•<br />

5780 Thornwood Drive<br />

Goleta, California 93117<br />

www.enerpro-inc.com<br />

Number PD744<br />

September 29, 2000<br />

THE MVTB FAMILY OF FIBER-OPTICALLY COUPLED<br />

MEDIUM VOLTAGE THYRISTOR TRIGGER BOARDS<br />

Introduction<br />

The MVTB family of Medium Voltage<br />

Trigger Boards offers engineers a turnkey<br />

solution for thyris<strong>to</strong>r-based systems<br />

requiring enhanced hard dc gate drive with<br />

complete control electronics isolation.<br />

Fiber-optically coupled gate commands allow<br />

unlimited voltage isolation between the<br />

delay determina<strong>to</strong>r logic unit and the trigger<br />

board. The MVTB drives thyris<strong>to</strong>rs fed with<br />

up <strong>to</strong> 2400 Vac (4160 Vac by January 2001)<br />

with respect <strong>to</strong> the trigger board control<br />

circuit power supply. This isolation is<br />

accomplished with high-voltage pulse<br />

transformers and with creepage in<br />

conforming <strong>to</strong> EN 50178 and UL 840.<br />

Key Specifications<br />

• 4 A/µs Initial Gate Current Rate-of-Rise<br />

• 2 A Initial Peak Current<br />

• 0.5 Adc Sustaining Current for 120 deg.<br />

• Pulse Transformer Isolation >5000 Vac<br />

• Gating & Bias-Supply Status Read-Back<br />

Applications<br />

High isolation voltage and fast, high current<br />

gate drive make the MVTB trigger board<br />

especially suitable for high power rectifiers,<br />

inverters and ac controllers using:<br />

• Advanced Design Thyris<strong>to</strong>rs<br />

(<strong>to</strong> 12 kV Blocking Voltage)<br />

• Series-Connected Thyris<strong>to</strong>rs<br />

• Multiple Converters Series Connected<br />

• Parallel-Connected Thyris<strong>to</strong>rs<br />

Specific Applications <strong>Inc</strong>lude:<br />

• Sub-Cycle ac Transfer Switches<br />

• 1200 V <strong>to</strong> 4160 V Mo<strong>to</strong>r Starters<br />

• MV or HV* Rectifiers With Series-<br />

Connected Thyris<strong>to</strong>rs<br />

• Rectifiers for High Energy Physics<br />

• Plasma Arc Rectifiers<br />

• Pulsed <strong>Power</strong> Systems<br />

*A floating trigger board power supply permits<br />

MVTB operation at an arbitrarily high voltage.<br />

The MVTB-6, Six-Channel Trigger Board s<strong>how</strong>n above is ideal for 2.4 kV mo<strong>to</strong>r soft start systems.<br />

Number PD744 - 1 - PD744 - MVTB Family.doc


Background<br />

The MVTB family was developed <strong>to</strong><br />

accommodate three specific requirements:<br />

First, many industrial environments require<br />

the electrical isolation, noise immunity and<br />

enhanced safety provided by fiber optic<br />

signal transmission.<br />

Second, stringent power quality regulations<br />

frequently necessitate control at medium<br />

voltages, such as sub-cycle transfer<br />

switches and mo<strong>to</strong>r soft starters.<br />

Third, large systems such as pulse<br />

amplifiers and power supplies for highenergy<br />

physics often use series or paralleled<br />

devices. These devices often require dc<br />

gating with high open-circuit voltage, high<br />

peak currents and short rise time pulses.<br />

This helps ensure a small spread in the<br />

turn-on times and adequate immunity<br />

against gate inversion.<br />

Circuit Operation<br />

Each channel of a MVTB board is made up<br />

of four sections: 1) fiber optic receiver and<br />

gating logic, 2) driver stage and pulse<br />

forming network, 3) isolation transformer,<br />

and 4) output rectifier and terminating<br />

resis<strong>to</strong>r.<br />

Fiber-optic receiver (FOR) converts the<br />

gate command light signal in<strong>to</strong> the logic<br />

signal *A. The *A signal is characterized by<br />

a square wave pulse train of 256 pulses at a<br />

nominal frequency of approximately 23kHz<br />

and 5.6 ms duration when the mains<br />

frequency is 60 Hz.<br />

This gate command pulse train is standard<br />

output on all of Enerpro’s firing boards.<br />

Firing cards can be specified with optional<br />

fiber-output pulse modules. The modules<br />

are also available as drop-in field-upgrades<br />

for existing Enerpro boards.<br />

Medium Voltage Trigger Board System<br />

(One Channel S<strong>how</strong>n)<br />

"Blue"<br />

Fiber-<br />

Optic<br />

Links<br />

"Gray"<br />

System Controller<br />

Gate<br />

Command<br />

Receiver<br />

R-2522<br />

"BLUE"<br />

Status<br />

Transmitter<br />

T-1522<br />

"GRAY"<br />

*A<br />

Gating<br />

Logic<br />

(Gate Delay Determina<strong>to</strong>r Board)<br />

Status<br />

Logic<br />

+<br />

H<br />

L<br />

39Ω<br />

+30 V<br />

"GATE ON"<br />

"FAULT"<br />

Current<br />

Limiting<br />

Resis<strong>to</strong>r<br />

Gate<br />

Driver<br />

22µ<br />

22µ<br />

+ +<br />

2Ω<br />

Pulse<br />

Forming<br />

Network<br />

22Ω<br />

6000V<br />

Isolation Barrier<br />

2T<br />

Toroidal<br />

Isolation<br />

Transformer<br />

5T<br />

Pulse<br />

Rectifier<br />

200Ω<br />

G<br />

K<br />

A<br />

K<br />

Bias Supply<br />

(Grounded or Floating)<br />

24 Vac / 30 Vdc<br />

10VA per Channel<br />

5A<br />

COM<br />

Vth H<br />

Vth L<br />

IN<br />

Bias<br />

Supply<br />

+ 30 V<br />

+13V<br />

+5 V<br />

"POWER ON"<br />

MVTB Board<br />

E1193 MVTB Block Diagram.McDraw<br />

Block diagram s<strong>how</strong>ing the Medium Voltage Trigger Board system’s. basic functionality.<br />

Number PD744 - 2 - PD744 - MVTB Family.doc


Gate Drive Stage<br />

Logic converts the *A signal in<strong>to</strong> high- and<br />

low-side power MOSFETs. The logic<br />

disables the driver in the absence of gate<br />

command. The half-bridge applies 128<br />

positive and 128 negative pulses <strong>to</strong> the<br />

transformer’s 2-turn primary over a period<br />

of 1/3 of the mains voltage cycle.<br />

The <strong>to</strong>roidal pulse transformer is wound<br />

with corona-resistant, high voltage wire<br />

rated for 7.5kV nominal (20 kV B.I.L.).<br />

Additionally, PCB slotting and ample<br />

creepage distance assure >5000 Vac<br />

isolation. MVTB boards are available with<br />

potted outputs and higher voltage wire for<br />

isolation <strong>to</strong> 20 kV (80 kV B.I.L.).<br />

Output Pulse Characteristics<br />

The bipolar square wave signal derived<br />

from the 5-turn secondary is full-wave<br />

rectified in<strong>to</strong> a direct current pulse. The<br />

amplitude is initially 30 V decaying <strong>to</strong> ≈12 V<br />

as the half-bridge capaci<strong>to</strong>rs discharge. The<br />

primary-side pulse-forming network creates<br />

high-amplitude initial gate current (2.0 A)<br />

and a lower amplitude (0.5 A) sustaining<br />

current.<br />

The fast recovery rectifiers and 200Ωterminating<br />

resis<strong>to</strong>r provide added noise<br />

immunity and gate reversal protection.<br />

Status Readback<br />

The fiber-optic transmitter (FOT) for each<br />

channel outputs a diagnostic light signal. In<br />

normal operation, the output of the<br />

primary-side gate driver is converted <strong>to</strong> a<br />

logic signal that drives the pho<strong>to</strong>diode of<br />

FOT. The result is a light signal that<br />

mimics the gate command. The bias<br />

supply’s window compara<strong>to</strong>r will turn on<br />

the FOT continuously if the nominal +30 V<br />

supply is outside preset thresholds.<br />

On-Board LED Diagnostics <strong>Inc</strong>lude:<br />

• “POWER ON” indicates board power<br />

• “GATE ON” indicates gate activity<br />

• “FAULT” indicates bias out-of-range<br />

Circuit Board<br />

The circuit boards are assembled at the<br />

Enerpro plant in Goleta, California and are<br />

made by a UL listed fabrica<strong>to</strong>r from 0.093-<br />

in. (2.36-mm) thick FR4 fire-resistant<br />

epoxy-fiberglass laminate. All creepage<br />

distances conform <strong>to</strong> UL 508 and VDE<br />

0110. Boards are conformal-coated (MIL-1-<br />

46058 [Type UR]).<br />

The boards are designed for operation from<br />

0°C <strong>to</strong> +65°C. The boards require forced air<br />

cooling (75 CFM across length of board) at<br />

ambient temperatures above 35°C.<br />

Rugged AMP Mate-N-Lok connec<strong>to</strong>rs are<br />

used for cus<strong>to</strong>mer electrical interface and<br />

are keyed <strong>to</strong> simplify maintenance and<br />

ease trouble-shooting.<br />

Open Circuit Voltage (2 x 30° Bursts Mode).<br />

Ordering Information<br />

Please contact Enerpro for assistance or<br />

use the following "How <strong>to</strong> Order"<br />

worksheet <strong>to</strong> determine the correct part<br />

number. Consult Enerpro’s applications<br />

and design-engineering staff for assistance<br />

when specifying thyris<strong>to</strong>r gate drivers for<br />

cus<strong>to</strong>m applications.<br />

Number PD744 - 3 - PD744 - MVTB Family.doc


HOW TO ORDER<br />

Model<br />

Number Medium Voltage Fiber-Optically Coupled Trigger Board<br />

Code Output Configuration<br />

1<br />

2<br />

3<br />

4<br />

6<br />

Single Output<br />

Dual Output<br />

Triple Output<br />

Quad Output<br />

Hex Output<br />

Code Thyris<strong>to</strong>r Gating Configuration<br />

- Independent Command Inputs<br />

S Single Command Input<br />

Code Physical Configuration<br />

- Standard One-Piece Construction<br />

X Separated Output Circuit Construction<br />

Code Mains Voltage ( In kilovolts)<br />

Code Board Supply Voltage<br />

24 24 Vac<br />

30 30 Vdc<br />

MVTB - - - - -<br />

For more information:<br />

Please contact Enerpro, <strong>Inc</strong>. by telephone at (805) 683-2114, 7:00 A.M. <strong>to</strong> 5:00 P.M.<br />

(PST), M-F, or e-mail Enerpro via Frank Peter Wahl at f.wahl@enerpro-inc.com.<br />

## - ### - ##<br />

Version 9/29/00<br />

Number PD744 - 4 - PD744 - MVTB Family.doc