Autoriv Installation <strong>Systems</strong><br />

Autoriv 100 System – Technical Data<br />

Rated current:<br />

Rated voltage:<br />

Frequency:<br />

10 amp<br />

115V (24V Control Voltage)<br />

60Hz<br />

Fuse protection: 12.5A<br />

Number of phases: 1<br />

Compressed air supply:<br />

Pressure control device:<br />

Air-borne noise:<br />

Machine dimensions: Height: 1500mm (59")<br />

Width: 1100mm (42.3")<br />

Length: 1450mm (57")<br />

Weight:<br />

Service pressure ....................................................................................................6 bar (80 psi)<br />

Air requirements .................100m3/h (59cfm) (2 out) to 200 m3/h (118cfm) (4 out)<br />

Quality ..................................................................................................................................oil-free<br />

Connection .......................................................................................................................1/2 inch<br />

Factory setting .................................................. Switch-on pressure ≥ 5.3 bar (76.9 psi)<br />

Factory setting ............................................... Switch-off pressure ≤ 4.5 bar (65.26 psi)<br />

Measuring process ....................................................................... In-process measurement<br />

Measuring device ................................................................................................... DIN IEC 651<br />

Measuring code .....................................................................................................DIN 45645-2<br />

External noise ...................................................................................... Automatic conditions<br />

Measuring point ................................................. Using position, 1.5m above floor level<br />

Measuring distance 1m, cover closed:<br />

Sm .............................................................. Min: 75.9 dB(A), Max: 86.3 dB(A), Ø 81.1dB(A)<br />

Measuring distance 1m, cover open:<br />

Sm ............................................................Min: 75.9 dB(A), Max: 102.3 dB(A), Ø 89.1dB(A)<br />

Measuring distance >3m, cover open:<br />

Sm ....................................................................................................................................