12 WATERFALL<br />
12.1 INTRODUCTION<br />
The Waterfall post processing routines give <strong>CLIOwin</strong> the possibility of making 3-D plots<br />
adding a third dimension (usually time) to classical amplitude-frequency graphs.<br />
<strong>CLIOwin</strong> permits the following 3-D types of waterfall:<br />
- Cumulative spectral decay (CSD)<br />
- Energy Time Frequency (ETF)<br />
- File display (used for polar representation)<br />
12.2 WATERFALL CONTROL PANEL<br />
12.2.1 TOOLBAR BUTTONS<br />
Starts a waterfall calculation.<br />
Figure 12.1<br />
Enters the Waterfall settings dialog. See 12.2.1.<br />
Expands the waterfall display changing its Y scale. Three ranges are available 20,<br />
40 and 80dB.<br />
Compresses the waterfall display changing its Y scale. Three ranges are available<br />
20, 40 and 80dB.<br />
Enters the Marker mode (see Fig. 12.5). In this operating mode it is possible to<br />
inspect the single data points of each waterfall slice clicking and dragging the mouse.<br />
When in marker mode, moves the selected waterfall slice backwards. The same<br />
action is obtained with the Up-Arrow keyboard shortcut.<br />
When in marker mode, moves the selected waterfall slice frontwards. The same<br />
action is obtained with the Down-Arrow keyboard shortcut.<br />