34<br />
Circuit-breakers for North America<br />
Magnetic 3 pole short-circuit releases<br />
Circuit-breakers for North America<br />
Magnetic 3 pole short-circuit releases<br />
35<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
Rated current = rated<br />
uninterrupted current<br />
I n = I u<br />
A<br />
Setting range<br />
Short-circuit releases<br />
I i<br />
A<br />
I<br />
Basic switching capacity<br />
480 V<br />
600 V<br />
Part no.<br />
Article no.<br />
Short-circuit protection<br />
Motor protection in conjunction with contactor and overload relay<br />
• With short-circuit release<br />
• Without overload release<br />
3 pole<br />
Terminal screws standard<br />
terminals as accessories<br />
1.6 12.8 – 22.4 NZMB2-S1,6-CNA<br />
269472<br />
2.4 19.2 – 33.6 NZMB2-S2,4-CNA<br />
269473<br />
5 32 – 56 NZMB2-S5-CNA<br />
103034<br />
8 48 – 84 NZMB2-S8-CNA<br />
103035<br />
12 80 – 140 NZMB2-S12-CNA<br />
103036<br />
18 128 – 224 NZMB2-S18-CNA<br />
103037<br />
26 200 – 350 NZMB2-S26-CNA<br />
103038<br />
33 256 – 448 NZMB2-S33-CNA<br />
103039<br />
40 320 – 560 NZMB2-S40-CNA<br />
269243<br />
50 400 – 700 NZMB2-S50-CNA<br />
269244<br />
63 504 – 882 NZMB2-S63-CNA<br />
269245<br />
80 640 – 1120 NZMB2-S80-CNA<br />
269246<br />
100 800 – 1400 NZMB2-S100-CNA<br />
269247<br />
125 1000 – 1750 NZMB2-S125-CNA<br />
269248<br />
160 1280 – 2240 NZMB2-S160-CNA<br />
269249<br />
200 1600 – 2500 NZMB2-S200-CNA<br />
269250<br />
250 2000 – 2500 NZMB2-S250-CNA<br />
102478<br />
Price<br />
see price<br />
list<br />
Moeller SK1230-1157GB-INT<br />
Normal switching capacity<br />
480 V<br />
600 V<br />
Part no.<br />
Article no.<br />
NZMN2-S1,6-CNA<br />
269478<br />
NZMN2-S2,4-CNA<br />
269479<br />
NZMN2-S5-CNA<br />
103040<br />
NZMN2-S8-CNA<br />
103041<br />
NZMN2-S12-CNA<br />
103042<br />
NZMN2-S18-CNA<br />
103043<br />
NZMN2-S26-CNA<br />
103044<br />
NZMN2-S33-CNA<br />
103045<br />
NZMN2-S40-CNA<br />
269255<br />
NZMN2-S50-CNA<br />
269256<br />
NZMN2-S63-CNA<br />
269257<br />
NZMN2-S80-CNA<br />
269258<br />
NZMN2-S100-CNA<br />
269259<br />
NZMN2-S125-CNA<br />
269260<br />
NZMN2-S160-CNA<br />
269261<br />
NZMN2-S200-CNA<br />
269262<br />
NZMN2-S250-CNA<br />
102479<br />
Price<br />
see price<br />
list<br />
Moeller SK1230-1157GB-INT<br />
High switching capacity<br />
480 V<br />
600 V<br />
Part no.<br />
Article no.<br />
NZMH2-S1,6-CNA<br />
269482<br />
NZMH2-S2,4-CNA<br />
269483<br />
NZMH2-S5-CNA<br />
103046<br />
NZMH2-S8-CNA<br />
103047<br />
NZMH2-S12-CNA<br />
103048<br />
NZMH2-S18-CNA<br />
103049<br />
NZMH2-S26-CNA<br />
103050<br />
NZMH2-S33-CNA<br />
103051<br />
NZMH2-S40-CNA<br />
269267<br />
NZMH2-S50-CNA<br />
269268<br />
NZMH2-S63-CNA<br />
269269<br />
NZMH2-S80-CNA<br />
269270<br />
NZMH2-S100-CNA<br />
269271<br />
NZMH2-S125-CNA<br />
269272<br />
NZMH2-S160-CNA<br />
269273<br />
NZMH2-S200-CNA<br />
269274<br />
NZMH2-S250-CNA<br />
102490<br />
Price<br />
see price<br />
list<br />
Limiter switching capacity<br />
480 V<br />
600 V<br />
Part no.<br />
Article no.<br />
NZML2-S1,6-CNA<br />
102491<br />
NZML2-S2,4-CNA<br />
102492<br />
NZML2-S5-CNA<br />
103052<br />
NZML2-S8-CNA<br />
103053<br />
NZML2-S12-CNA<br />
103054<br />
NZML2-S18-CNA<br />
103055<br />
NZML2-S26-CNA<br />
103056<br />
NZML2-S33-CNA<br />
103057<br />
NZML2-S40-CNA<br />
102499<br />
NZML2-S50-CNA<br />
102500<br />
NZML2-S63-CNA<br />
102501<br />
NZML2-S80-CNA<br />
102502<br />
NZML2-S100-CNA<br />
102503<br />
NZML2-S125-CNA<br />
102504<br />
NZML2-S160-CNA<br />
102505<br />
NZML2-S200-CNA<br />
102506<br />
NZML2-S250-CNA<br />
102507<br />
Price<br />
see price<br />
list<br />
Std. pack<br />
Notes<br />
1 off Switches conform to UL/CSA as well as the IEC regulations.<br />
40 IEC switching performance values from 40 A are contained on the<br />
rating plate.<br />
UL 489, CSA-C22.2-5.1, IEC/EN 60947-4-1<br />
• NZM...2-S250-CNA: IEC/EN 60947-2<br />
Adjustable short-circuit release I i<br />
• 8 – 14 x I n (ex-factory 12 x I n )<br />
– NZM...2-S5 – 33-CNA: approx. 6 – 10 x I n (ex-factory 10 x I n )<br />
– NZM...2-S250-CNA: 8 – 10 x I n (ex-factory 10 x I n )<br />
Without overload release I r<br />
CNA: The device has components approved to UL, the conditions of<br />
approval must be observed during use.<br />
i.e. the device must be combined with a suitable contactor and overload<br />
relay.<br />
A switching capacity is stated for the complete motor-starter<br />
combination.<br />
The device is approved as a CSA approved single device.<br />
Circuit-breakers, switch-disconnectors<br />
up to 1600 A<br />
Notes Notes for terminals a 99