<strong>Mi</strong> <strong>Distribution</strong> <strong>boards</strong> <br />

Accessories<br />

MC<br />

<strong>Mi</strong><br />

KV<br />

DK<br />

Service<br />

<strong>Mi</strong> VS 100 Wiring strip 100 A<br />

for connections of 100 A between busbars<br />

and built-in equipment<br />

wiring instructions for equipment (e.g. wire<br />

range ...mm²) must be observed<br />

cross-section 3 x 9 x 0,8 mm<br />

<strong>Mi</strong> VS 160 Wiring strip 160 A<br />

for connections of 160 A between busbars<br />

and built-in equipment<br />

wiring instructions for equipment (e.g. wire<br />

range ...mm²) must be observed<br />

cross-section 6 x 9 x 0,8 mm<br />

<strong>Mi</strong> VS 250 Wiring strip 250 A<br />

for connections of 250 A between busbars<br />

and built-in equipment<br />

wiring instructions for equipment (e.g. wire<br />

range ...mm²) must be observed<br />

cross-section 6 x 15,5 x 0,8 mm<br />

<strong>Mi</strong> VS 400 Wiring strip 400 A<br />

for connections of 400 A between busbars<br />

and built-in equipment<br />

wiring instructions for equipment (e.g. wire<br />

range ...mm²) must be observed<br />

cross-section 10 x 15,5 x 0,8 mm<br />

<strong>Mi</strong> VS 630 Wiring strip 630 A<br />

for connections of 630 A between busbars<br />

and built-in equipment<br />

wiring instructions for equipment (e.g. wire<br />

range ...mm²) must be observed<br />

cross-section 11 x 20 x 1 mm<br />

LES<br />

HENPAS<br />

Technics<br />

VA 400<br />

VA 630<br />

DA 240<br />

Wiring terminal up to 400 A<br />

terminal for direct connection of laminated copper wiring strip<br />

(<strong>Mi</strong> VS 250 and <strong>Mi</strong> VS 400) up to 400 A<br />

onto switchgear with flat contact M10<br />

tightening torque 8 Nm<br />

Wiring terminal up to 630 A<br />

terminal for direct connection of laminated copper wiring strip<br />

(<strong>Mi</strong> VS 630) up to 630 A<br />

onto switchgear with flat contact M12<br />

tightening torque 22-24 Nm<br />

Terminal for direct connection<br />

up to 400 A<br />

for mounting onto switchgear with flat contact M10<br />

with insulating cover<br />

rated connecting capacity<br />

35-70 mm² s (round), Cu/Alu<br />

50-185 mm² s (sector), Cu/Alu<br />

35-50 mm² sol, Cu/Alu<br />

70-240 mm² sol (sector), Cu/Alu<br />

tightening torque 22 Nm<br />

Prior to connection, aluminium conductors must be prepared according to the relevant<br />

technical recommendations.<br />

References/Types<br />