emoved at any moment after the measurement has been taken.<br />

11.2.3 SINUSOIDAL SETTINGS DIALOG<br />

It is undoubtedly the most important User Interface of the entire Menu. Here the single<br />

action of every control is considered. Theoretical and practical effects on the subsequent<br />

measurement are considered later.<br />

Sweep Settings<br />

Stepped Check Box<br />

Lets the user choose between continuous or stepped Logarithmic Sweep. Continuous<br />

sweep is faster but, therefore, should be used only if its clear to the user how<br />

this affects the measure.<br />

Resolution Drop Down<br />

Lets the user choose between five different Frequency resolutions. It affects the<br />

measurement execution time, whatever are the other settings.<br />

Freq Max Edit Box<br />

Lets the user define the highest Frequency of the Sweep. This is also the starting<br />

measurement Frequency. The highest value accepted is 22388 Hz. The value should<br />

also be one octave higher than the Minimum Frequency.<br />

Freq Min Edit Box<br />

Lets the user define the lowest Frequency of the Sweep. This is also the end<br />

measurement Frequency. The lowest value accepted is 10 Hz. The value should also<br />

be one octave lower than the Maximum Frequency.<br />

Gating (Acquisition) Settings<br />

Gated Check Box<br />

Lets user enable the gating acquisition mode. Checking it will automatically disable<br />

the Stepped Check Box and check it. That is, Gated Measurements are always carried<br />

in Stepped Mode.<br />

Delay Edit Box<br />

Lets user define the delay, in ms, applied between the signal generation and its<br />

acquisition. When different than 0 it is active, even when gating is not checked, if<br />

Chapter 11 - Sinusoidal 107