11.3.2 FREQUENCY RESOLUTION<br />
Here the lowest resolution the fastest is the measuring time. Impedance measurements<br />
are again a powerful setup to exploit problems. Fig.11.3 shows two impedance<br />
taken from the same 16" woofer with 1/24 octave resolution (red) and 1/6 octave<br />
resolution (black). Deriving T/S Parameters from the black curve would lead to serious<br />
errors. This is an extreme case, a huge woofer with high Qms. Different curve shapes<br />
can be accurately quantified even with 1/3 octave resolution.<br />
150.0<br />
CLIO<br />
180.0<br />
Ohm<br />
Deg<br />
120.0 108.0<br />
90.0 36.0<br />
60.0 -36.0<br />
30.0 -108.0<br />
0.0 -180.0<br />
10 100<br />
Hz<br />
Figure 11.3<br />
Chapter 11 - Sinusoidal 111