KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

18 Mechanical load <strong>test</strong><br />

18.1 Positive pressure <strong>test</strong> of the collec<strong>to</strong>r cover<br />

The positive pressure (<strong>according</strong> <strong>to</strong> a positive pressure load caused by<br />

snow or wind) was increased in steps of 250 Pa up <strong>to</strong> the maximum<br />

pressure load.<br />

Method used <strong>to</strong> apply pressure:<br />

Maximum pressure load:<br />

suction cups, pressed<br />

1000 Pa<br />

Result:<br />

During and after the <strong>test</strong> no damage at the cover of the collec<strong>to</strong>r was<br />

observed.<br />

18.2 Negative pressure <strong>test</strong> of fixings betwe<strong>en</strong> the cover and the collec<strong>to</strong>r box<br />

The negative pressure (<strong>according</strong> <strong>to</strong> a negative pressure load caused by<br />

wind) was increased in steps of 250 Pa up <strong>to</strong> the maximum pressure load.<br />

Method used <strong>to</strong> apply pressure:<br />

Maximum pressure load:<br />

suction cups<br />

1000 Pa<br />

Result:<br />

During and after the <strong>test</strong> no damage at the cover or at the cover fixings of<br />

the collec<strong>to</strong>r was observed.<br />

18.3 Negative pressure <strong>test</strong> of mountings<br />

The negative pressure (<strong>according</strong> <strong>to</strong> a negative pressure load caused by<br />

wind) was increased in steps of 250 Pa up <strong>to</strong> the maximum pressure load.<br />

Method used <strong>to</strong> apply pressure:<br />

Maximum pressure load:<br />

suction cups<br />

1000 Pa<br />

Result:<br />

During and after the <strong>test</strong> no damage at the collec<strong>to</strong>r mounting fixtures or<br />

fixing points was observed.<br />

<strong>KTB</strong> <strong>Nr</strong>. <strong>2006</strong>-<strong>35</strong>-k-j-<strong>en</strong> : <strong>Collec<strong>to</strong>r</strong> <strong>test</strong> <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong><br />

IMMERGAS S.p.A. , Series Collet<strong>to</strong>re Solare Piano CP4M and Collet<strong>to</strong>re Solare Piano CP2M<br />

04.07.2007, Fraunhofer-ISE, Heid<strong>en</strong>hofstraße 2, D-79110 Freiburg<br />

Page 23 of 37