<strong>Mi</strong> <strong>Distribution</strong> <strong>boards</strong> <br />

Assembly<br />

Service<br />

• Step 5: Wiring<br />

Allocation of terminals for direct busbar connection to<br />

cross-section and <strong>Mi</strong>-boxes:<br />

refer to table on pages 162 and 163.<br />

Connection from 100 A to 630 A between busbars and<br />

built-in equipment<br />

DK<br />

KV<br />

Wiring strip<br />

from laminated copper, insulated, supplied length 2000 mm<br />

<strong>Mi</strong> VS 100<br />

<strong>Mi</strong> VS 160<br />

<strong>Mi</strong> VS 250<br />

<strong>Mi</strong> VS 400<br />

<strong>Mi</strong> VS 630<br />

for rated current 100 A<br />

for rated current 160 A<br />

for rated current 250 A<br />

for rated current 400 A<br />

for rated current 630 A<br />

Wiring instructions for equipment are duly<br />

to be observed (e.g. cross-sections of<br />

connectors min. … mm 2 ).<br />

<strong>Mi</strong><br />

Wiring supply terminals<br />

terminal for direct connection of laminated<br />

copper wiring strip (<strong>Mi</strong> VS 250 and<br />

<strong>Mi</strong> VS 400) up to 400 A to switchgear by<br />

means of lat contact M 10.<br />

MC<br />

VA 400<br />

LES<br />

Wiring strip<br />

<strong>Mi</strong> VS 100/160<br />

Wiring strip<br />

<strong>Mi</strong> VS 250/400<br />

Copper conductor<br />

KS 120 Z<br />

Copper conductor<br />

KS 240/12<br />

Copper conductor<br />

KS 240/20<br />

HENPAS<br />

KS 35 F<br />

KS 120 Z<br />

Connection between busbars and built-in equipment<br />

with wiring strip <strong>Mi</strong> VS 100 or <strong>Mi</strong> VS 160<br />

resp. <strong>Mi</strong> VS 250 or <strong>Mi</strong> VS 400 and terminals for<br />

direct busbar connection KS 35 .. resp. KS 120 ..<br />

Direct connection of copper conductors (s) to busbars.<br />

Technics<br />

Connection of wiring strip 160 A, 250 A and 400 A<br />

Connection of wiring strip 160 A, 250 A and 400 A<br />

References/Types<br />

<strong>Mi</strong> VS ... to<br />

VA 400<br />

184<br />

<strong>Mi</strong> VS ... to<br />

VA 400<br />

<strong>Mi</strong> VS ... to<br />

KS 120<br />

<strong>Mi</strong> VS 630<br />

<strong>Mi</strong> VS 630 to<br />

VA 630<br />

<strong>Mi</strong> VS 630 to<br />

KS 240 V