Cont<strong>en</strong>ts<br />
1 Summary 5<br />
1.1 Preliminary remark . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />
1.2 <strong>Collec<strong>to</strong>r</strong> effici<strong>en</strong>cy parameters determined . . . . . . . . . . . . . . 5<br />
1.3 Incid<strong>en</strong>ce angle modifier - IAM . . . . . . . . . . . . . . . . . . . . . 5<br />
1.4 Pressure drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />
1.5 Effective thermal capacity of the collec<strong>to</strong>r . . . . . . . . . . . . . . . 6<br />
1.6 Schedule of <strong>test</strong>s and callculations . . . . . . . . . . . . . . . . . . . 6<br />
1.7 Summary statem<strong>en</strong>t . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />
2 Test C<strong>en</strong>ter 7<br />
3 Orderer, Expeller, Manufacturer 7<br />
4 Overview of series Collet<strong>to</strong>re Solare Piano CP 8<br />
5 Description of the <strong>Collec<strong>to</strong>r</strong> 8<br />
5.1 Specific data of the smallest collec<strong>to</strong>r of the series Collet<strong>to</strong>re Solare<br />
Piano CP4M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
5.2 Specific data of the smallest collec<strong>to</strong>r of the series Collet<strong>to</strong>re Solare<br />
Piano CP2M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
5.3 Specific data of the largest collec<strong>to</strong>r of the series Collet<strong>to</strong>re Solare<br />
Piano CP4XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
5.4 Specific data of the largest collec<strong>to</strong>r of the series Collet<strong>to</strong>re Solare<br />
Piano CP2XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
5.5 Absorber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
5.6 Insulation and Casing . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
5.7 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
5.8 Kind of mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
5.9 Picture and cut drawing of the collec<strong>to</strong>r . . . . . . . . . . . . . . . . . 12<br />
6 <strong>Collec<strong>to</strong>r</strong> effici<strong>en</strong>cy parameters 13<br />
6.1 Test method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
6.2 Description of the calculation . . . . . . . . . . . . . . . . . . . . . . 13<br />
6.3 Steady stade effici<strong>en</strong>cy parameters based on the aparture area and<br />
fluid mean temperature . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
6.4 Power output per collec<strong>to</strong>r unit . . . . . . . . . . . . . . . . . . . . . 15<br />
<strong>KTB</strong> <strong>Nr</strong>. <strong>2006</strong>-<strong>35</strong>-k-j-<strong>en</strong> : <strong>Collec<strong>to</strong>r</strong> <strong>test</strong> <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong><br />
IMMERGAS S.p.A. , Series Collet<strong>to</strong>re Solare Piano CP4M and Collet<strong>to</strong>re Solare Piano CP2M<br />
04.07.2007, Fraunhofer-ISE, Heid<strong>en</strong>hofstraße 2, D-79110 Freiburg<br />
Page 2 of 37