KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006
KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006
KTB Nr. 2006-35-kj-en Collector test according to EN 12975-1,2:2006
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
5.5 Absorber<br />
Material of the absorber sheet:<br />
Thickness of the absorber sheets:<br />
Kind of the selective coating:<br />
Absorptivity coeffici<strong>en</strong>t α:<br />
Emissivity coeffici<strong>en</strong>t ε:<br />
Material of the absorber pipes:<br />
Layout of the absorber pipes:<br />
Outer diameter:<br />
Inner diameter:<br />
Distance betwe<strong>en</strong> the pipes:<br />
Material of the header pipe:<br />
Outer diameter of the header pipe:<br />
Inner diameter of the header pipe:<br />
Aluminium (MS)<br />
0.5 mm (MS)<br />
BlueTec; Eta plus (MS)<br />
Alanod; Mirrotherm (MS)<br />
94.0 % ± 2% (MS)<br />
5 % ± 2% (MS)<br />
Copper (MS)<br />
double harpe (MS)<br />
8 mm (MS)<br />
7 mm (MS)<br />
96 mm (MS)<br />
Copper (MS)<br />
22 mm (MS)<br />
20.4 mm (MS)<br />
5.6 Insulation and Casing<br />
5.7 Limitations<br />
Thickness of the insulation at the back:<br />
Thickness of the insulation at the sides:<br />
Material:<br />
Material of the casing:<br />
Sealing material:<br />
Maximum fluid pressure:<br />
Operating fluid pressure:<br />
Maximum service temperature:<br />
Maximum stagnation temperature:<br />
Maximum wind load:<br />
Recomm<strong>en</strong>ded tilt angle:<br />
Flow range recomm<strong>en</strong>dation:<br />
40 (MS)<br />
not exist<strong>en</strong>t<br />
mineral rock wool, black glas fleece<br />
(MS)<br />
Seewater resistant aluminium (MS)<br />
UV restitant silicon adhasive (MS)<br />
1000 kPa (MS)<br />
400 kPa (MS)<br />
no declaration<br />
234.0 ◦ C<br />
no declaration<br />
45 ◦<br />
no declaration (MS)<br />
5.8 Kind of mounting<br />
Flat roof - mounted on the roof:<br />
Tilted roof - mounted on the roof:<br />
Tilted roof - integrated:<br />
Free mounting:<br />
Fassade:<br />
yes (MS)<br />
yes (MS)<br />
no (MS)<br />
yes (MS)<br />
no (MS)<br />
<strong>KTB</strong> <strong>Nr</strong>. <strong>2006</strong>-<strong>35</strong>-k-j-<strong>en</strong> : <strong>Collec<strong>to</strong>r</strong> <strong>test</strong> <strong>according</strong> <strong>to</strong> <strong>EN</strong> <strong>12975</strong>-1,2:<strong>2006</strong><br />
IMMERGAS S.p.A. , Series Collet<strong>to</strong>re Solare Piano CP4M and Collet<strong>to</strong>re Solare Piano CP2M<br />
04.07.2007, Fraunhofer-ISE, Heid<strong>en</strong>hofstraße 2, D-79110 Freiburg<br />
Page 11 of 37