27.01.2014 Views

KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

E.2 Effici<strong>en</strong>cy curve<br />

1<br />

0.9<br />

Effici<strong>en</strong>cy η (based on aperture area)<br />

0.8<br />

0.7<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

0.2<br />

0.1<br />

0<br />

-0.01 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1<br />

Δt/G [K*m 2 /W]<br />

Figure 10: Effici<strong>en</strong>cy curve with measurem<strong>en</strong>t points based on aperture area 1.924 m 2<br />

Results:<br />

The calculated parameters are based on following areas:<br />

aperture area of 1.924 m 2 : absorber area of 1.840 m 2 :<br />

η 0a = 0.759 η 0A = 0.794<br />

a 1a = 3.480 W/m 2 K a 1A = 3.639 W/m 2 K<br />

a 2a = 0.0161 W/m 2 K 2 a 2A = 0.0168 W/m 2 K 2<br />

<strong>KTB</strong> <strong>Nr</strong>. <strong>2006</strong>-<strong>35</strong>-k-j-<strong>en</strong> : <strong>Collec<strong>to</strong>r</strong> <strong>test</strong> <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong><br />

IMMERGAS S.p.A. , Series Collet<strong>to</strong>re Solare Piano CP4M and Collet<strong>to</strong>re Solare Piano CP2M<br />

04.07.2007, Fraunhofer-ISE, Heid<strong>en</strong>hofstraße 2, D-79110 Freiburg<br />

Page 32 of 37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!