Rivtex® <strong>Fastening</strong> <strong>Systems</strong><br />

<strong>Clinch</strong> Bolts: Type TCB<br />

D t<br />

Rivtex Studs Dimensional & Performance Data – Metric Sizes (all dimensions shown in millimeters)<br />

Thread<br />

Size<br />

D<br />

(-0.27)<br />

Dt<br />

(± 0.15)<br />

Dr<br />

(-0.2)<br />

R<br />

(+0.2, -0.1)<br />

C<br />

(±0.13)<br />

M5 x 0.8 9 8.3 5.35 0.9 1.8<br />

M6 x 1.0 12 11.0 6.35 1.0 2.1<br />

M8 x 1.25 16 14.5 8.50 1.2 2.8<br />

M10 x 1.5 20 18.0 10.50 1.3 3.5<br />

Material<br />

Thickness<br />

0.75<br />

Recommended<br />

Hole Size<br />

Staking<br />

Force<br />

kN<br />

45<br />

Approx.<br />

Pushout<br />

kN<br />

Approx. Unsupported<br />

Torsional Resistance<br />

Nm<br />

1.5 5.35 (+0.1) 55 *Application testing is required.<br />

2.0 65<br />

0.75<br />

45 1.1 10.0<br />

1.5 6.35 (+0.1) 55 1.7 15.0<br />

2.0 65 2.1 15.0<br />

0.8<br />

65 1.3 13.0<br />

1.5 8.50 (+0.15) 85 2.1 30.0<br />

2.0 100 2.6 35.0<br />

1.0<br />

95<br />

1.5 10.5 (+0.15) 95 *Application testing is required.<br />

2.5 120<br />

Sizes M5 and M10 require application testing to determine specific performance data.<br />

Underhead shape and dimensions controlled by manufacturer to meet performance requirements.<br />

Performance data shown above are typical results obtained under laboratory conditions. It is recommended that each application be tested<br />

individually for precise values. For performance in materials other than steel, individual testing is a requirement. This data is not to be<br />

considered a specification.<br />

Contact an Acument Global Technologies applications engineer for assistance.<br />