Circuit-breakers, switch-disconnectors<br />
Undervoltage releases, with screw terminal<br />
61<br />
Moeller SK1230-1157GB-INT<br />
For use with Rated control voltage Part no.<br />
Article no.<br />
when ordered separately<br />
U s<br />
V<br />
Undervoltage releases<br />
With two separate early-make auxiliary contacts<br />
Coil connection wired to clamp terminal,<br />
auxiliary switch connections wired with 3 m loose connection cables<br />
NZM1(-4), N1(-4) 24 V 50/60 Hz NZM1-XUHIV20KL24AC<br />
D1 3.13 3.23<br />
284388<br />
Price<br />
see price<br />
list<br />
Std. pack<br />
1 off<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
D2<br />
3.14<br />
3.24<br />
110 V – 130 V 50/60 Hz NZM1-XUHIV20KL110-130AC<br />
284389<br />
208 V – 240 V 50/60 Hz NZM1-XUHIV20KL208-240AC<br />
284400<br />
24 V DC NZM1-XUHIV20KL24DC<br />
284387<br />
Coil connection with 3 m loose connection cables,<br />
auxiliary switch connections wired to clamp terminal<br />
D1<br />
3.13<br />
3.23<br />
NZM1(-4), N1(-4) 24 V 50/60 Hz NZM1-XUHIV20LK24AC<br />
284402<br />
1 off<br />
D2<br />
3.14<br />
3.24<br />
110 V – 130 V 50/60 Hz NZM1-XUHIV20LK110-130AC<br />
284403<br />
208 V – 240 V 50/60 Hz NZM1-XUHIV20LK208-240AC<br />
284404<br />
24 V DC NZM1-XUHIV20LK24DC<br />
284401<br />
Coil connection with 3 m loose connection cables,<br />
auxiliary switch connections wired to clamp terminal<br />
NZM2(-4), N2(-4)<br />
D1 3.13 3.23<br />
NZM3(-4), N3(-4)<br />
D2<br />
3.14<br />
3.24<br />
24 V 50/60 Hz NZM2/3-XUHIV20LK24AC<br />
285291<br />
110 V – 130 V 50/60 Hz NZM2/3-XUHIV20LK110-130AC<br />
284407<br />
208 V – 240 V 50/60 Hz NZM2/3-XUHIV20LK208-240AC<br />
284408<br />
24 V DC NZM2/3-XUHIV20LK24DC<br />
284405<br />
1 off<br />
Notes<br />
When the undervoltage release is de-energized, accidental contact with the main switches of the switch during attempts to switch on is safely<br />
prevented.<br />
Early-make of the auxiliary contacts with on and off switching (manual operation): approx. 20 ms.<br />
Cannot be used in conjunction with NZM...-XR... remote operator.<br />
Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.