Technical Data - IC SYSTEMS automatika
Technical Data - IC SYSTEMS automatika
Technical Data - IC SYSTEMS automatika
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
60 Circuit-breakers, switch-disconnectors<br />
Undervoltage releases, with screw terminal<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
For use with Rated control voltage<br />
U s<br />
Part no.<br />
Article no.<br />
when ordered separately<br />
V<br />
Undervoltage releases<br />
With two separate early-make auxiliary contacts<br />
With 3 m connection cable instead of screw termination.<br />
NZM1(-4), N1(-4) 24 V 50/60 Hz NZM1-XUHIV20L24AC<br />
D1 3.13 3.23<br />
259612<br />
48 V 50/60 Hz NZM1-XUHIV20L48AC<br />
D2 3.14 3.24<br />
259616<br />
60 V 50/60 Hz NZM1-XUHIV20L60AC<br />
259618<br />
110 V – 130 V 50/60 Hz NZM1-XUHIV20L110-130AC<br />
259620<br />
208 V – 240 V 50/60 Hz NZM1-XUHIV20L208-240AC<br />
259622<br />
380 V – 440 V 50/60 Hz NZM1-XUHIV20L380-440AC<br />
259624<br />
480 V – 525 V 50/60 Hz NZM1-XUHIV20L480-525AC<br />
259626<br />
12 V DC NZM1-XUHIV20L12DC<br />
259628<br />
24 V DC NZM1-XUHIV20L24DC<br />
259630<br />
48 V DC NZM1-XUHIV20L48DC<br />
259632<br />
60 V DC NZM1-XUHIV20L60DC<br />
259634<br />
110 V – 130 V DC NZM1-XUHIV20L110-130DC<br />
259636<br />
220 V – 250 V DC NZM1-XUHIV20L220-250DC<br />
259638<br />
Contacts 3.23 and 3.24 with separate 3 m connection cables.<br />
NZM2(-4), N2(-4)<br />
D1 3.13 3.23<br />
NZM3(-4), N3(-4)<br />
D2<br />
3.14<br />
3.24<br />
24 V 50/60 Hz NZM2/3-XUHIV2024AC<br />
259640<br />
48 V 50/60 Hz NZM2/3-XUHIV2048AC<br />
259643<br />
60 V 50/60 Hz NZM2/3-XUHIV2060AC<br />
259646<br />
110 V – 130 V 50/60 Hz NZM2/3-XUHIV20110-130AC<br />
259648<br />
208 V – 240 V 50/60 Hz NZM2/3-XUHIV20208-240AC<br />
259651<br />
380 V – 440 V 50/60 Hz NZM2/3-XUHIV20380-440AC<br />
259653<br />
480 V – 525 V 50/60 Hz NZM2/3-XUHIV20480-525AC<br />
259655<br />
12 V DC NZM2/3-XUHIV2012DC<br />
259657<br />
24 V DC NZM2/3-XUHIV2024DC<br />
259659<br />
48 V DC NZM2/3-XUHIV2048DC<br />
259661<br />
60 V DC NZM2/3-XUHIV2060DC<br />
259663<br />
110 V – 130 V DC NZM2/3-XUHIV20110-130DC<br />
259665<br />
220 V – 250 V DC NZM2/3-XUHIV20220-250DC<br />
259667<br />
Moeller SK1230-1157GB-INT<br />
Price<br />
see price<br />
list<br />
Std. pack<br />
1 off<br />
1 off<br />
Notes<br />
When the undervoltage release is de-energized, accidental contact with the main switches of the switch during attempts to switch on is safely<br />
prevented.<br />
Early-make of the auxiliary contacts with on and off switching (manual operation): approx. 20 ms.<br />
Cannot be used in conjunction with NZM...-XR... remote operator.<br />
Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.