Download - Welotec
Download - Welotec
Download - Welotec
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
M30 Cylindrical<br />
Ultrasonic Sensor UT1<br />
<strong>Welotec</strong> GmbH<br />
Zum Hagenbach 7 • D-48366 Laer<br />
www.welotec.com • info@welotec.com<br />
Fon: +49 (0)2554/9130-00 • Fax: +49 (0)2554/9130-10
2/3<br />
Products<br />
M30<br />
with Teach-in button<br />
Series<br />
UT1<br />
M30<br />
with Teach-in button<br />
market sectors and applications<br />
construction equipments<br />
storage systems<br />
ceramic industry<br />
waste collecting systems<br />
general manufacturing
features<br />
M30 compact ultrasonic sensors with high performances and high sensing distances<br />
Models with adjustable digital output: models with two programmable outputs and with single output<br />
Adjustable hysteresis output: model with double digital programmable designed for level detection<br />
Models with voltage or current output: programmable slope to optimize resolution<br />
Adjustable working area (window mode or object mode) by Teach-in button on all models for a quick<br />
and easy installation<br />
Two multifunction LED indicators: Teach-in function and NO/NC selection (orange) and echo detection<br />
(green)<br />
Temperature compensation on all working range<br />
approvals<br />
protection degree<br />
IP67
4/5<br />
Products<br />
M30<br />
with Teach-in button<br />
UT1 M30 cylindrical Ultrasonic Sensor<br />
UT1 M30 ultrasonic sensor is a direct diffuse sensor with a working range from 250 mm to 3,500<br />
mm. The product has a compact plastic housing and it is available with both cable exit and M12<br />
plug exit. Through the Teach-in button it is possible to adjust the sensing distance, the output status<br />
(NO/NC) and the analogic output slope. Two LEDs visible through the transparent cable and plug<br />
holder, indicates the output, the Teach-in status (orange LED) and the echo detection (green LED),<br />
making easier the alignment with the target. All the UT1 family is temperature compensated, for<br />
granting a reliable detection on all temperature working range.<br />
pack content<br />
Installation manual (English + italian) : CAT8BUT1260401<br />
n° 2 plastic nuts<br />
n° 2 flexible washers<br />
further commercial and technical documents available<br />
Datasheet (Italian CAT3IUT1260401 and Spanish CAT3SUT1260601)<br />
High resolution pictures<br />
Application note:<br />
- coils distance detection (English: CAT3EUT1260801, Italian: CAT3IUT1260401<br />
and Spanish: CAT3SUT1261601)<br />
- filling level detection in silos for liquids and powders (English: CAT3EUT1261001,<br />
Italian: CAT3IUT1260901 and Spanish: CAT3SUT1261701)<br />
- presence and height detection of plants in agricultural machines (English: CAT3EUT1261201,<br />
Italian CAT3IUT1261101 and Spanish: CAT3SUT1261801)<br />
custom models already tested<br />
-<br />
minimum quantity that can be ordered<br />
1 piece
code description<br />
UT 1 B / E 1 - 0 E<br />
UL<br />
UT<br />
1<br />
B<br />
E<br />
1<br />
2<br />
P<br />
N<br />
W<br />
M<br />
5<br />
3<br />
6<br />
4<br />
7<br />
9<br />
0<br />
E<br />
A<br />
UL<br />
M30 ultrasonic sensor<br />
Standard body lenght<br />
250 - 3,500 mm direct diffuse<br />
Sensitivity adjustment and NO/NC selection by Teach-in button<br />
0...10 V single voltage analogue output (*)<br />
4...20 mA single current analogue output (*)<br />
PNP NO/NC single digital output (*)<br />
NPN NO/NC single digital output (*)<br />
PNP - NO/NC two digital outputs with standard window and adjustable hysteresis functions (**)<br />
NPN - NO/NC two digital outputs with standard window and adjustable hysteresis functions (**)<br />
PNP - NO/NC two digital outputs coded window output (***)<br />
NPN - NO/NC two digital outputs coded window output (***)<br />
PNP - NO/NC digital output + 4 ... 20 mA current analogue output (*)<br />
NPN - NO/NC digital output + 4 ... 20 mA current analogue output (*)<br />
PNP - NO/NC digital output + 0 ... 10 V voltage analogue output (*)<br />
NPN - NO/NC digital output + 0 ... 10 V voltage analogue output (*)<br />
Plastic housing<br />
M12 plug cable exit<br />
2 m PVC Axial cable exit<br />
with cULus certification<br />
(*)<br />
Sensing distance, NO/NC selection and analogue output slope adjustment takes possible by Teach-in button<br />
(**)<br />
The two functions switching is possible pressing the Teach-in button. The state choice may be done by logic reversing during the sensor check (e.g. PLC)<br />
(***)<br />
Specific model for detecting moving targets along the sensor axis<br />
models<br />
dimension<br />
function<br />
max.<br />
distance<br />
output<br />
analogue<br />
output<br />
0...10 V<br />
analogue<br />
output<br />
4...20 mA<br />
1 x<br />
PNP NO/NC<br />
1 X NPN<br />
NO/NC<br />
2 x PNP NO/NC<br />
(MD double<br />
coded output)<br />
2 x NPN NO/NC<br />
(MD double<br />
coded output)<br />
2 x PNP NO/<br />
NC (adjustable<br />
hysteresis MD<br />
stnd. window)<br />
2 x NPN NO/NC<br />
(adjustable<br />
hysteresis MD<br />
stnd. window)<br />
1 x PNP<br />
NO/NC<br />
+ 4...20 mA<br />
1 x NPN<br />
NO/NC<br />
+ 4...20 mA<br />
1 x PNP<br />
NO/NC<br />
+ 0...10 V<br />
1 x NPN<br />
NO/NC<br />
+ 0...10 V<br />
M30<br />
direct<br />
diffuse<br />
3.500<br />
mm<br />
M12<br />
plug<br />
cable<br />
UT1B/E1-0EUL UT1B/E2-0EUL UT1B/EP-0EUL UT1B/EN-0EUL UT1B/E5-0EUL UT1B/E3-0EUL UT1B/EW-0EUL UT1B/EM-0EUL UT1B/E6-0EUL UT1B/E4-0EUL UT1B/E7-0EUL UT1B/E9-0EUL<br />
UT1B/E1-0AUL UT1B/E2-0AUL UT1B/EP-0AUL UT1B/EN-0AUL UT1B/E5-0AUL UT1B/E3-0AUL UT1B/EW-0AUL UT1B/EM-0AUL UT1B/E6-0AUL UT1B/E4-0AUL UT1B/E7-0AUL UT1B/E9-0AUL
6/7<br />
Products<br />
M30<br />
with Teach-in button<br />
technical specifications<br />
according to IEC EN 60947-5-2 and IEC EN 60947-5-7<br />
models<br />
UT1B/E*-0*UL<br />
nominal sensing distance Sn<br />
minimum operating distance (blind zone)<br />
beam angle<br />
3,500 mm (1)<br />
250 mm<br />
12° ± 2°<br />
switching frequency (digital output)<br />
response time (digital output)<br />
differential travel H<br />
repeat accuracy<br />
linearity error<br />
operating temperature<br />
temperature compensation<br />
thermal drift of Sr<br />
rated operational voltage Ue<br />
maximum ripple content<br />
leakage current<br />
output voltage drop Ud<br />
No-Load supply current<br />
2 Hz<br />
250 ms<br />
0,5%<br />
0,2%<br />
0,5%<br />
-20° ...+70°C<br />
yes<br />
5%<br />
12 - 30 Vcc; 15 - 30 Vdc: voltage supply for<br />
voltage analogue output (0-10 V)<br />
5%<br />
≤ 10 µA (Vdc max)<br />
2.2 V max (IL=100mA)<br />
50 mA max<br />
maximum load current (digital output)<br />
minimum load resistance<br />
sensitivity adjustment<br />
supply electrical protections<br />
digital output electrical protections<br />
EMC<br />
electrical protections (analogue output)<br />
protection degree<br />
housing material<br />
active head material<br />
weight<br />
storage temperature<br />
100 mA<br />
3 k Ω (analogue voltage drop)<br />
Teach-in button<br />
polarity reversal, overvoltage pulses<br />
short circuit, overvoltage pulses<br />
Conforming to the EC Directive 2004/108/EC<br />
requirements according to EN 60947-5-2<br />
overvoltage pulses<br />
IP67 (EN 60529) NEMA 4X (2)<br />
PBT<br />
epoxy-glass resin<br />
90 g (plug exit) - 160 g (cable exit)<br />
-35°...+70°C (without freeze)<br />
(1)<br />
Metallic target 200 x 200 mm<br />
(2)<br />
Protection granted only by plug mounted in a correct way
2 Wh<br />
4 Bk<br />
3 Bu<br />
1 Bn Bn<br />
2 Wh<br />
1 Bn<br />
4 Bk 2<br />
Bk<br />
Wh<br />
3 Bu Bu<br />
4 Bk<br />
3 Bu<br />
+<br />
-<br />
Digital Output<br />
-<br />
B<br />
5 Gr<br />
3 Bu<br />
-/~<br />
A<br />
C<br />
BN<br />
BU<br />
BK<br />
WH<br />
M12<br />
M12<br />
Double Digital Output<br />
2 Wh<br />
NC NO<br />
4 Bk 2 Wh<br />
Digital Output NO<br />
2 1 3 2 4<br />
3 4<br />
1<br />
+ Light On<br />
Analog Output<br />
- Dark On<br />
+<br />
1 brown Bn<br />
1 Bn<br />
2 Wh<br />
blue<br />
2 Wh<br />
black<br />
4 Bk<br />
4<br />
white<br />
Bk<br />
4 Bk<br />
4 Bk Digital Output NC<br />
4 Bk<br />
NO NC<br />
Double Digital Output<br />
3 Bu<br />
-/~<br />
3 Bu<br />
3 Bu<br />
-/~<br />
-<br />
-<br />
1 Bn<br />
+<br />
Bn<br />
+<br />
+<br />
+ Teach & N.O - N.C.<br />
2 Wh + Light On<br />
+<br />
Wh Teach & N.O - N.C.<br />
1 Bn - Normal Operation<br />
- Dark On +<br />
- Normal Operation<br />
4 Bk<br />
4 Bk Bk Analog Output Digital Digital Output<br />
Output<br />
Digital Output<br />
3 Bu<br />
3 Bu<br />
-<br />
Bu<br />
3 Bu<br />
+ Light On<br />
2 Wh -<br />
- Dark On<br />
PNP NO/NC + analogue output<br />
3 Bu<br />
-<br />
-<br />
1 Bn<br />
+<br />
1 Bn 1 1 Bn Bn<br />
+ + +<br />
2 Wh<br />
2 Wh 4 Bk<br />
Digital Output<br />
1 Bn<br />
4 Bk<br />
Digital Output<br />
+<br />
4 Bk<br />
+ Light On<br />
4<br />
2 Wh<br />
Bk 2 Wh 2 Wh + Teach & N.O - N.C.<br />
Analog Output<br />
- Dark On<br />
- Normal Operation<br />
3 Bu<br />
3 Bu<br />
-<br />
3 3 Bu Bu<br />
4 Bk<br />
- - -<br />
Digital Output<br />
electrical A diagrams of connections<br />
models with PNP double double PNP output digital outputs<br />
3 Bu<br />
-<br />
+/~<br />
Digital out<br />
Supply (+)<br />
4<br />
1<br />
1 Bn1 Bn<br />
3<br />
2 Wh2 Wh<br />
1 Bn<br />
2<br />
4 Bk4 Bk<br />
2 Wh<br />
3 Bu3 Bu<br />
4 Bk<br />
UT1*/E4-0EUL<br />
Supply (-) + +/~<br />
UT1*/E6-0EUL<br />
Double Digital Output<br />
UT1*/E7-0EUL<br />
B<br />
D<br />
UT1*/E9-0EUL<br />
+<br />
Double Digital Output<br />
Analogue out<br />
- -/~<br />
NO NC<br />
1 Bn 1 Bn<br />
+<br />
1 Bn 1 Bn<br />
+<br />
+ +<br />
1 Bn<br />
1 Bn 1 Bn<br />
1 Bn<br />
+/~ +/~ +<br />
+<br />
2 Wh 2 Wh 4 Digital Output<br />
Common Bk<br />
2 Wh<br />
2 WhDouble digital output<br />
Digital Output<br />
Double Digital Output<br />
2 Wh 2 Wh<br />
NO<br />
1 Bn<br />
NC<br />
2 Wh<br />
Analogue Output output<br />
1 Bn<br />
+<br />
+/~<br />
4 Bk Digital Output NO<br />
4 Bk 2 Wh<br />
2 4 Wh Bk<br />
4 Bk Common<br />
Digital Output<br />
4 Bk<br />
2 Wh<br />
4 Bk<br />
4 Bk<br />
5 Gr<br />
Double Digital NC Digital<br />
Output<br />
NO output<br />
Analog Output<br />
Digital Output NC NO NC<br />
4 Bk Digital Double Output Digital NOOutput<br />
3 Bu 3 Bu<br />
- - B<br />
3 Bu 3 Bu<br />
3 Bu<br />
- -<br />
3 Bu<br />
3 Bu<br />
4 Bk 3 Bu<br />
-/~ -/~-<br />
-<br />
5 Gr<br />
Digital Output NC<br />
Double Digital Output<br />
-/~<br />
Digital out<br />
SP1<br />
Supply (+)<br />
4<br />
1<br />
3 Bu<br />
1 Bn<br />
2 Wh<br />
1 Bn<br />
3<br />
4 Bk<br />
2 Wh 1 Bn Bn<br />
2<br />
3 Bu<br />
4 Bk<br />
2 Wh Wh<br />
3 Bu 4 Bk Bk<br />
3 Bu Bu<br />
3 Bu<br />
-<br />
-<br />
models with PNP NO/NC single digital output<br />
1 Bn<br />
+<br />
3 4<br />
12 Bn Wh<br />
UT1*/E3-0EUL<br />
1 Bn<br />
+<br />
Supply +<br />
+<br />
check (-) +<br />
UT1*/E5-0EUL<br />
Double Digital Output<br />
check - E<br />
+<br />
2 Wh<br />
24 Wh Bk Teach & N.O - N.C.<br />
UT1*/EM-0EUL<br />
+<br />
1 Bn 1 Bn<br />
C<br />
- Normal Operation<br />
+ +<br />
UT1*/EW-0EUL<br />
+ Light On<br />
4 Bk<br />
43 4 Bk Bu<br />
-<br />
Bk<br />
Digital<br />
Output<br />
Output -<br />
4 Bk<br />
Digital Digital Output output<br />
Analog Output<br />
Analog - Dark Output On<br />
Digital out<br />
3 Bu<br />
3 Bu<br />
+ Light On -<br />
SP2 Digital Output -<br />
2 Wh -<br />
Digital Output<br />
2 Wh<br />
- Dark On<br />
--<br />
3 Bu 3 Bu<br />
- -<br />
+<br />
C<br />
3 Bu<br />
-/~<br />
models with single analogue output<br />
1 Bn 1 Bn<br />
21 Wh Bn<br />
42 Bk Wh<br />
4 Bk<br />
2 Wh<br />
34 Bu Bk 3 Bu<br />
3 Bu<br />
+ +<br />
Digital Output +<br />
+ Teach & N.O - N.C.<br />
Analogue - Normal Output output Operation<br />
- -<br />
Analog Output<br />
-<br />
+/~<br />
-/~<br />
Analogue out<br />
Digital out<br />
Supply (+)<br />
4<br />
1<br />
1 Bn<br />
+<br />
Supply (-)<br />
1 Bn Double Digital Output<br />
2 Wh<br />
1 Bn<br />
3<br />
4 Bk<br />
4 Bk 2 Wh<br />
2<br />
2 Wh<br />
3 Bu<br />
4 Bk n.c. Digital Output -<br />
NO NC<br />
3 Bu<br />
3 Bu<br />
UT1*/E1-0EUL<br />
-<br />
-<br />
F<br />
D<br />
UT1*/E2-0EUL<br />
+<br />
UT1*/EP-0EUL<br />
+<br />
UT1*/EN-0EUL<br />
Double Digital Output<br />
Analog Output<br />
NPN NO/NC models + analogue output<br />
1 Bn<br />
1 Bn<br />
+<br />
+<br />
2 Wh<br />
4 Bk<br />
12 Bn Wh<br />
1 Bn<br />
+<br />
Analog Output<br />
24 Wh Bk<br />
2 Wh<br />
Digital<br />
Digital<br />
output<br />
Output<br />
NC Digital Output NO<br />
Double Digital Output<br />
3 Bu<br />
43 Bk Bu<br />
4 Bk<br />
-<br />
Analogue Output output<br />
-<br />
Double Digital Output<br />
3 Bu<br />
3 Bu<br />
-<br />
-<br />
D<br />
models with NPN double digital outputs<br />
1 Bn<br />
1 Bn<br />
+<br />
+<br />
2 Wh1 Bn<br />
4 Bk2 Wh<br />
Double<br />
4 Bk<br />
Digital Output Digital Output<br />
+<br />
2 Wh<br />
Analog Output<br />
3 Bu4 Bk<br />
3 Bu<br />
-<br />
-<br />
Double<br />
Double<br />
digital<br />
Digital<br />
output<br />
Output<br />
3 Bu<br />
-<br />
models with NPN NO/NC single digital output<br />
1 Bn<br />
21 Wh Bn<br />
42 Bk Wh<br />
Double Digital Output<br />
+<br />
+<br />
E<br />
1 Bn<br />
4 Bk<br />
Digital output Output<br />
+<br />
E<br />
34 Bu Bk<br />
Digital Output<br />
-<br />
2 Wh<br />
3 Bu<br />
-<br />
3 Bu<br />
-<br />
1 Bn<br />
2 Wh<br />
+<br />
Analog Output<br />
F<br />
1 Bn<br />
4 Bk<br />
Digital Output<br />
+<br />
F<br />
4 Bk<br />
Digital Output<br />
2 Wh<br />
Analog Output<br />
3 Bu<br />
-<br />
3 Bu<br />
-
8/ 9<br />
Products<br />
M30<br />
with Teach-in button<br />
response diagram<br />
UT1B/**-**<br />
parallel displacement (mm)<br />
distance (mm)<br />
NO<br />
Sensore<br />
Sensor<br />
available outputs<br />
OUT<br />
P1 P2 mm<br />
NO<br />
Sensore<br />
models with single digital output<br />
OUT<br />
NC<br />
P1 P2 mm<br />
Sensor<br />
Sensore<br />
Sensor<br />
OUT<br />
OUT<br />
NO<br />
NO<br />
P1 P2 mm<br />
P1 P2 mm<br />
Sensore<br />
Sensore<br />
Sensor<br />
OUT<br />
V<br />
10<br />
OUT<br />
P1 P2 mm<br />
NC<br />
V<br />
NO<br />
10<br />
P1 P2 mm<br />
NC<br />
Sensore<br />
Sensor<br />
models with single analogue output<br />
NC<br />
NC<br />
OUT<br />
OUT<br />
P1 P2 mm<br />
P1 P2 mm<br />
V<br />
V<br />
V<br />
NO<br />
V<br />
NO<br />
10<br />
10<br />
NO<br />
10<br />
10<br />
H<br />
H<br />
Sensore<br />
Sensore<br />
Sensor<br />
V<br />
0<br />
10<br />
0<br />
NC<br />
NC<br />
SP1<br />
SP1<br />
V<br />
NO<br />
0<br />
NC<br />
P1 P2 mm<br />
P1<br />
P2<br />
mm<br />
10<br />
NO<br />
0<br />
P1 P2 mm<br />
P1<br />
P2<br />
mm<br />
Sensore<br />
mm<br />
Sensor<br />
NO<br />
0<br />
0<br />
SP2<br />
0<br />
SP2<br />
L<br />
P1 P2 mm 0<br />
P1<br />
P2<br />
mm<br />
P1 P2 mm mm<br />
P1 Sensore<br />
P2<br />
mm<br />
H<br />
Sensor<br />
L<br />
SP2<br />
models with digital output + analogue output (*)<br />
L<br />
L<br />
SP1 SP1<br />
NO<br />
P1 P2 mm<br />
SP2<br />
SP1<br />
NO<br />
NO<br />
P1 P2 mm<br />
H<br />
H<br />
mm<br />
mm<br />
NC<br />
H<br />
P1 P2 mm<br />
Sensore<br />
Sensor<br />
Sensore<br />
Sensor<br />
H<br />
H<br />
L<br />
SP2<br />
Sensore<br />
SP1<br />
SP1<br />
mm<br />
Sensore<br />
L<br />
L<br />
mm<br />
Sensor<br />
SP2<br />
mm<br />
H<br />
SP2<br />
Sensore<br />
H<br />
H<br />
Sensor<br />
SP2<br />
SP2<br />
L<br />
SP2<br />
P1 P2 mm<br />
SP1<br />
L P1 L P2 mm<br />
SP1<br />
P1 P2 mm<br />
SP2<br />
models with double output, hysteresis + standard window (**) L<br />
SP1 L<br />
SP1<br />
NC<br />
NO<br />
NC<br />
H<br />
H<br />
H<br />
SP2<br />
SP1<br />
Sensore<br />
SP1 L<br />
mm<br />
SP2<br />
Sensore<br />
mm<br />
mm<br />
Sensor<br />
SP2<br />
Sensore<br />
SP2<br />
H<br />
Sensor<br />
L<br />
SP2<br />
L P1 L P2 mm<br />
L<br />
SP1<br />
SP1<br />
P1 P1 P2 P2 mm mm<br />
L<br />
SP1<br />
H<br />
NC<br />
models SP2 with double digital output, coded window (***)<br />
NO<br />
L<br />
L<br />
H<br />
H mm<br />
H<br />
L<br />
Sensore<br />
SP2<br />
SP2<br />
H<br />
H<br />
SP1<br />
Sensor<br />
SP2<br />
L<br />
L<br />
mm<br />
Sensore<br />
P1 P2 H mm<br />
Sensor<br />
H<br />
SP1 L<br />
SP1<br />
L<br />
L<br />
SP1<br />
P1 P2 mm<br />
L<br />
P1 P2 mm<br />
NO<br />
mm<br />
H<br />
H<br />
H NC<br />
L<br />
L<br />
P1 P2 mm<br />
mm<br />
mm<br />
H<br />
H<br />
L<br />
L<br />
P1 P2 mm<br />
P1 P2 mm<br />
P1 P2 mm<br />
H<br />
NO<br />
L<br />
L<br />
H<br />
H mm<br />
H<br />
H<br />
L<br />
mm<br />
P1 P2 H mm<br />
L<br />
P1 P2 mm<br />
NO<br />
H<br />
H<br />
NC<br />
mm<br />
L<br />
H L<br />
mm<br />
H<br />
L<br />
P1 P2 mm<br />
L<br />
P1 P2 mm<br />
Sensore<br />
Sensor<br />
Sensore<br />
Sensore<br />
Sensor<br />
Sensor<br />
Sensore<br />
Sensor<br />
Sensore<br />
Sensor<br />
Sensore<br />
Sensor<br />
Sensore<br />
Sensor<br />
(*)<br />
Suitable, also, as single model output.<br />
(**)<br />
In the double digital output model with the standard window<br />
and adjustable hysteresis functions if the target is removed<br />
from sensor detection range, the output state switches.<br />
These models are not forseen with NO/NC function, which<br />
can be obtained through a logic reverse by control system<br />
(e.g. PLC)<br />
(***)<br />
The double digital output model with the coded window<br />
is, particularly, designed for the target detection, moving<br />
along the longitudinal axis sensor: even removing the target,<br />
the sensor remains in the last stored ouput state, not receiving<br />
any echoes.<br />
SP2<br />
H<br />
H<br />
SP2<br />
H<br />
NC
dimensions<br />
UT1B/**-** (cable)<br />
ø 8<br />
orange LED<br />
multifunction button<br />
green LED<br />
69.6<br />
tightening plastic nut<br />
(92.5)<br />
cable exit<br />
6.1<br />
6.4<br />
3<br />
ø 4.7<br />
13<br />
SW 36<br />
mm<br />
89.5<br />
3<br />
UT1B/**-** (plug)<br />
orange LED<br />
multifunction button<br />
69.6<br />
(92.5)<br />
plug exit<br />
ø 8<br />
6.4<br />
green LED<br />
6.1<br />
M 30 x 1.5<br />
M 30 x 1.5<br />
M 12 x 1<br />
13<br />
3<br />
SW36<br />
89.5<br />
10<br />
mm<br />
accessories<br />
code<br />
ST 13<br />
ST 14<br />
ST 30-A<br />
ST 30-C<br />
ST 30-D-U<br />
ST 30-D-U-F<br />
ST 55-U<br />
CD12/0B-***A1US<br />
CD12/0B-***C1US<br />
CD12/0B-***A5US<br />
CD12/0B-***C5US<br />
description<br />
Metal swing bracket with threaded holes for M30 ultrasonic sensors. Mounting with<br />
M6 screws from beneath the surface or through the wall<br />
Plastic swing bracket for M30 ultrasonic sensor. Mounting with M6 screws from upper side<br />
Metal axial mount bracket for M30 ultrasonic sensors. Mounting with M5 screws<br />
Metal right angle mount bracket for M30 ultrasonic sensors. Mounting with M5 screws<br />
Beam deflector bracket for M30 ultrasonic sensors<br />
Focusing beam deflector bracket for M30 ultrasonic sensors<br />
Plastic M30 ultrasonic sensors beam deflector<br />
Connectors with PVC cable and cCSAus certification. Axial<br />
Connectors with PVC cable and cCSAus certification. Radial<br />
Connectors with PUR cable and cCSAus certification. Axial<br />
Connectors with PUR cable and cCSAus certification. Radial<br />
***= 050 (5 m) / ***= 100 (10 m) / ***= 150 (15 m)
Bustius quidit alisto volupid min naturi<br />
Our entire program is available on the Internet at www.welotec.com<br />
<strong>Welotec</strong> GmbH<br />
Zum Hagenbach 7 • D-48366 Laer • Fon: +49 (0)2554/9130-00<br />
Fax: +49 (0)2554/9130-10 • info@welotec.com