Chapter 5 Autotest 11. Use Alphanumeric Keys to enter a Cable Name for the Cable From/Cable To of test portion. 12. Use Alphanumeric Keys to reset the Current Value of the test meter, or enter an arbitrary value. 13. Make corrections to entries by using the soft keys (delete at cursor position), (delete characters to the left of cursor), / (insert alphanumeric characters at cursor position / overwrite highlighted entry). 14. Press Enter to save the information entered. Escape allows you to exit the menu without making changes. 5.3.2. Default Cable ID Simple cable ID was not selected in Autotest Pref. 1. Use Arrow keys to navigate in "Cable ID" view to option Set… and press Enter. Simple Cable ID (1 cable name) 2. Use Alphanumeric Keys to enter a Cable Name for the test portion. 3. Use Alphanumeric Keys to reset the Current Value of the test meter, or enter an arbitrary value. 4. Use Alphanumeric Keys to enter an arbitrary value for Start and End. Meter is reset after reaching final value. 5. Make corrections to entries by using the soft keys (delete at cursor position), (delete characters to the left of cursor), / (insert alphanumeric characters at cursor position / overwrite highlighted entry). 6. Use symbol to lock a position into entered value. Use symbol to enable Auto Increment of a character. Illustration 1 5.3.2. Single Cable ID 7. Press Enter to save the information entered. Escape allows you to exit the menu without making changes. Double Cable ID (2 cable names, start/end) 1. Use Alphanumeric Keys to enter a Cable Name for the Cable From/Cable To of test portion. 2. Use Alphanumeric Keys to reset the Current Value of the test meter, or enter an arbitrary value. 35
Chapter 5 Autotest 3. Use Alphanumeric Keys to enter an arbitrary value for Start and End. Meter is reset after reaching final value. 4. Make corrections to entries by using the soft keys (delete at cursor position), (delete characters to the left of cursor), / (insert alphanumeric characters at cursor position / overwrite highlighted entry). 5. Use symbol to lock a position into entered value. Use symbol to enable Auto Increment of a character. Illustration 2 5.3.2. Double Cable ID 6. Use soft keys and to switch between the views Cable From and Cable To. 7. Use Alphanumeric Keys to enter a Cable Name for the Cable From/Cable To of test portion. 8. Use Alphanumeric Keys to reset the Current Value of the test meter, or enter an arbitrary value. 9. Use Alphanumeric Keys to enter an arbitrary value for Start and End. Meter is reset after reaching final value. 10. Make corrections to entries by using the soft keys (delete at cursor position), (delete characters to the left of cursor), / (insert alphanumeric characters at cursor position / overwrite highlighted entry). 11. Use symbol to lock a position into entered value. Use symbol to enable Auto Increment of a character. 12. Press Enter to save the information entered. Escape allows you to exit the menu without making changes. 36
- Page 1 and 2: LanTEK ® II Series Manual 0
- Page 3 and 4: Standard Warranty Policy of IDEAL I
- Page 5 and 6: Table of contents CHAPTER 1 Your La
- Page 7 and 8: Table of contents 6.11.1. Insertion
- Page 9 and 10: Table of contents 13.1. Technical S
- Page 11 and 12: Chapter 1 Your LanTEK ® II Cable C
- Page 13 and 14: CHAPTER 2 Product Description 2.1.
- Page 15 and 16: Chapter 2 Product Description 2.1.2
- Page 17 and 18: Chapter 2 Product Description 2.2.
- Page 19 and 20: 2.3. Power Management Chapter 2 Pro
- Page 21 and 22: CHAPTER 3 Basics of the Cable Test
- Page 23 and 24: Chapter 4 Preferences 1. Use Arrow
- Page 25 and 26: Chapter 4 Preferences 1. Use Arrow
- Page 27 and 28: Chapter 4 Preferences 6. Use soft k
- Page 29 and 30: CHAPTER 5 Autotest Using Autotest,
- Page 31 and 32: Chapter 5 Autotest Autotest Pref Th
- Page 33 and 34: Chapter 5 Autotest 2. Use Arrow Key
- Page 35: Chapter 5 Autotest 5.3.1. Simple Ca
- Page 39 and 40: Chapter 5 Autotest 5.4.1. Cable Nam
- Page 41 and 42: Chapter 5 Autotest AAA A / AAA A -
- Page 43 and 44: Chapter 5 Autotest Illustration 2 5
- Page 45 and 46: Chapter 5 Autotest 20. Make correct
- Page 47 and 48: Chapter 5 Autotest 5.6. DualMODE Fu
- Page 49 and 50: Chapter 5 Autotest Illustration 2 5
- Page 51 and 52: Chapter 5 Autotest 5.9. Calibration
- Page 53 and 54: Chapter 5 Autotest 5.9.2. Coaxial C
- Page 55 and 56: Chapter 5 Autotest 3. Use soft key
- Page 57 and 58: Chapter 5 Autotest Illustration 4 5
- Page 59 and 60: CHAPTER 6 Structured Cabling Testin
- Page 61 and 62: Chapter 6 Structured cabling testin
- Page 63 and 64: Chapter 6 Structured cabling testin
- Page 65 and 66: 6.11. Insertion Loss Test (Attenuat
- Page 67 and 68: Chapter 6 Structured cabling testin
- Page 69 and 70: Chapter 6 Structured cabling testin
- Page 71 and 72: Chapter 6 Structured cabling testin
- Page 73 and 74: CHAPTER 8 Fiber Testing with FiberT
- Page 75 and 76: Chapter 8 Fiber testing (LWL) Fiber
- Page 77 and 78: Chapter 8 Fiber testing (LWL) Fiber
- Page 79 and 80: Chapter 8 Fiber testing (LWL) Fiber
- Page 81 and 82: Chapter 8 Fiber testing (LWL) Fiber
- Page 83 and 84: Chapter 8 Fiber testing (LWL) Fiber
- Page 85 and 86: Chapter 8 Fiber testing (LWL) Fiber
Chapter 5<br />
Autotest<br />
3. Use Alphanumeric Keys to enter an arbitrary value for Start and End. Meter is<br />
reset after reaching final value.<br />
4. Make corrections to entries by using the soft keys (delete at cursor<br />
position), (delete characters to the left of cursor), /<br />
(insert alphanumeric characters at cursor position / overwrite highlighted entry).<br />
5. Use symbol to lock a position into entered value. Use symbol to enable<br />
Auto <strong>Inc</strong>rement of a character.<br />
Illustration 2 5.3.2. Double Cable ID<br />
6. Use soft keys and to switch between the views Cable From and<br />
Cable To.<br />
7. Use Alphanumeric Keys to enter a Cable Name for the Cable From/Cable To of<br />
test portion.<br />
8. Use Alphanumeric Keys to reset the Current Value of the test meter, or enter an<br />
arbitrary value.<br />
9. Use Alphanumeric Keys to enter an arbitrary value for Start and End. Meter is<br />
reset after reaching final value.<br />
10. Make corrections to entries by using the soft keys (delete at cursor<br />
position), (delete characters to the left of cursor), /<br />
(insert alphanumeric characters at cursor position / overwrite highlighted entry).<br />
11. Use symbol to lock a position into entered value. Use symbol to enable<br />
Auto <strong>Inc</strong>rement of a character.<br />
12. Press Enter to save the information entered. Escape allows you to exit the menu<br />
without making changes.<br />
36