Circuit-breakers, switch-disconnectors<br />

Rotary handles with door interlock<br />

81<br />

Moeller SK1230-1157GB-INT<br />

Rotary handles on switch with door interlock<br />

Complete with rotary drive and insulating surround<br />

Standard, black/grey<br />

Can be locked in 0<br />

position, with<br />

adequate modification<br />

also in I position. Also<br />

available with door<br />

interlock e.g. for MCC<br />

service distribution<br />

Red-yellow for Emergency-Stop<br />

Lockable in 0 position<br />

on handle. Also<br />

available with door<br />

interlock e.g. for MCC<br />

service distribution<br />

For use with<br />

NZM1(-4), PN1(-4), N1(-4)<br />

NZM2(-4), PN2(-4), N2(-4)<br />

NZM1(-4), PN1(-4), N1(-4)<br />

NZM2(-4), PN2(-4), N2(-4)<br />

Part no.<br />

Article no.<br />

NZM1-XDTV<br />

260131<br />

NZM2-XDTV<br />

260133<br />

NZM1-XDTVR<br />

260142<br />

NZM2-XDTVR<br />

260144<br />

Price<br />

see price<br />

list<br />

Std. pack<br />

Notes<br />

1 off Door interlock<br />

• In the ON position, can be<br />

defeated from the outside using a<br />

1 mm pin<br />

• Not defeated in the locked OFF<br />

and ON positions<br />

• Door can be opened in OFF<br />

• Can only be switched ON when<br />

the door is closed<br />

1 off<br />

Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

Rotary handle on switch with door interlock<br />

for UL/CSA approved NA switches<br />

Divergent to normal IEC handles: door opening only possible after active rotation<br />

beyond the 0 position.<br />

Complete with rotary drive and insulating surround<br />

Standard, black/grey<br />

Can be locked in 0 NZM1, N1<br />

position, with<br />

adequate modification<br />

also in I position. NZM2, N2<br />

Available with door<br />

interlock e.g. for MCC<br />

service distribution.<br />

Red-yellow for Emergency-Stop<br />

Lockable in 0 position<br />

on handle. Available<br />

with door interlock<br />

e.g. for MCC service<br />

distribution.<br />

NZM1, N1<br />

NZM2, N2<br />

NZM1-XDTV-NA<br />

271453<br />

NZM2-XDTV-NA<br />

271454<br />

NZM1-XDTVR-NA<br />

271455<br />

NZM2-XDTVR-NA<br />

271456<br />

1 off Door interlock<br />

• In the ON position, can be<br />

defeated from the outside using a<br />

1 mm pin<br />

• Not defeated in the locked OFF<br />

and ON positions<br />

• Door opening only possible with<br />

active rotation beyond the 0<br />

position.<br />

• Can only be switched ON when<br />

the door is closed<br />

• Cannot be combined with<br />

mechanical interlock<br />

Notes<br />

Circuit-breaker can also be installed in a lying position 90 ° left/right, with the handle still in the same position.