MC – FRAME SIZE 1 / UP TO 160 A - Schrack
MC – FRAME SIZE 1 / UP TO 160 A - Schrack MC – FRAME SIZE 1 / UP TO 160 A - Schrack
MC – FRAME SIZE 3 / UP TO 630A W SOCKET BASE AND WITHDRAWABLE MODULE FOR MC3 W SCHRACK-INFO • 3- and 4-pole version • For circuit breaker MC3 and load-break switch MC3-N • Not suitable for MC3-N-...DC • For dimensions, see from page 692. MC396711 MC396711 W TECHNICAL DATA • Withdrawable unit complete with control circuit plug unit • In max. at 20 0 C – 605 A • In max. at 40 0 C – 550 A • Mounting position: vertical, 90 0 left • 3 positions: retracted, test, extended. The 3 positions are shown mechanically. • Auxiliary contacts can also be used for remote signalling. Either an NC or NO contact per position. • All connections of auxiliary switches (HIA, HIN, HIV) and undervoltage and shunt releases to the control circuit plug units are already present. • Withdrawable unit and withdrawable module only available in combination with switch. • Add an A to switch part number (e.g.: MC340232A) – Switch will be supplied ready for use with withdrawable feature. • Socket base can be ordered separately and supplied pre-assembled. DESCRIPTION TYPE EAN CODE AVAILABLE ORDER NO. SOCKET BASE Socket base, 3-pole MC3-XAVS 9004840263701 MC396711 Socket base, 4-pole MC3-4-XAVS 9004840387469 MC396712 WITHDRAWABLE MODULE Withdrawable module, 3-pole (delivered with switch, add an A to switch part number) Withdrawable module, 4-pole (delivered with switch, add an A to switch part number) I KNOW WHERE TO FIND IT! THE SCHRACK TECHNIK WEB SHOP WITH NAVIGATOR WWW.SCHRACK.COM Page 640 • Finding product information made easy • Buying products around the clock • Quick access customer service Order no. blue: on stock, usually ready for delivery on the day of order!
MC – FRAME SIZE 3 / UP TO 630A W STANDARD AUXILIARY CONTACT / TRIP-INDICATING AUXILIARY CONTACT TYPE M22 -K10 -K01 .X3 .X1 .X4 .X2 -CK11 .X3 .X1 -CK20 .X3 .X3 .X4 .X4 -CK02 .X1 .X1 W SCHRACK INFO • Switches with the main contacts, used for indicating and interlocking tasks • General trip indication “+” with trip due to voltage release, overload release or short-circuit-release MM216378 .X4 .X2 .X2 .X2 W TECHNICAL DATA Breaking capacity: AC15: 4 A / 230 VAC DC13: 3 A / 24 VDC M22-K: 0.3 A / 220 VDC M22-CK: 0.2 A / 220 VDC W TIPS & TRICKS The trip-indicating auxiliary contact is the same contact as the standard auxiliary contact. It derives its function from its place of installation (left is the alarm contact). Maximum component installation MC3 with auxiliary contact: 3 x standard auxiliary contact (HIN) M22-K.. or M22CK.. + 1 x trip-indicating auxiliary contact (HIA) M22-K.. or M22-CK.. DESCRIPTION TYPE EAN CODE AVAILABLE ORDER NO. 1 NO contact with screw terminals M22-K10 9004840176254 MM216376 1 NC contact with screw terminals M22-K01 9004840176261 MM216378 2 NO contacts with spring terminals M22-CK20 9004840547047 MM107898 2 NC contacts with spring terminals M22-CK02 9004840547054 MM107899 1 NO contact + 1 NC contact with spring terminals M22-CK11 9004840625783 MM107940 W EARLY-MAKE AUXILIARY CONTACT TYPE MC3-XHIV MC299430 D1 3.13 3.13 3.23 D2 3.14 3.14 3.24 W TIPS & TRICKS Maximum component installation with auxiliary contact: 1 x early-make auxiliary contact W SCHRACK INFO • For interlock- and load-shedding circuits as well as for early make of undervoltage release in main switch/Emergency-stop applications. W TECHNICAL DATA • Not in connection with undervoltage release MC3-XU... or shunt release MC3-XA... Early-make during switch on and off (manual switch): approx. 20 ms • Not in connection with remote operator MC-XR Undervoltage or shunt releases • Breaking capacity: AC15: 4 A / 230 VAC DC13: 3 A / 24 VDC, 0.2 A / 220 VDC Page 641 DESCRIPTION TYPE EAN CODE AVAILABLE ORDER NO. Early-make auxiliary switch, 2 NO MC2/3-XHIV 9004840262285 MC299430 Order no. blue: on stock, usually ready for delivery on the day of order!
- Page 1 and 2: MC - FRAME SIZE 1 / UP TO 160 A W C
- Page 3 and 4: MC - FRAME SIZE 1 / UP TO 160 A W C
- Page 5 and 6: MC - FRAME SIZE 1 / UP TO 160 A W L
- Page 7 and 8: MC - FRAME SIZE 1 / UP TO 160 A W S
- Page 9 and 10: MC - FRAME SIZE 1 / UP TO 160 A W U
- Page 11 and 12: MC - FRAME SIZE 1 / UP TO 160 A W R
- Page 13 and 14: MC - FRAME SIZE 1 / UP TO 160 A W E
- Page 15 and 16: MC - FRAME SIZE 1 / UP TO 160 A W T
- Page 17 and 18: MC - FRAME SIZE 1 / UP TO 160 A W C
- Page 19 and 20: MC - FRAME SIZE 2 / UP TO 300A W CI
- Page 21 and 22: MC - FRAME SIZE 2 / UP TO 300A W MO
- Page 23 and 24: MC - FRAME SIZE 2 / UP TO 300A W MO
- Page 25 and 26: MC - FRAME SIZE 2 / UP TO 300A W LO
- Page 27 and 28: MC - FRAME SIZE 2 / UP TO 300A W SO
- Page 29 and 30: MC - FRAME SIZE 2 / UP TO 300A W UN
- Page 31 and 32: MC - FRAME SIZE 2 / UP TO 300A W RE
- Page 33 and 34: MC - FRAME SIZE 2 / UP TO 300A W DO
- Page 35 and 36: MC - FRAME SIZE 2 / UP TO 300A W TU
- Page 37 and 38: MC - FRAME SIZE 2 / UP TO 300A W IP
- Page 39 and 40: MC - FRAME SIZE 2 / UP TO 300 A W T
- Page 41 and 42: MC - FRAME SIZE 3 / UP TO 630A W CI
- Page 43 and 44: MC - FRAME SIZE 3 / UP TO 630A W MO
- Page 45: MC - FRAME SIZE 3 / UP TO 630A W LO
- Page 49 and 50: MC - FRAME SIZE 3 / UP TO 630A W UN
- Page 51 and 52: MC - FRAME SIZE 3 / UP TO 630 A W M
- Page 53 and 54: MC - FRAME SIZE 3 / UP TO 630 A W E
- Page 55 and 56: MC - FRAME SIZE 3 / UP TO 630 A W R
- Page 57 and 58: MC - FRAME SIZE 3 / UP TO 630 A W I
- Page 59 and 60: MC - FRAME SIZE 3 / UP TO 630 A W T
- Page 61 and 62: MC - FRAME SIZE 4 / UP TO 1600 A W
- Page 63 and 64: MC - FRAME SIZE 4 / UP TO 1600 A W
- Page 65 and 66: MC - FRAME SIZE 4 / UP TO 1600 A W
- Page 67 and 68: MC - FRAME SIZE 4 / UP TO 1600 A W
- Page 69 and 70: MC - FRAME SIZE 4 / UP TO 1600 A W
- Page 71 and 72: MC - FRAME SIZE 4 / UP TO 1600 A W
- Page 73 and 74: MC - FRAME SIZE 4 / UP TO 1600 A W
- Page 75 and 76: MC - FRAME SIZE 4 / UP TO 1600A W C
<strong>MC</strong> <strong>–</strong> <strong>FRAME</strong> <strong>SIZE</strong> 3 / <strong>UP</strong> <strong>TO</strong> 630A<br />
W SOCKET BASE AND WITHDRAWABLE MODULE FOR <strong>MC</strong>3<br />
W SCHRACK-INFO<br />
• 3- and 4-pole version<br />
• For circuit breaker <strong>MC</strong>3 and load-break switch <strong>MC</strong>3-N<br />
• Not suitable for <strong>MC</strong>3-N-...DC<br />
• For dimensions, see from page 692.<br />
<strong>MC</strong>396711<br />
<strong>MC</strong>396711<br />
W TECHNICAL DATA<br />
• Withdrawable unit complete with control circuit plug unit<br />
• In max. at 20 0 C <strong>–</strong> 605 A<br />
• In max. at 40 0 C <strong>–</strong> 550 A<br />
• Mounting position: vertical, 90 0 left<br />
• 3 positions: retracted, test, extended. The 3 positions are shown mechanically.<br />
• Auxiliary contacts can also be used for remote signalling. Either an NC or NO contact per position.<br />
• All connections of auxiliary switches (HIA, HIN, HIV) and undervoltage and shunt releases to the control circuit plug<br />
units are already present.<br />
• Withdrawable unit and withdrawable module only available in combination with switch.<br />
• Add an A to switch part number (e.g.: <strong>MC</strong>340232A) <strong>–</strong> Switch will be supplied ready for use with withdrawable feature.<br />
• Socket base can be ordered separately and supplied pre-assembled.<br />
DESCRIPTION TYPE EAN CODE AVAILABLE ORDER NO.<br />
SOCKET BASE<br />
Socket base, 3-pole <strong>MC</strong>3-XAVS 9004840263701 <strong>MC</strong>396711<br />
Socket base, 4-pole <strong>MC</strong>3-4-XAVS 9004840387469 <strong>MC</strong>396712<br />
WITHDRAWABLE MODULE<br />
Withdrawable module, 3-pole (delivered with switch, add an A to switch part number)<br />
Withdrawable module, 4-pole (delivered with switch, add an A to switch part number)<br />
I KNOW WHERE <strong>TO</strong> FIND IT!<br />
THE SCHRACK TECHNIK WEB SHOP WITH NAVIGA<strong>TO</strong>R<br />
WWW.SCHRACK.COM<br />
Page<br />
640<br />
• Finding product information made easy<br />
• Buying products around the clock<br />
• Quick access customer service<br />
Order no. blue: on stock, usually ready for delivery on the day of order!