27.01.2014 Views

KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1 Summary<br />

1.1 Preliminary remark<br />

The <strong>test</strong>s have be<strong>en</strong> passed <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong>. Main<br />

purpose for <strong>test</strong>ing has be<strong>en</strong>, <strong>to</strong> fulfill all requirem<strong>en</strong>ts for the<br />

SolarKeymark label. All requirem<strong>en</strong>ts have be<strong>en</strong> met.<br />

The pres<strong>en</strong>t report is valid for the collec<strong>to</strong>r series Collet<strong>to</strong>re Solare Piano<br />

CP4M , Collet<strong>to</strong>re Solare Piano CP4L, Collet<strong>to</strong>re Solare Piano CP4XL<br />

and the collec<strong>to</strong>r series Collet<strong>to</strong>re Solare Piano CP2M , Collet<strong>to</strong>re Solare<br />

Piano CP2L, Collet<strong>to</strong>re Solare Piano CP2XL . The <strong>test</strong>s were performed at<br />

the largest collec<strong>to</strong>r and at the smallest collec<strong>to</strong>r of the series, <strong>according</strong> <strong>to</strong><br />

the rules of the SolarKeymark (Version 8.00 of January 2003).<br />

Alike the certificate of the collec<strong>to</strong>r minimum gain of 525 kwh/m 2 a is<br />

handed.<br />

1.2 <strong>Collec<strong>to</strong>r</strong> effici<strong>en</strong>cy parameters determined<br />

Results:<br />

The calculated parameters are based on following areas:<br />

aperture area of 1.924 m 2 : absorber area of 1.840 m 2 :<br />

η 0a = 0.759 η 0A = 0.794<br />

a 1a = 3.480 W/m 2 K a 1A = 3.639 W/m 2 K<br />

a 2a = 0.0161 W/m 2 K 2 a 2A = 0.0168 W/m 2 K 2<br />

1.3 Incid<strong>en</strong>ce angle modifier - IAM<br />

θ: 0 ◦ 10 ◦ 20 ◦ 30 ◦ 40 ◦ 50 ◦ 60 ◦ 70 ◦ 80 ◦ 90 ◦<br />

K θ : 1.00 1.00 1.00 0.99 0.98 0.95 0.89 0.76 0.50 0.00<br />

Table 1: Measured (bold) and calculated IAM data for Collet<strong>to</strong>re Solare Piano CP4M<br />

1.4 Pressure drop<br />

The pressure drop in mbar can be described by the following function of<br />

the mass flow x in kg/h:<br />

∆p = 0.005 ∗ x + 1.187 ∗ 10 −5 ∗ x 2 (1)<br />

<strong>KTB</strong> <strong>Nr</strong>. <strong>2006</strong>-<strong>35</strong>-k-j-<strong>en</strong> : <strong>Collec<strong>to</strong>r</strong> <strong>test</strong> <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong><br />

IMMERGAS S.p.A. , Series Collet<strong>to</strong>re Solare Piano CP4M and Collet<strong>to</strong>re Solare Piano CP2M<br />

04.07.2007, Fraunhofer-ISE, Heid<strong>en</strong>hofstraße 2, D-79110 Freiburg<br />

Page 5 of 37