500 DVE 03 Digital Power Amplifier - Industronic
500 DVE 03 Digital Power Amplifier - Industronic
500 DVE 03 Digital Power Amplifier - Industronic
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>500</strong> <strong>DVE</strong> <strong>03</strong><br />
<strong>Digital</strong> <strong>Power</strong> <strong>Amplifier</strong> 2 x 250 W 100 V<br />
Main features<br />
<br />
<br />
<br />
<br />
<br />
2 x 250 W continuous output<br />
Advantages by the digital power stage:<br />
- Especially high efficiency<br />
- Low emergency power consumption<br />
- High power density<br />
48 and 60 VDC emergency supply<br />
Temperature-controlled fan<br />
Integrated amplifier monitoring functions:<br />
- Functioning<br />
- Short-circuit<br />
- Excess temperature<br />
- Voltage failure<br />
The <strong>500</strong> <strong>DVE</strong> <strong>03</strong> digital power amplifier is a part of the INDUSTRONIC communication and public address system with<br />
digital interfaces. It provides two amplifier units which can be addressed independently from each other. The amplifier<br />
provides integrated monitoring functions and is especially designed for use in warning and alarm systems according to<br />
the standard DIN EN 60849 respectively VDE 0828.<br />
Components Stable sheet steel case<br />
<br />
<br />
<br />
Solid power supply<br />
2 digital power stages<br />
2 digital interfaces<br />
Optional Also available for 115 VAC<br />
(see <strong>500</strong> <strong>DVE</strong> <strong>03</strong>/120, no. 304-122-300/120)<br />
<br />
<br />
1-channel version with 1 x 250 W output power<br />
(see 250 <strong>DVE</strong> <strong>03</strong>, no. 304-121-300)<br />
Zone selector (16 DCI 01, 3 DRU 0x) to distribute the amplifier output to<br />
several loudspeaker groups<br />
Doc. No. DAT-304-122-300 • Rev. 1 • US • 25.08.2011<br />
© INDUSTRONIC 1 / 3<br />
Subject to technical modifications
+Ub<br />
<br />
Fan<br />
Figure 1: Block diagram <strong>500</strong> <strong>DVE</strong> <strong>03</strong><br />
Electrical data Output power 2 x 250 W at 1 kHz sine wave<br />
Efficiency at rated power >80%<br />
Distortion 80 dB<br />
Frequency response 200 Hz to 15 kHz +/-3 dB<br />
AF input 0.4 to 2 V eff<br />
Treble +/-6 dB, 10 kHz<br />
Bass +/-6 dB, 250 Hz<br />
Operating voltage 230 VAC +/-15%<br />
Emergency power 42 VDC to 72 VDC<br />
<strong>Power</strong> consumption (mains) Quiescent 10 VA<br />
Nominal power 620 VA<br />
Current consumption 60 V Quiescent 0.1 A<br />
Nominal power 10 A<br />
Fuses Mains supply 4 A M<br />
Emergency supply (internal) 2 x 8 A T<br />
Doc. No. DAT-304-122-300 • Rev. 1 • US • 25.08.2011<br />
© INDUSTRONIC 2 / 3<br />
Subject to technical modifications
Mechanical data Design 19 “ slide-in chassis, 2 RU<br />
Height x width x depth 88 mm x 430 mm x 275 mm<br />
(3 1 /2" x 17" x 11")<br />
Dimensions of the front plate 483 mm (19"), 2 RU<br />
Installation depth approx. 330 mm (approx. 13")<br />
Weight approx. 12,5 kg (approx. 27 1 /2 lb)<br />
Environmental requirements and<br />
standards<br />
<br />
<br />
Ambient temperature during<br />
operation<br />
Relative humidity<br />
(non condensing)<br />
-5 °C to +50 °C (23 °F to 122 °F)<br />
max. 95 %<br />
EMC IEC / EN 61000-6-2<br />
IEC / EN 61000-6-4<br />
<br />
Sound Systems for Emergency<br />
Purposes<br />
DIN EN 60849 respectively VDE 0828<br />
INDUSTRONIC ® Inc.<br />
1011 US Highway 22 West<br />
Suite 301<br />
Bridgewater, NJ 08876, USA<br />
Tel. +1 908 393-5960<br />
Fax: +1 908 393-5961<br />
contact@industronic.com<br />
www.industronic.com<br />
Doc. No. DAT-304-122-300 • Rev. 1 • US • 25.08.2011<br />
© INDUSTRONIC 3 / 3<br />