Product Information<br />
<strong>Miele</strong> – Integrated cooker hoods<br />
Model number<br />
Hood type<br />
Hous<strong>in</strong>g unit/cut-out dimensions<br />
Height<br />
mm<br />
Width<br />
mm<br />
Depth<br />
mm<br />
Appliance dimensions<br />
Height (excl. duct<strong>in</strong>g connection)<br />
mm<br />
Width (cas<strong>in</strong>g/deflector plate)<br />
mm<br />
Depth (with deflector plate retracted) 1 )<br />
mm<br />
Depth with deflector plate pulled out 1 )<br />
mm<br />
Net weight 2 )<br />
kg<br />
Net weight EXT 2 )<br />
kg<br />
M<strong>in</strong>imum safety distance<br />
Electric hob<br />
mm<br />
Gas hob, open grill, deep-fat fryer<br />
mm<br />
Versions available<br />
Extraction<br />
Recirculation<br />
External motor<br />
Controls<br />
On/Off when deflector/canopy operated<br />
Light switch/with LED<br />
On/Off/with LED<br />
Slid<strong>in</strong>g switch for power levels<br />
Sensor switch for power levels<br />
Plus/M<strong>in</strong>us power level control with LED<br />
Joystick controls<br />
Rotary switch for light<strong>in</strong>g, on/off and power levels<br />
5–15 m<strong>in</strong> run on<br />
Check grease filter<br />
Check charcoal filter<br />
Features<br />
Flourescent tube light<strong>in</strong>g<br />
W<br />
Uplighters<br />
W<br />
Halogen light<strong>in</strong>g/with dimmer function<br />
W<br />
LED feature light<strong>in</strong>g<br />
Double act<strong>in</strong>g radial fan<br />
Sta<strong>in</strong>less steel grease filters<br />
Non return flap<br />
Duct<strong>in</strong>g diameter<br />
mm<br />
Number of fan sett<strong>in</strong>gs<br />
Includ<strong>in</strong>g Intensive sett<strong>in</strong>g 3 )<br />
Automatic switch off of Intensive sett<strong>in</strong>g after 10 m<strong>in</strong><br />
Extraction rate per hour 4 )<br />
200 mm diameter duct<strong>in</strong>g m 3<br />
150 mm diameter duct<strong>in</strong>g m 3<br />
125 mm diameter duct<strong>in</strong>g m 3<br />
120 mm diameter duct<strong>in</strong>g m 3<br />
100 mm diameter duct<strong>in</strong>g m 3<br />
Recirculation m 3<br />
Unrestricted m 3<br />
Noise level db (re1pw) 5 )<br />
200 mm diameter duct<strong>in</strong>g db<br />
150 mm diameter duct<strong>in</strong>g db<br />
125 mm diameter duct<strong>in</strong>g db<br />
120 mm diameter duct<strong>in</strong>g db<br />
100 mm diameter duct<strong>in</strong>g db<br />
Recirculation<br />
db<br />
Electrical connection<br />
Length of cable (EXT <strong>in</strong> brackets)<br />
cm<br />
Voltage<br />
V<br />
Total connected load<br />
W<br />
Fuse rat<strong>in</strong>g<br />
A<br />
Radio/TV suppressed<br />
Ma<strong>in</strong>s <strong>in</strong>terference suppressed<br />
Operat<strong>in</strong>g/Installation <strong>in</strong>structions<br />
DA 3160 DA 3190 DA 2050<br />
Integrated Integrated Integrated<br />
m<strong>in</strong>. 430 m<strong>in</strong>. 430 –<br />
562–568 862–8686) 500<br />
295–350 295–350 340<br />
379 379 283<br />
500/595 500/895 532<br />
275 275 372<br />
425 425 –<br />
12 14 8<br />
– – –<br />
450 450 450<br />
650 650 650<br />
l l l<br />
l l l<br />
– – –<br />
l l –<br />
l/l l/l –<br />
l/l l/l –<br />
– – –<br />
– – –<br />
l l –<br />
– – –<br />
– – l<br />
– – –<br />
– – –<br />
– – –<br />
– – –<br />
– – –<br />
2 x 50/– 2 x 50/– 2 x 50/–<br />
– – –<br />
1 1 l<br />
1 2 1<br />
l l l<br />
125/150 125/150 125/150<br />
4 4 3<br />
l l l<br />
l l –<br />
– – –<br />
150–550 150–550 150–400<br />
140–520 140–520 140–380<br />
– – –<br />
– – –<br />
80–350 80–350 120–360<br />
550 550 400<br />
– – –<br />
45–64 45–64 42–65<br />
46–65 46–65 43–66<br />
– – –<br />
– – –<br />
53–73 53–73 44–65<br />
150 150 150<br />
230 230 230<br />
280 280 290<br />
5 5 5<br />
l l l<br />
l l l<br />
l l l<br />
DA 2170<br />
Integrated<br />
–<br />
670<br />
370<br />
280<br />
–<br />
–<br />
–<br />
9<br />
–<br />
450<br />
650<br />
l<br />
l<br />
–<br />
–<br />
l/l<br />
–<br />
–<br />
–<br />
l<br />
l<br />
–<br />
l<br />
l<br />
l<br />
–<br />
–<br />
2 x 50<br />
l<br />
l<br />
2<br />
l<br />
125/150<br />
4<br />
l<br />
l<br />
150–500<br />
130–450<br />
–<br />
–<br />
120–400<br />
550<br />
550<br />
–<br />
43–63<br />
44–64<br />
–<br />
–<br />
47–67<br />
150<br />
230<br />
220<br />
5<br />
l<br />
l<br />
l<br />
l = standard feature<br />
1<br />
) Excludes depth of optional lightshield<br />
2<br />
) Take care to ensure that <strong>the</strong> unit, wall or ceil<strong>in</strong>g can bear <strong>the</strong> weight of <strong>the</strong> appliance<br />
3<br />
) Short term higher extraction performance, accompanied by higher noise level<br />
4<br />
) Air throughput accord<strong>in</strong>g to EN 61591. For EXT models <strong>the</strong> connected load and extraction power will vary depend<strong>in</strong>g on <strong>the</strong> type of external motor fitted<br />
5<br />
) Noise levels measured <strong>in</strong> acc. With EN 60704-2-13 and EN 60704-3<br />
6<br />
) These extractors can also be fitted <strong>in</strong> a 600 mm wide unit<br />
7<br />
) Depend<strong>in</strong>g on build<strong>in</strong>g-<strong>in</strong> situation<br />
N.B. These appliances conform to <strong>Euro</strong>pean safety regulations and must be <strong>in</strong>stalled <strong>in</strong> accordance with IEE regulations by a competent person<br />
126