able to get an opinion on personal basis.<br />

Chapter 13 - Measuring impedance and T&S parameters 137