Chapter 8<br />
Fiber testing (LWL) FiberTEK FDX<br />
3. Use soft key to open menu to designate and save the test portion.<br />
4. Use Up/Down Arrow Keys to navigate between the boxes, and use<br />
Alphanumeric keys to designate the test portion from/to.<br />
5. Press Enter to save the entries. Use Escape to exit menu without making<br />
changes.<br />
8.10.2. Power Meter Mode<br />
Use the power meter (PM) mode to measure light power and loss, if according preferences<br />
are applied The test results can be saved and edited in IDEAL DataCENTER as "Power Meter".<br />
1. Use Arrow Keys to navigate to menu Power Meter Mode and press Enter.<br />
Illustration 8.10.2. Continuous Run<br />
2. Use soft key Run to start continuous run of measurement until it is finished by<br />
pressing soft key Stop.<br />
3. Use soft key to open menu to designate and save the test portion.<br />
4. Use Up/Down Arrow Keys to navigate between the boxes, and use<br />
Alphanumeric keys to designate the test portion from/to.<br />
5. Press Enter to save the entries. Use Escape to exit menu without making<br />
changes.<br />
8.10.3. Set Reference Value<br />
Use soft key Set Ref. Value to define a value that can be used as reference for all<br />
subsequent measurements.<br />
Use soft key Toggle dBm to switch the unit between dBm (decibel-miliwatt) and mW<br />
(miliwatt).<br />
Use soft key Toggle Wavelength to open the menu to select the wavelength.<br />
8.10.4. Light Source Mode<br />
The FiberTEK FDX can be used as a source for other meters or devices. Wavelength is<br />
adjustable and the source can be modulated for use with fiber identifiers.<br />
81