Test & Measurement Clamp-Pro Clamp Meters 600 Amp (740 Series) • Measures up to 600AAC • Non-contact voltage indicator (70V-600VAC) • Continuity • Tapered jaws with hook tip • Auto/manual ranging • Data hold • Auto power off • Low battery indicator • 2-year warranty 61-744 Compact jaw for use in tight locations. Description Cat. No. 600A Clamp Meter w/TRMS 61-746 600A Clamp Meter 61-744 Includes: Carrying Case and Test Leads. Specifications Range & Resolution N12966 Accuracy AC Current 40.00/400.0/600A 1.7% AC Voltage 400.0/600 V 1.2% DC Voltage 400.0/600 V 0.5% Resistance 400.0/4.000k/ 40.00k 400.0k/4.000M/40.00M Ω 1.0% 600V Clamp Meters 4-in-1 Test Tools (700 Series) • 200AAC current capability • Non-contact voltage (40-600VAC) • Vibration mode to verify AC voltage • Harmonics indicator • Capacitance • Max hold • Continuity • Low battery indication • Integral lead storage • Audible dangerous voltage warning on all ranges • Auto power off • Ergonomic hourglass shape • Compact clamp head • 2-year warranty Description Cat. No. 4-in-1 Test Tool w/TRMS, Backlight 61-704 4-in-1 Test Tool 61-702 Includes: Carrying Case and Silicone Test Leads. 61-704 Jaw opening is 1.25” (32mm). 1000V N12966 Specifications Range & Resolution Accuracy AC Voltage 2000m/200.0/750 V 1.2% DC Voltage 2000m/200.0/1000 V 0.5% AC Current 200.0 A 3.0% Resistance 200.0/200.0k Ω 1.0% Capacitance 200.0µ F 3.0% Jaw opening is 1.3” (33mm). D-4 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance
Multimeter Selection Guide 310 Series 340 Series 360 480 Series 490 Series 600 610 Series 61-310 61-312 61-340 Multimeter SELECTION GUIDE MEASUREMENT FUNCTIONS AC & DC Voltage • • • • • • • • • • • • AC Current • • • • • • • • • DC Current • • • • • • • • • • • Resistance • • • • • • • • • • • • LV Resistance • • • • Audible Continuity • • • • • • • • • • • Diode Test • • • • • • • • • • Capacitance • • • • • • • • Frequency • • • • • • • • Temperature • • • • • • • Duty Factor • • • • Battery Test • • • Decibels • • Phase Rotation • FEATURES Display Type (Digital or Analog) D D D D D D D D D D A A True RMS • • • • • • Auto/Manual Ranging • • • • • • • • Non-Contact Voltage Detection • • Data Hold / Auto Hold D D D D D D A A D Min/Max • • • • • • Min/Max/Avg • • • • • • Peak Min/Max • • • • Relative Mode • • High Speed Analog Bar Graph • • • • • • Auto Power Off • • • • • • • • Backlight • • • • • • • Low Battery Indication • • • • • • • • Dual Display • • • Overload Protection on all Ranges • • • • • • • • • • Data Logging • • Data Acquisition • • Memory Storage & Recall • • Optical USB Interface • • ProVision II Software • • Warranty (years) 2 2 2 2 2 2 2 2 2 2 2 2 CERTIFICATIONS UL 61010 Listed • • • • • • • • • • • • CAT Rating II II III III III IV IV IV IV II II II CE • • • • • • • • • • • • 61-342 61-361 61-484 61-486 61-497 61-498 61-605 61-610 61-614 Multimeters 1-800-435-0705 Customer Assistance WWW.IDEALINDUSTRIES.COM D-5
- Page 111 and 112: Standard (50 lb.) Ties Natural, UV
- Page 113 and 114: Screw Mounting Bases - Low Profile
- Page 115 and 116: Thermo-Shrink ® UF Splice Kits •
- Page 117 and 118: Thermo-Shrink ® Heavy-Wall Heat Sh
- Page 119 and 120: Wire Marker Booklets • Convenient
- Page 121 and 122: Standard & Heavy-Duty Toggle Switch
- Page 123 and 124: Double Insulated Plastic Toggle Swi
- Page 125 and 126: Appliance Rocker Switches L • Gre
- Page 127 and 128: Miniature Indicator Lights • Nylo
- Page 129 and 130: Standard Lockout/Tagout Kit Plant F
- Page 131 and 132: Lock Stations • Resilient polycar
- Page 133 and 134: 480/600V Single/Multi- Pole Breaker
- Page 135 and 136: Wall Switch Lockouts • Our patent
- Page 137 and 138: Voltage & Conduit Markers • Ident
- Page 139 and 140: Mfg. Airpax Airpax 1 American Switc
- Page 141 and 142: Mfg. Cutler Hammer LHB 3 Cutler Ham
- Page 143 and 144: Mfg. Breaker Classification Breaker
- Page 145 and 146: Mfg. Breaker Classification Breaker
- Page 147 and 148: Mfg. Breaker Classification Breaker
- Page 149 and 150: How to Select Resurfacer Grade Smal
- Page 151 and 152: C Stripmaster® Wire Strippers Stri
- Page 153 and 154: Stripmaster ® Wire Strippers and K
- Page 155 and 156: Custom Stripmaster ® Lite Wire Str
- Page 157 and 158: Wire Stripper MIL-spec reference ch
- Page 159 and 160: D Test & Measurement Clamp Meters..
- Page 161: TightSight ® Clamp Meters 1000 & 6
- Page 165 and 166: 361 Contractor-Grade Multimeter •
- Page 167 and 168: SureTrace Circuit Tracers • Recei
- Page 169 and 170: Visit idealheatseeker.com for a dem
- Page 171 and 172: AFCI/GFCI Tester • Tests AFCIs ci
- Page 173 and 174: Insulation Testers • Checks new i
- Page 175 and 176: Split-Jaw Smart Meter • Measures
- Page 177 and 178: Digital Light Meter • Measures al
- Page 179 and 180: Thermocouple • Measures up to 150
- Page 181 and 182: E DATACOMM/NETWORKS Testers........
- Page 183 and 184: SignalTEK II • Save money - by us
- Page 185 and 186: LanXPLORER Series With full In-Line
- Page 187 and 188: SecuriTEST PRO CCTV/Security Tester
- Page 189 and 190: Test-Tone-Trace Kit • Kit include
- Page 191 and 192: Compression Connectors RTQ Reg/Tri/
- Page 193 and 194: Compression Connector Instructions
- Page 195 and 196: F-Type Coaxial Connectors F-Series
- Page 197 and 198: Punch Down Tools • Insert and cut
- Page 199 and 200: UTP/STP/Coaxial Cable Strippers •
- Page 201 and 202: Round Cable Slitting & Ringing Tool
- Page 203 and 204: Pro Installer Kit - 33-945 • This
- Page 205 and 206: Technician’s Service Kit - 33-505
- Page 207 and 208: FiberMASTER Fiber Optic Test Kit Me
- Page 209 and 210: DualScribe Double- Ended Fiber Opti
- Page 211 and 212: Item Page Item Page Item Page Item
Multimeter Selection Guide<br />
310 Series 340 Series 360 480 Series 490 Series 600 610 Series<br />
61-310<br />
61-312<br />
61-340<br />
Multimeter SELECTION GUIDE<br />
MEASUREMENT FUNCTIONS<br />
AC & DC Voltage • • • • • • • • • • • •<br />
AC Current • • • • • • • • •<br />
DC Current • • • • • • • • • • •<br />
Resistance • • • • • • • • • • • •<br />
LV Resistance • • • •<br />
Audible Continuity • • • • • • • • • • •<br />
Diode Test • • • • • • • • • •<br />
Capacitance • • • • • • • •<br />
Frequency • • • • • • • •<br />
Temperature • • • • • • •<br />
Duty Factor • • • •<br />
Battery Test • • •<br />
Decibels • •<br />
Phase Rotation<br />
•<br />
FEATURES<br />
Display Type (Digital or Analog) D D D D D D D D D D A A<br />
True RMS • • • • • •<br />
Auto/Manual Ranging • • • • • • • •<br />
Non-Contact Voltage Detection • •<br />
Data Hold / Auto Hold D D D D D D A A D<br />
Min/Max • • • • • •<br />
Min/Max/Avg • • • • • •<br />
Peak Min/Max • • • •<br />
Relative Mode • •<br />
High Speed Analog Bar Graph • • • • • •<br />
Auto Power Off • • • • • • • •<br />
Backlight • • • • • • •<br />
Low Battery Indication • • • • • • • •<br />
Dual Display • • •<br />
Overload Protection on all Ranges • • • • • • • • • •<br />
Data Logging • •<br />
Data Acquisition • •<br />
Memory Storage & Recall • •<br />
Optical USB Interface • •<br />
ProVision II Software • •<br />
Warranty (years) 2 2 2 2 2 2 2 2 2 2 2 2<br />
CERTIFICATIONS<br />
UL 61010 Listed • • • • • • • • • • • •<br />
CAT Rating II II III III III IV IV IV IV II II II<br />
CE • • • • • • • • • • • •<br />
61-342<br />
61-361<br />
61-484<br />
61-486<br />
61-497<br />
61-498<br />
61-605<br />
61-610<br />
61-614<br />
Multimeters<br />
1-800-435-0705 Customer Assistance WWW.IDEALINDUSTRIES.COM<br />
D-5