KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006
KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006
KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
6.3 Steady stade effici<strong>en</strong>cy parameters based on the aparture area and fluid mean<br />
temperature<br />
Test method:<br />
outdoor, steady state with tracker<br />
Latitude:<br />
48.0 ◦<br />
Longitude:<br />
7.8 ◦<br />
<strong>Collec<strong>to</strong>r</strong> tilt:<br />
tracked betwe<strong>en</strong> <strong>35</strong> ◦ and 55 ◦<br />
<strong>Collec<strong>to</strong>r</strong> azimuth:<br />
tracked<br />
Mean irradiation : 997 W/m 2<br />
Mean wind speed:<br />
3 m/s<br />
Mean flow rate:<br />
140 kg/h<br />
Kind of fluid:<br />
water<br />
Date of measurem<strong>en</strong>t November <strong>2006</strong><br />
Results:<br />
The calculated parameters are based on following areas. They are valid for<br />
the whole series.<br />
aperture area of 1.924 m 2 : absorber area of 1.840 m 2 :<br />
η 0a = 0.759 η 0A = 0.794<br />
a 1a = 3.480 W/m 2 K a 1A = 3.639 W/m 2 K<br />
a 2a = 0.0161 W/m 2 K 2 a 2A = 0.0168 W/m 2 K 2<br />
The determination for the standard deviation (k=2) was performed<br />
<strong>according</strong> <strong>EN</strong>V 13025 (GUM). Based on this calculation the uncertainty is<br />
less than 2%-points of the effici<strong>en</strong>cy values over the complete measured<br />
temperature range ( η 0a = 0.759 +/- 0.02). Based on our experi<strong>en</strong>ce with<br />
the <strong>test</strong> facilities the uncertainty is much smaller and in a range of +/-<br />
1%-point. The standard deviation of the heat loss parameters resulting<br />
from the regression fit curve through the measurem<strong>en</strong>t points is:<br />
a 1a = 3.480 +/- 0.0772 and a 2a = 0.0161 +/- 0.00095 .<br />
For more detailed data and the calculated effici<strong>en</strong>cy curve please see<br />
annex E.2.<br />
<strong>KTB</strong> <strong>Nr</strong>. <strong>2006</strong>-<strong>35</strong>-k-j-<strong>en</strong> : <strong>Collec<strong>to</strong>r</strong> <strong>test</strong> <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong><br />
IMMERGAS S.p.A. , Series Collet<strong>to</strong>re Solare Piano CP4M and Collet<strong>to</strong>re Solare Piano CP2M<br />
04.07.2007, Fraunhofer-ISE, Heid<strong>en</strong>hofstraße 2, D-79110 Freiburg<br />
Page 14 of 37