5.5 Absorber<br />

Material of the absorber sheet:<br />

Thickness of the absorber sheets:<br />

Kind of the selective coating:<br />

Absorptivity coeffici<strong>en</strong>t α:<br />

Emissivity coeffici<strong>en</strong>t ε:<br />

Material of the absorber pipes:<br />

Layout of the absorber pipes:<br />

Outer diameter:<br />

Inner diameter:<br />

Distance betwe<strong>en</strong> the pipes:<br />

Material of the header pipe:<br />

Outer diameter of the header pipe:<br />

Inner diameter of the header pipe:<br />

Aluminium (MS)<br />

0.5 mm (MS)<br />

BlueTec; Eta plus (MS)<br />

Alanod; Mirrotherm (MS)<br />

94.0 % ± 2% (MS)<br />

5 % ± 2% (MS)<br />

Copper (MS)<br />

double harpe (MS)<br />

8 mm (MS)<br />

7 mm (MS)<br />

96 mm (MS)<br />

Copper (MS)<br />

22 mm (MS)<br />

20.4 mm (MS)<br />

5.6 Insulation and Casing<br />

5.7 Limitations<br />

Thickness of the insulation at the back:<br />

Thickness of the insulation at the sides:<br />

Material:<br />

Material of the casing:<br />

Sealing material:<br />

Maximum fluid pressure:<br />

Operating fluid pressure:<br />

Maximum service temperature:<br />

Maximum stagnation temperature:<br />

Maximum wind load:<br />

Recomm<strong>en</strong>ded tilt angle:<br />

Flow range recomm<strong>en</strong>dation:<br />

40 (MS)<br />

not exist<strong>en</strong>t<br />

mineral rock wool, black glas fleece<br />

(MS)<br />

Seewater resistant aluminium (MS)<br />

UV restitant silicon adhasive (MS)<br />

1000 kPa (MS)<br />

400 kPa (MS)<br />

no declaration<br />

234.0 ◦ C<br />

no declaration<br />

45 ◦<br />

no declaration (MS)<br />

5.8 Kind of mounting<br />

Flat roof - mounted on the roof:<br />

Tilted roof - mounted on the roof:<br />

Tilted roof - integrated:<br />

Free mounting:<br />

Fassade:<br />

yes (MS)<br />

yes (MS)<br />

no (MS)<br />

yes (MS)<br />

no (MS)<br />

<strong>KTB</strong> <strong>Nr</strong>. <strong>2006</strong>-<strong>35</strong>-k-j-<strong>en</strong> : <strong>Collec<strong>to</strong>r</strong> <strong>test</strong> <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong><br />

IMMERGAS S.p.A. , Series Collet<strong>to</strong>re Solare Piano CP4M and Collet<strong>to</strong>re Solare Piano CP2M<br />