11.3.2 FREQUENCY RESOLUTION<br />

Here the lowest resolution the fastest is the measuring time. Impedance measurements<br />

are again a powerful setup to exploit problems. Fig.11.3 shows two impedance<br />

taken from the same 16" woofer with 1/24 octave resolution (red) and 1/6 octave<br />

resolution (black). Deriving T/S Parameters from the black curve would lead to serious<br />

errors. This is an extreme case, a huge woofer with high Qms. Different curve shapes<br />

can be accurately quantified even with 1/3 octave resolution.<br />

150.0<br />

CLIO<br />

180.0<br />

Ohm<br />

Deg<br />

120.0 108.0<br />

90.0 36.0<br />

60.0 -36.0<br />

30.0 -108.0<br />

0.0 -180.0<br />

10 100<br />

Hz<br />

Figure 11.3<br />

Chapter 11 - Sinusoidal 111