Bluetooth Commands - wless.ru
Bluetooth Commands - wless.ru
Bluetooth Commands - wless.ru
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
IL – Last Inquiry........................................................34<br />
Inpair by Index - UPAIR ...........................................41<br />
Inquire – DI ..............................................................33<br />
L<br />
LAST – Read Last Address......................................36<br />
Last Inquiry – IL........................................................34<br />
Link Supervisory Timeout - LSTO ............................47<br />
Lock User Settings - SW26 ......................................31<br />
LQ – Get Link Quality...............................................45<br />
LQC – Get Link Quality by Channel .........................45<br />
LSTO – Link Supervisory Timeout ...........................47<br />
M<br />
MACLR – Master Address Clear..............................37<br />
Master Address Clear – MACLR..............................37<br />
MD – Put Device into Data Mode .............................40<br />
MF – Put Device inot Fast Data Mode .....................40<br />
Move to FTP Parent Directory – FTPUP ..................52<br />
Move to FTP Root Directory – FTPROOT................52<br />
Move to FTP Sub Directory – FTPSUB....................52<br />
Multi-Point (MP) Architecture ...................................10<br />
Multi-Point Example ...........................................64, 66<br />
O<br />
Object Push – OPPPUSH ........................................57<br />
OP - Overwrite PIN ..................................................25<br />
OPP client................................................................55<br />
OPP Server Receive Business Card Example Using<br />
Broadcom Stack...................................................58<br />
OPP Server Send Business Card Example Using<br />
Broadcom Stack...................................................58<br />
OPP Server Send Data Example Using TransSend.59<br />
OPPPUSH – Object Push ........................................57<br />
Overwrite PIN - OP ..................................................25<br />
P<br />
PAIR – Pair Devices.................................................41<br />
Pair Devices - PAIR .................................................41<br />
PARK – Enable Park................................................44<br />
Power Consumption Class 1....................................82<br />
PR – Respond to Manual PIN Request....................25<br />
Protocol V2.0..............................................................7<br />
Put Device into Command Mode - +++ ....................39<br />
Put Device into Data Mode - MD..............................40<br />
Put Device into Fast Data Mode - MF ......................40<br />
R<br />
RBCARD – Business Card Pull................................56<br />
READ – Read Variable ............................................47<br />
Read Auto Connect Master on Data – RSW7 ..........37<br />
Read Bypass for Factory Config – RSW 0 ...............16<br />
Read Last Address - LAST ......................................36<br />
Read Max Connection Number – RSW 3.................21<br />
Read PIN Request Handling Mode - RSW 6............24<br />
Read PIO Level – SR21...........................................33<br />
Read PIO Logic – RSW4 .........................................48<br />
Read Remote Radio Name by BT Address - RRN...22<br />
Read Remote Service Name - RRSN ......................23<br />
Read Service Name - RSN ......................................23<br />
Read Service Name by Channel - RSNC.................23<br />
Read Variable - READ .............................................47<br />
Repeater Example ...................................................68<br />
Repeater Mode ........................................................14<br />
Reset - URST...........................................................16<br />
Responde to manual PIN Request - PR...................25<br />
RRN – Read Remote Radio Name by BT Address ..22<br />
Index<br />
RRSN – Read Remote Service Name .....................23<br />
RSN – Read Service Name .....................................23<br />
RSNC – Read Service Name by Channel................23<br />
RSSI – Get RSSI Value ...........................................44<br />
RSSIC – Get RSSI Value by Channel......................45<br />
RSW 0 – Read Bypass for Factory Config ...............16<br />
RSW 2 – Get Security Level ....................................21<br />
RSW 3 – Read Max Connection Number.................21<br />
RSW 6 – Read PIN Request Handling Mode...........24<br />
RSW4 – Read PIO Logic .........................................48<br />
RSW7 – Read Auto Connect Master on Data ..........37<br />
S<br />
SBCARD – Business Card Push..............................56<br />
SC - Class of Device ................................................25<br />
SDIS – Set Discoverable..........................................49<br />
Select Transmission Channel – SWC ......................48<br />
SESC – Set Escape Character ................................39<br />
Set Master Default Address - SMA .........................37<br />
Set Auto Connect Master on Data – SSW7 .............37<br />
Set Bypass for Factory Config – SSW 0 ..................16<br />
Set Discoverable – SDIS..........................................49<br />
Set Escape Character - SESC .................................39<br />
Set Max Number of BT Connections – SSW 3.........21<br />
Set Max TX Power Level - SPF................................46<br />
Set PIN - SP.............................................................24<br />
Set PIN Request Handling Mode - SSW 6 ...............24<br />
Set PIO Logic – SSW4.............................................48<br />
Set Security Level – SSW 2 .....................................21<br />
Set Service Name - SSN..........................................22<br />
Set Service Name by Channel - SSNC ....................23<br />
Set SocketWireless Name - SN ...............................22<br />
Set Undiscoverable – UDIS .....................................49<br />
Short Response Mode St<strong>ru</strong>cture..............................74<br />
SI – Status Information.............................................17<br />
SMA - Set Master Default Address ..........................37<br />
SN - Set SocketWireless Name ...............................22<br />
SNIFF – Enable Sniff ...............................................42<br />
Sniff and Low Power Modes ....................................42<br />
SP – Set PIN............................................................24<br />
SPF – Set Max TX Power Level...............................46<br />
SR21 - Read PIO Level............................................33<br />
SSN - Set Service Name..........................................22<br />
SSNC - Set Service Name by Channel ....................23<br />
SSNIFF – Enable Auto Sniff.....................................43<br />
SSW 0 – Set Bypass for Factory Config ..................16<br />
SSW 2 – Set Security Level .....................................21<br />
SSW 3 – Set Max Number of BT Connections.........21<br />
SSW 6 – Set PIN Request Handling Mode ..............24<br />
SSW4 – Set PIO Logic.............................................48<br />
SSW7 – Set Auto Connect Master on Data .............37<br />
Status Information - SI .............................................17<br />
STORE – Store Variable ..........................................47<br />
Store Variable - STORE...........................................47<br />
SW20 – Write UART Settings ..................................26<br />
SW21 – Write Slave Scan Intervals and Windows ...27<br />
SW22 – Write PIO Direction.....................................28<br />
SW23 – Write PIO Level ..........................................29<br />
SW24 – Write Response, Security, Auto SCO, Filter<br />
Settings ................................................................29<br />
SW25 – Write Connection, Comm, Unconnected<br />
UART, Default Services Modes............................30<br />
SW26 - Lock User Settings ......................................31<br />
SW27 – Write LED Rate} .........................................31<br />
SW28 – Write Inquiry and Master Timeout Settings}31<br />
SW29– Write PIN Lock Mode} .................................32<br />
SW30 – Write Deep Sleep Mode} ............................32<br />
SWC – Select Transmission Channel ......................48<br />
Multi-Tech Systems, Inc. SocketWireless <strong>Bluetooth</strong> AT <strong>Commands</strong> (S000360G) 89