6.3 Steady stade effici<strong>en</strong>cy parameters based on the aparture area and fluid mean<br />

temperature<br />

Test method:<br />

outdoor, steady state with tracker<br />

Latitude:<br />

48.0 ◦<br />

Longitude:<br />

7.8 ◦<br />

<strong>Collec<strong>to</strong>r</strong> tilt:<br />

tracked betwe<strong>en</strong> <strong>35</strong> ◦ and 55 ◦<br />

<strong>Collec<strong>to</strong>r</strong> azimuth:<br />

tracked<br />

Mean irradiation : 997 W/m 2<br />

Mean wind speed:<br />

3 m/s<br />

Mean flow rate:<br />

140 kg/h<br />

Kind of fluid:<br />

water<br />

Date of measurem<strong>en</strong>t November <strong>2006</strong><br />

Results:<br />

The calculated parameters are based on following areas. They are valid for<br />

the whole series.<br />

aperture area of 1.924 m 2 : absorber area of 1.840 m 2 :<br />

η 0a = 0.759 η 0A = 0.794<br />

a 1a = 3.480 W/m 2 K a 1A = 3.639 W/m 2 K<br />

a 2a = 0.0161 W/m 2 K 2 a 2A = 0.0168 W/m 2 K 2<br />

The determination for the standard deviation (k=2) was performed<br />

<strong>according</strong> <strong>EN</strong>V 13025 (GUM). Based on this calculation the uncertainty is<br />

less than 2%-points of the effici<strong>en</strong>cy values over the complete measured<br />

temperature range ( η 0a = 0.759 +/- 0.02). Based on our experi<strong>en</strong>ce with<br />

the <strong>test</strong> facilities the uncertainty is much smaller and in a range of +/-<br />

1%-point. The standard deviation of the heat loss parameters resulting<br />

from the regression fit curve through the measurem<strong>en</strong>t points is:<br />

a 1a = 3.480 +/- 0.0772 and a 2a = 0.0161 +/- 0.00095 .<br />

For more detailed data and the calculated effici<strong>en</strong>cy curve please see<br />

annex E.2.<br />

<strong>KTB</strong> <strong>Nr</strong>. <strong>2006</strong>-<strong>35</strong>-k-j-<strong>en</strong> : <strong>Collec<strong>to</strong>r</strong> <strong>test</strong> <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong><br />