<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

LES<br />

Technical data<br />

MC<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

<strong>DK</strong> <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

1.5 up to 240 mm², IP 54-65<br />

Solid, modern and user friendly design,<br />

based on 75 years of experience<br />

Halogen-free<br />

Stainless steel quick fastening screws<br />

Accessories included in the box<br />

Boxes for extra applications, refer to pages 12-13<br />

HENPAS<br />

11<br />

References/Types


Service<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Contents<br />

Assortment of Cable <strong>junction</strong> <strong>boxes</strong> pages 11 - 88<br />

<strong>DK</strong><br />

from 1.5 up to 240 mm 2<br />

IP 65/IP 55<br />

<strong>cable</strong> entry via metric knockouts<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors pages 15 - 18<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals pages 19 - 20<br />

from 1.5 up to 50 mm 2<br />

IP 65/IP 55<br />

box walls without <strong>cable</strong> entries, can be drilled individually<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals pages 22 - 23<br />

KV<br />

from 1.5 up to 50 mm 2<br />

IP 55<br />

<strong>cable</strong> entry via metric knockouts<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals pages 25 - 26<br />

Technical data HENPAS<br />

LES<br />

MC<br />

Mi<br />

from 1.5 bis 35 mm 2<br />

IP 65<br />

<strong>cable</strong> entry via metric knockouts for <strong>cable</strong> or conduit entries<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals page 28<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals, box walls without <strong>cable</strong> entry page 29<br />

up to 2.5 mm 2<br />

IP 55<br />

<strong>cable</strong> entry via elastic membranes and integrated M20 thread<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors page 32<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals page 32<br />

from 1.5 up to 4 mm 2<br />

IP 54<br />

<strong>cable</strong> entry via <strong>cable</strong>, <strong>cable</strong> trunking and conduits<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors; accessories page 34<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals; accessories page 35<br />

from 1.5 up to 6 mm 2<br />

IP 55<br />

<strong>cable</strong> entry via elastic membranes<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors, grey RAL 7035 page 37<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals, grey RAL 7035 page 37<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors, white RAL 9016 page 38<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals, white RAL 9016 page 38<br />

from 1.5 up to 240 mm 2<br />

IP 65/55<br />

<strong>cable</strong> entry via metric knockouts<br />

with terminals for aluminium- (Alu) and copper (Cu) conductors<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals pages 40 - 42<br />

References/Types<br />

12


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Contents<br />

for outdoor installation<br />

from 1.5 up to 50 mm 2<br />

IP 65<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors, grey RAL 7032 pages 44 - 45<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals, grey RAL 7032 pages 46 - 47<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors, black RAL 9011 pages 48 - 49<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals, black RAL 9011 pages 50 - 51<br />

for outdoor installation<br />

from 1.5 up to 50 mm 2<br />

IP 65<br />

box walls without <strong>cable</strong> entries, can be drilled individually<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals, grey RAL 7032 pages 53 - 54<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals; black RAL 9011 page 55<br />

Cable <strong>junction</strong> <strong>boxes</strong> without terminals with UL/CSA approval page 57<br />

Service<br />

<strong>DK</strong><br />

KV<br />

tested for functional integrity in the event of fire<br />

from 0.5 up to 10 mm 2<br />

IP 65<br />

<strong>cable</strong> entry via mounted grommets<br />

Cable <strong>junction</strong> <strong>boxes</strong> with functional integrity pages 59 - 60<br />

for hazardous areas to be used in zone 2 and zone 22<br />

from 1.5 up to 25 mm 2<br />

IP 65<br />

<strong>cable</strong> entry via metric knockouts<br />

for special applications<br />

from 1.5 up to 25 mm 2<br />

IP 55/IP 54<br />

<strong>cable</strong> entry via metric knockouts<br />

new<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors, accessories pages 62 - 63<br />

Mi<br />

MC<br />

Cable <strong>junction</strong> <strong>boxes</strong> for security lighting circuits with red lid page 65<br />

for equipotential bonding conductors page 66<br />

with main branch terminals<br />

from 25 up to 35 mm 2<br />

IP 55<br />

<strong>cable</strong>/conduit entry via metric knock outs<br />

LES<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminals for copper conductors 25 mm 2 and 35 mm 2 page 68<br />

<strong>boxes</strong> with terminal blocks for aluminium- (Alu) and copper conductors (Cu)<br />

from 2.5 up to 4 mm 2<br />

IP 65/IP 55<br />

<strong>cable</strong>/conduit entry via metric knock outs<br />

Cable <strong>junction</strong> <strong>boxes</strong> with terminal blocks 2.5 mm 2 up to 4 mm 2 pages 70 - 71<br />

HENPAS<br />

Accessories pages 73 - 76<br />

Technical details pages 78 - 88<br />

Technical data<br />

Additional information on our website: www.hensel-electric.de<br />

13<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

LES<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

MC<br />

Variable terminal mounting<br />

positions (5 positions) and<br />

new terminal technology,<br />

vibration tested.<br />

Included accessories<br />

as listed: grommets<br />

ESM = IP 55<br />

HENPAS<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Hensel <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> can<br />

in general also be used in poor<br />

environmental conditions by using<br />

IP 65 <strong>cable</strong> glands AKM/ASM.<br />

Technical data<br />

Labelling system<br />

for circuit description<br />

References/Types<br />

14


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

with terminals<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 55 (ESM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

Service<br />

D 9025<br />

1.5-2.5 mm², Cu, 3~ <br />

<br />

<br />

<br />

<br />

4 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol,<br />

included <strong>cable</strong> entry 4 ESM 20<br />

(sealing range Ø 6-13 mm)<br />

<br />

<br />

<br />

<br />

<strong>DK</strong><br />

D 9125<br />

1.5-2.5 mm², Cu, 3~ <br />

<br />

<br />

<br />

<br />

4 mm², Cu, 1~ <br />

with external fixing<br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol,<br />

included <strong>cable</strong> entry 4 ESM 20<br />

(sealing range Ø 6-13 mm)<br />

<br />

<br />

<br />

<br />

KV<br />

D 9045<br />

1.5-4 mm², Cu, 3~ <br />

6 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol, 2 x 6 mm² sol,<br />

included <strong>cable</strong> entry 4 ESM 25<br />

(sealing range Ø 9-17 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

K 9065<br />

2.5-6 mm², Cu, 3~ <br />

10 mm², Cu, 1~<br />

5-pole,<br />

4 x 2.5 mm² sol, 4 x 4 mm² sol,<br />

3 x 6 mm² sol, 2 x 10 mm² sol,<br />

included <strong>cable</strong> entry 3 ESM 32<br />

(sealing range Ø 9-23 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

K 9105<br />

4-10 mm², Cu, 3~ <br />

16 mm², Cu, 1~<br />

5-pole,<br />

6 x 2.5 mm² sol, 4 x 4 mm² sol,<br />

4 x 6 mm² sol, 4 x 10 mm² sol, 2 x 16 mm² s<br />

included <strong>cable</strong> entry 3 ESM 32<br />

(sealing range Ø 9-23 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

K 9255<br />

10-25 mm², Cu, 3~ <br />

35 mm², Cu, 1~<br />

5-pole,<br />

6 x 10 mm² sol, 4 x 16 mm² s,<br />

4 x 25 mm² s, 2 x 35 mm² s,<br />

included <strong>cable</strong> entry 3 ESM 40<br />

(sealing range Ø 17-30 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

Technical data<br />

15<br />

References/Types


KV<br />

LES<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

Service<br />

with terminals<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 55 (ESM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<strong>DK</strong><br />

K 9502 10-35 mm², Cu, 3~<br />

5-pole,<br />

4 x 10 mm² sol, 4 x 16 mm² s,<br />

4 x 25 mm² s, 2 x 35 mm² s,<br />

included <strong>cable</strong> entry 3 ESM 40<br />

(sealing range Ø 17-30 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

K 9355 16-35 mm², Cu, 3~<br />

5-pole,<br />

4 x 16 mm² s, 4 x 25 mm² s,<br />

4 x 35 mm² s,<br />

included <strong>cable</strong> entry 3 ESM 40<br />

(sealing range Ø 17-30 mm)<br />

new<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

K 9504 16-50 mm², Cu, 3~<br />

4-pole,<br />

4 x 16 mm² s, 4 x 25 mm² s,<br />

4 x 35 mm² s, 4 x 50 mm² s,<br />

<strong>cable</strong> entry<br />

order AKM/ASM separately (refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

Technical data<br />

K 9505 16-50 mm², Cu, 3~<br />

5-pole,<br />

4 x 16 mm² s, 4 x 25 mm² s,<br />

4 x 35 mm² s, 4 x 50 mm² s,<br />

PE max. 35 mm²<br />

<strong>cable</strong> entry<br />

order AKM/ASM separately (refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

16


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

with terminals<br />

opaque lid with fasteners for tool operation<br />

sealable<br />

Order <strong>cable</strong> glands, flanges and other<br />

accessories separately as required<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material impact-resistant PC polycarbonate<br />

colour grey, RAL 7032<br />

Service<br />

K 7004 16-70 mm², Cu, 3~ <br />

4-pole,<br />

4 x 16-70 mm² s<br />

<strong>cable</strong> entry via flanges,<br />

see accessories<br />

<br />

<strong>DK</strong><br />

K 7005 16-70 mm², Cu, 3~ <br />

5-pole,<br />

4 x 16-70 mm² s<br />

<strong>cable</strong> entry via flanges,<br />

see accessories<br />

<br />

KV<br />

MC<br />

Technical data<br />

Mi<br />

K 1204 16-150 mm², Cu/Alu, 3~ <br />

4-pole,<br />

2 x 16-150 mm² or 4 x 16-70 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flanges, see accessories<br />

Prior to connection, aluminium conductors must<br />

be prepared according to the relevant technical<br />

recommendations.<br />

K 1205 16-150 mm², Cu/Alu, 3~ <br />

5-pole,<br />

2 x 16-150 mm² or 4 x 16-70 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

Prior to connection, aluminium conductors must<br />

be prepared according to the relevant technical<br />

recommendations.<br />

<br />

<br />

LES<br />

HENPAS<br />

17<br />

References/Types


KV<br />

MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

Service<br />

with terminals<br />

opaque lid with fasteners for tool operation<br />

sealable<br />

Order <strong>cable</strong> glands, flanges and other<br />

accessories separately as required<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material impact-resistant PC polycarbonate<br />

colour grey, RAL 7032<br />

<strong>DK</strong><br />

K 2404 25-240 mm², Cu/Alu, 3~ <br />

4-pole,<br />

2 x 25-185/240 mm² or 4 x 25-120 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

<br />

Prior to connection, aluminium conductors must<br />

be prepared according to the relevant technical<br />

recommendations.<br />

Mi<br />

K 2405 25-240 mm², Cu/Alu, 3~ <br />

5-pole,<br />

2 x 25-185/240 mm² or 4 x 25-120 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

<br />

Prior to connection, aluminium conductors must<br />

be prepared according to the relevant technical<br />

recommendations.<br />

References/Types<br />

18


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

without terminals<br />

degree of protection IP 55 (ESM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

Service<br />

D 9020<br />

2.5 mm², 3~ <br />

<br />

<br />

<br />

<br />

4 mm², 1~ <br />

included <strong>cable</strong> entry 4 ESM 20<br />

(sealing range Ø 6-13 mm)<br />

<br />

<br />

<br />

<br />

<strong>DK</strong><br />

D 9120<br />

2.5 mm², 3~ <br />

<br />

<br />

<br />

<br />

4 mm², 1~ <br />

with external fixing<br />

included <strong>cable</strong> entry 4 ESM 20<br />

(sealing range Ø 6-13 mm)<br />

<br />

<br />

<br />

<br />

KV<br />

D 9140<br />

4 mm², 3~ <br />

<br />

<br />

<br />

<br />

6 mm², 1~ <br />

included <strong>cable</strong> entry 4 ESM 20<br />

(sealing range Ø 6-13 mm)<br />

<br />

<br />

<br />

<br />

Mi<br />

D 9040<br />

4 mm², 3~ <br />

6 mm², 1~ <br />

included <strong>cable</strong> entry 4 ESM 25<br />

(sealing range Ø 9-17 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

K 9060<br />

6 mm², 3~ <br />

10 mm², 1~<br />

included <strong>cable</strong> entry 3 ESM 32<br />

(sealing range Ø 9-23 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

K 9100<br />

10 mm², 3~ <br />

16 mm², 1~<br />

included <strong>cable</strong> entry 3 ESM 32<br />

(sealing range Ø 9-23 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

K 9250<br />

25 mm², 3~ <br />

35 mm², 1~<br />

included <strong>cable</strong> entry 3 ESM 40<br />

(sealing range Ø 17-30 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Technical data<br />

19<br />

References/Types


<strong>DK</strong><br />

Mi<br />

MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

Service<br />

without terminals<br />

K 9350 35 mm², 3~<br />

included <strong>cable</strong> entry 3 ESM 40<br />

(sealing range Ø 17-30 mm)<br />

degree of protection IP 55 (ESM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

new<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

K 9500 50 mm², 3~<br />

<strong>cable</strong> entry: order AKM/ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

<br />

<br />

<br />

<br />

20


<strong>DK</strong> <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

box walls without <strong>cable</strong> entry, can be drilled individually<br />

Technical data<br />

HENPAS<br />

LES<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

Cable entries can be drilled<br />

individually.<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

MC<br />

Labelling system<br />

for circuit description.<br />

21<br />

References/Types


<strong>DK</strong><br />

KV<br />

Mi<br />

MC<br />

LES<br />

Technical data<br />

<strong>DK</strong> <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

box walls without <strong>cable</strong> entry, can be drilled individually<br />

Service<br />

without terminals degree of protection IP 65<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

D 8020 <br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 20<br />

<br />

D 8120 <br />

with external fixing<br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 20<br />

<br />

D 8040 <br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 20<br />

<br />

K 8060 <br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 32<br />

<br />

<br />

K 8100 <br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 32<br />

<br />

HENPAS<br />

K 8250 <br />

<br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 40<br />

<br />

References/Types<br />

22


<strong>DK</strong> <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

box walls without <strong>cable</strong> entry, can be drilled individually<br />

without terminals degree of protection IP 65<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

K 8350 <br />

<br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 50<br />

new<br />

Service<br />

KV<br />

Technical data<br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

<strong>DK</strong><br />

K 8500 <br />

<br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 50<br />

<br />

<br />

23<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

MC<br />

Included accessories<br />

as listed:<br />

stepped grommets<br />

STM = IP 55<br />

Degree of protection IP 65<br />

using <strong>cable</strong> glands ASM..<br />

available as an accessory.<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Labelling system<br />

for circuit description.<br />

References/Types<br />

24


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

without terminals<br />

D 6020 2,5 mm², 3~<br />

4 mm², 1~ <br />

<strong>cable</strong> entry 4 STM 20<br />

(sealing range Ø 5-16 mm)<br />

degree of protection IP 55 (STM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Service<br />

KV<br />

Mi<br />

MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong><br />

D 6120 2,5 mm², 3~<br />

<br />

<br />

<br />

<br />

4 mm², 1~ <br />

with external fixing<br />

<strong>cable</strong> entry 4 STM 20<br />

(sealing range Ø 5-16 mm)<br />

<br />

<br />

<br />

<br />

D 6040 4 mm², 3~<br />

6 mm², 1~ <br />

<strong>cable</strong> entry 4 STM 25<br />

(sealing range Ø 5-21 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 6060 6 mm², 3~<br />

10 mm², 1~<br />

<br />

<br />

<br />

<br />

<br />

<strong>cable</strong> entry 3 STM 32<br />

(sealing range Ø 13-26,5 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 6100 10 mm², 3~<br />

16 mm², 1~<br />

<strong>cable</strong> entry 3 STM 32<br />

(sealing range Ø 13-26,5 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 6250 25 mm², 3~<br />

35 mm², 1~<br />

<strong>cable</strong> entry 3 STM 40<br />

(sealing range Ø 13-34 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

25<br />

References/Types


KV<br />

Mi<br />

MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via metric knockouts<br />

Service<br />

<strong>DK</strong><br />

without terminals<br />

K 6500 50 mm², 3~<br />

<strong>cable</strong> entry 3 STM 40<br />

(sealing range Ø 13-34 mm)<br />

degree of protection IP 55 (STM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

26


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> or conduit entry via metric knockouts<br />

HENPAS<br />

LES<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

Application:<br />

Cable <strong>junction</strong> box<br />

using entries for conduits.<br />

Application:<br />

Cable <strong>junction</strong> box<br />

using special <strong>cable</strong> entries.<br />

MC<br />

Application:<br />

Cable <strong>junction</strong> box<br />

using entries for conduits.<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Labelling system<br />

for circuit description.<br />

Technical data<br />

27<br />

References/Types


<strong>DK</strong><br />

KV<br />

Mi<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> or conduit entry via metric knockouts<br />

Service<br />

without terminals<br />

DM 9020<br />

<strong>cable</strong> entry to be ordered separately<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<br />

<br />

<br />

MC<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

DM 9140<br />

<br />

<br />

<br />

<br />

<strong>cable</strong> entry to be ordered separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

DM 9040<br />

<br />

<br />

<br />

<br />

<strong>cable</strong> entry to be ordered separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

KM 9060<br />

<strong>cable</strong> entry to be ordered separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

<br />

<br />

<br />

28


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> or conduit entry via metric knock outs<br />

with terminals<br />

DM 9025 1.5-2.5 mm², Cu, 3~<br />

4 mm², Cu, 1~ <br />

<strong>cable</strong> entry to be ordered separately<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Service<br />

Technical data<br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

DM 9145 1.5-4 mm², Cu, 3~<br />

<br />

<br />

<br />

<br />

6 mm², Cu, 1~ <br />

<strong>cable</strong> entry to be ordered separately<br />

<br />

<br />

<br />

DM 9045 1.5-4 mm², Cu, 3~<br />

6 mm², Cu, 1~ <br />

<strong>cable</strong> entry to be ordered separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KM 9065 2.5-6 mm², Cu, 3~<br />

10 mm², Cu, 1~<br />

<br />

<br />

<br />

<br />

<br />

<strong>cable</strong> entry to be ordered separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

29<br />

References/Types


MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

box walls without <strong>cable</strong> entry, can be drilled individually<br />

Service<br />

<strong>DK</strong><br />

with terminals<br />

K 8105 4-10 mm², Cu, 3~<br />

16 mm², Cu, 1~<br />

5-pole,<br />

6 x 2.5 mm 2 sol, 4 x 4 mm 2 sol,<br />

4 x 6 mm 2 sol, 4 x10 mm 2 sol, 2 x16 mm 2 s<br />

box walls without <strong>cable</strong> entry<br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 32<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<br />

<br />

<br />

KV<br />

K 8255 10-25 mm², Cu, 3~<br />

35 mm², Cu, 1~<br />

<br />

<br />

Mi<br />

5-pole,<br />

4 x 10 mm 2 sol, 4 x 16 mm 2 sol,<br />

4 x 25 mm 2 s, 2 x 35 mm 2 s<br />

box walls without <strong>cable</strong> entry<br />

wall surface can be drilled individually<br />

for <strong>cable</strong> entry max. M 40<br />

<br />

References/Types<br />

30


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via elastic membranes and integrated M 20 thread<br />

Technical data<br />

LES<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

IP 55 with <strong>cable</strong> entry<br />

via elastic membranes,<br />

<strong>cable</strong> entry without <strong>cable</strong> glands.<br />

Captive cover screws<br />

with quick-release lock.<br />

MC<br />

IP 65 with ADM 20 <strong>cable</strong> gland<br />

without locknut. The gland is<br />

secured by an integrated<br />

M 20 thread.<br />

HENPAS<br />

31<br />

References/Types


LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via elastic membranes and integrated M 20 thread<br />

rated insulation voltage 400 V<br />

degree of protection IP 55<br />

Service<br />

degree of protection IP 65 (ADM)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

DN 2000<br />

2.5 mm², Cu, 3~ <br />

<br />

<br />

<br />

<br />

<strong>DK</strong><br />

4 mm², Cu, 1~ <br />

8 membranes, closed,<br />

(sealing range Ø 3-12 mm),<br />

integrated M 20 thread,<br />

without terminal<br />

<br />

<br />

<br />

<br />

<br />

DN 2030<br />

2.5 mm², Cu, 3~ <br />

<br />

<br />

<br />

<br />

KV<br />

4 mm², Cu, 1~ <br />

included <strong>cable</strong> entry 3 ADM 20<br />

(sealing range Ø 6.5-13.5 mm),<br />

8 membranes, closed,<br />

(sealing range Ø 3-12 mm),<br />

integrated M 20 thread,<br />

without terminal<br />

<br />

<br />

<br />

<br />

<br />

DN 2035<br />

2.5 mm², Cu, 3~ <br />

<br />

<br />

<br />

<br />

Mi<br />

4 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1.5 mm 2 sol, 4 x 2.5 mm 2 ,<br />

3 x 4 mm 2 sol,<br />

included <strong>cable</strong> entry 3 ADM 20<br />

(sealing range Ø 6.5-13.5 mm), ,<br />

8 membranes, closed,<br />

(sealing range Ø 3-12 mm),<br />

integrated M 20 thread<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

Cable glands<br />

degree of protection IP 65<br />

colour grey, similar to RAL 7035<br />

material thermoplastic<br />

ADM 20<br />

ISO thread<br />

M 20 x 1.5<br />

sealing range<br />

Ø 6.5-13.5 mm<br />

References/Types<br />

32


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via <strong>cable</strong>, <strong>cable</strong> trunking and conduits<br />

LES<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

Simply cut out <strong>cable</strong> trunking wall<br />

to the required width.<br />

The clean installation solution for<br />

<strong>cable</strong> trunking!<br />

MC<br />

Removable trunking adapters<br />

for connection of <strong>cable</strong> trunkings<br />

to <strong>junction</strong> <strong>boxes</strong>.<br />

The <strong>cable</strong>s can be inserted from the<br />

front!<br />

No threading of <strong>cable</strong>s neccessary!<br />

Supplied accessory<br />

grommets<br />

DPS 02 = IP 54<br />

HENPAS<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Labelling system<br />

for circuit description.<br />

Technical data<br />

33<br />

References/Types


HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via <strong>cable</strong>, <strong>cable</strong> trunking and conduits<br />

Service<br />

with terminals<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 54<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<strong>DK</strong><br />

DP 9025 1.5-2.5 mm², Cu, 3~<br />

4 mm², Cu 1~<br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol<br />

included <strong>cable</strong> entry 4 DPS 02<br />

(sealing range Ø 10-13,5 mm)<br />

<br />

<br />

<br />

DP 9221 1.5-2.5 mm², Cu, 3~<br />

4 mm², Cu 1~<br />

<br />

<br />

KV<br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol<br />

included <strong>cable</strong> entry 7 DPS 02<br />

(sealing range Ø 10-13,5 mm)<br />

<br />

DP 9222 1.5-2.5 mm², Cu, 3~<br />

4 mm², Cu 1~<br />

<br />

<br />

Mi<br />

2 terminals<br />

5-pole,<br />

6 x 1,5 mm² sol, 4 x 2,5 mm² sol, 3 x 4 mm² sol<br />

included <strong>cable</strong> entry 7 DPS 02<br />

(sealing range Ø 10-13,5 mm)<br />

<br />

MC<br />

LES<br />

DPS 02<br />

ERA 20<br />

removable grommet<br />

for retrofitting<br />

degree of protection IP 54<br />

sealing range Ø 10-13,5 mm<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> DP 9020, DP 9220,<br />

DP 9025, DP 9221, DP 9222, DP 9026<br />

removable conduit adapter<br />

degree of protection IP 54<br />

for wiring conduits M 20<br />

EKA 20<br />

removable trunking adapter<br />

degree of protection IP 54<br />

for mini trunking 20 x 20 mm<br />

References/Types<br />

34


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via <strong>cable</strong>, <strong>cable</strong> trunking and conduits<br />

without terminals degree of protection IP 54<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

DP 9020 2.5 mm², 3~<br />

4 mm², 1~<br />

included <strong>cable</strong> entry 4 DPS 02<br />

(sealing range Ø 10-13.5 mm)<br />

<br />

<br />

<br />

Service<br />

Mi<br />

MC<br />

Technical data<br />

HENPAS<br />

LES<br />

KV<br />

<strong>DK</strong><br />

DP 9220 2.5 mm², 3~<br />

4 mm², 1~<br />

<br />

<br />

included <strong>cable</strong> entry 7 DPS 02<br />

(sealing range Ø 10-13.5 mm)<br />

<br />

DPS 02<br />

removable grommet<br />

for retrofitting<br />

degree of protection IP 54<br />

sealing range Ø 10-13.5 mm<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> DP 9020, DP 9220,<br />

DP 9025, DP 9221, DP 9222, DP 9026<br />

ERA 20<br />

removable conduit adapter<br />

degree of protection IP 54<br />

for wiring conduits M 20<br />

EKA 20<br />

removable trunking adapter<br />

degree of protection IP 54<br />

for mini trunking 20 x 20 mm<br />

35<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

LES<br />

HENPAS<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via elastic membranes<br />

MC<br />

No punching tool required - insert<br />

the conductor and it‘s done<br />

Grommet supplied for sealing<br />

membranes in case of<br />

modifications.<br />

Degree of protection IP 55<br />

with box wall with 3 <strong>cable</strong> entries<br />

Technical data<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Labelling system<br />

for circuit description.<br />

References/Types<br />

36


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via elastic membranes<br />

colour grey, RAL 7035<br />

DE 9325<br />

1.5-2.5 mm², Cu, 3~ <br />

4 mm², Cu, 1~<br />

with terminals,<br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol,<br />

<strong>cable</strong> entry 10 elastic membranes, closed<br />

(sealing range Ø 6.5-16 mm)<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 55<br />

material thermoplastic<br />

<br />

<br />

<br />

Service<br />

<strong>DK</strong><br />

DE 9345<br />

1.5-4 mm², Cu, 3~ <br />

6 mm², Cu, 1~<br />

with terminals,<br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol,<br />

2 x 6 mm² sol<br />

<strong>cable</strong> entry 10 elastic membranes, closed<br />

(sealing range Ø 6.5-18 mm)<br />

<br />

<br />

<br />

KV<br />

DE 9320<br />

2.5 mm², 3~ <br />

4 mm², 1~<br />

without terminals,<br />

10 elastic membranes, closed<br />

<strong>cable</strong> entry 10 elastic membranes, closed<br />

(sealing range Ø 6.5-16 mm)<br />

<br />

<br />

<br />

Mi<br />

DE 9340<br />

4 mm², 3~ <br />

6 mm², 1~<br />

without terminals<br />

10 elastic membranes, closed<br />

<strong>cable</strong> entry 10 elastic membranes, closed<br />

(sealing range Ø 6.5-18 mm)<br />

MC<br />

Technical data<br />

HENPAS<br />

LES<br />

<br />

<br />

<br />

37<br />

References/Types


LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

<strong>cable</strong> entry via elastic membranes<br />

Service<br />

<strong>DK</strong><br />

colour white, RAL 9016<br />

DE 9326<br />

1.5-2.5 mm², Cu, 3~ <br />

4 mm², Cu, 1~<br />

with terminals,<br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol,<br />

<strong>cable</strong> entry 10 elastic membranes, closed<br />

(sealing range Ø 6.5-16 mm)<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 55<br />

material thermoplastic<br />

<br />

<br />

<br />

KV<br />

DE 9346<br />

1.5-4 mm², Cu, 3~ <br />

6 mm², Cu, 1~<br />

with terminals,<br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol,<br />

2 x 6 mm² sol<br />

<strong>cable</strong> entry 10 elastic membranes, closed<br />

(sealing range Ø 6.5-18 mm)<br />

<br />

<br />

<br />

Mi<br />

DE 9321<br />

2.5 mm², 3~ <br />

4 mm², 1~<br />

without terminals,<br />

<strong>cable</strong> entry 10 elastic membranes, closed<br />

(sealing range Ø 6.5-16 mm)<br />

<br />

<br />

<br />

MC<br />

DE 9341<br />

4 mm², 3~ <br />

6 mm², 1~<br />

without terminals,<br />

<strong>cable</strong> entry 10 elastic membranes, closed<br />

(sealing range Ø 6.5-18 mm)<br />

<br />

<br />

<br />

References/Types<br />

38


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with terminals for aluminium and copper conductors<br />

Technical data<br />

HENPAS<br />

LES<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

Degree of protection up to IP 65.<br />

In the case of twisted <strong>cable</strong>s, <strong>cable</strong><br />

glands are required in principle to<br />

achieve the degree of protection<br />

IP 54.<br />

Separate clamping units for<br />

aluminium and copper<br />

conductors.<br />

MC<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Labelling system<br />

for circuit description.<br />

39<br />

References/Types


KV<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with terminals for aluminium and copper conductors<br />

<strong>cable</strong> entry via metric knockouts<br />

Service<br />

In the case of twisted <strong>cable</strong>s, <strong>cable</strong> glands are<br />

required in principle to achieve the degree of<br />

protection IP 54.<br />

Prior to connection, aluminium conductors must<br />

be prepared according to the relevant technical<br />

recommendations.<br />

See Technical details for more information about<br />

terminal assignment<br />

degree of protection IP 55 (ESM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<strong>DK</strong><br />

D 9041 1.5-2.5 mm² Cu/Alu, 3~<br />

5-pole,<br />

4 x 1.5 mm², sol/f, 4 x 2.5 mm² sol/f,<br />

rated insulation voltage AC/DC 250 V<br />

current carrying capacity of the terminal 20 A<br />

included <strong>cable</strong> entry 4 ESM 25<br />

(sealing area Ø 9-17 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

K 9061 1.5-4 mm² Cu/Alu, 3~<br />

5-pole,<br />

4 x 1.5 mm², sol/f, 4 x 2.5 mm² sol/f,<br />

4 x 4 mm² sol/f<br />

rated insulation voltage AC/DC 400 V<br />

current carrying capacity of the terminal 20 A<br />

included <strong>cable</strong> entry 3 ESM 32<br />

(sealing area Ø 9-23 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

K 9101 2.5-6 mm² Cu/Alu, 3~<br />

5-pole,<br />

4 x 2.5 mm², sol/f, 4 x 4 mm² sol/f,<br />

4 x 6 mm² sol/f<br />

rated insulation voltage AC/DC 690 V<br />

current carrying capacity of the terminal 41 A<br />

<strong>cable</strong> entry included 3 ESM 32<br />

(sealing area Ø 9-23 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

K 9251 6-16 mm² Cu/Alu, 3~<br />

5-pole,<br />

4 x 6 mm², sol/f, 4 x 10 mm² sol/f,<br />

4 x 16 mm² sol/f<br />

rated insulation voltage AC/DC 400 V<br />

current carrying capacity of the terminal 76 A<br />

<strong>cable</strong> entry included 3 ESM 40<br />

(sealing area Ø 17-30 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

Technical data<br />

K 9501 16-35 mm² Cu/Alu, 3~<br />

5-pole,<br />

4 x 16 mm², sol/f, 4 x 25 mm² sol/f,<br />

4 x 35 mm² sol/f<br />

rated insulation voltage AC/DC 690 V<br />

current carrying capacity of the terminal 125 A<br />

<strong>cable</strong> entry order AKM/ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

40


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with terminals for aluminium and copper conductors<br />

<strong>cable</strong> entry via metric knockouts<br />

sealable<br />

Order <strong>cable</strong> glands, flanges and other accessories<br />

separately as required<br />

Prior to connection, aluminium conductors must<br />

be prepared according to the relevant technical<br />

recommendations.<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material impact-resistant PC polycarbonate<br />

colour grey, RAL 7032<br />

Order threaded <strong>cable</strong> glands, flanges and other<br />

accessories separately as required<br />

Service<br />

K 7042 16-70 mm², Cu/Alu, 3~ <br />

4-pole,<br />

2 x 16-70 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

Technical data<br />

<br />

KV<br />

<strong>DK</strong><br />

K 7052 16-70 mm², Cu/Alu, 3~ <br />

5-pole,<br />

2 x 16-70 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

<br />

Mi<br />

K 1204 16-150 mm², Cu/Alu, 3~ <br />

4-pole,<br />

2 x 16-150 mm² or 4 x 16 - 70 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

<br />

MC<br />

LES<br />

K 1205 16-150 mm², Cu/Alu, 3~ <br />

5-pole,<br />

2 x 16-150 mm² or 4 x 16 - 70 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

<br />

HENPAS<br />

41<br />

References/Types


KV<br />

MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with terminals for aluminium and copper conductors<br />

<strong>cable</strong> entry via metric knockouts<br />

Service<br />

sealable<br />

Order threaded <strong>cable</strong> glands, flanges and other<br />

accessories separately as required<br />

Prior to connection, aluminium conductors must<br />

be prepared according to the relevant technical<br />

recommendations.<br />

See Technical details for more information about<br />

terminal assignment<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material impact-resistant PC polycarbonate<br />

colour grey, RAL 7032<br />

Order threaded <strong>cable</strong> glands, flanges and other<br />

accessories separately as required<br />

<strong>DK</strong><br />

K 2404 25-240 mm², Cu/Alu, 3~ <br />

4-pole,<br />

2 x 25-185/240 mm² or 4 x 25 - 120 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

<br />

Mi<br />

K 2405 25-240 mm², Cu/Alu, 3~ <br />

5-pole,<br />

2 x 25-185/240 mm² or 4 x 25 - 120 mm²<br />

see Technical details for more information about<br />

terminal assignment<br />

<strong>cable</strong> entry via flange, see accessories<br />

<br />

References/Types<br />

42


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

KF-Cable <strong>junction</strong> <strong>boxes</strong><br />

• degree of protection IP 65<br />

• flame retardant, self-extinguishing,<br />

made of high-grade material:<br />

PC-GFS, glass-fibre reinforced<br />

thermoplastics, impact proof<br />

• Burning behaviour<br />

Glow-wire test 960°C<br />

according to IEC 60 695-2-1,<br />

UL Subject 94: V-0<br />

Degree of protection IP 65<br />

using <strong>cable</strong> glands ASS..<br />

available as an accessory<br />

MC<br />

LES<br />

KF-Cable <strong>junction</strong> <strong>boxes</strong> comply<br />

with regulatory restrictions for buildings<br />

with requirements regarding<br />

the structural fire protection!<br />

halogen-free:<br />

• low toxicity<br />

• low fume development<br />

Degree of protection IP 65<br />

using <strong>cable</strong> glands ASM..<br />

available as an accessory<br />

HENPAS<br />

KF-Cable <strong>junction</strong> <strong>boxes</strong><br />

Weatherproof:<br />

• UV resistant<br />

• rainproof<br />

• temperature resistant<br />

• impact proof<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

43<br />

Technical data<br />

References/Types


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

Service<br />

<strong>DK</strong><br />

with terminals<br />

KF 9025 1.5-2.5 mm², Cu, 3~<br />

4 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol,<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour grey, RAL 7032<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

KF 9045 1.5-4 mm², Cu, 3~<br />

6 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol, 2 x 6 mm² sol,<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KF 9065 2.5-6 mm², Cu, 3~<br />

10 mm², Cu, 1~<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

5-pole,<br />

4 x 2.5 mm² sol, 4 x 4 mm² sol,<br />

3 x 6 mm² sol, 2 x 10 mm² sol,<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

KF 9105 4-10 mm², Cu, 3~<br />

16 mm², Cu, 1~<br />

5-pole,<br />

6 x 2.5 mm² sol, 4 x 4 mm² sol,<br />

4 x 6 mm² sol, 4 x 10 mm² sol, 2 x 16 mm² s<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

KF 9255 10-25 mm², Cu, 3~<br />

35 mm², Cu, 1~<br />

5-pole,<br />

6 x 10 mm² sol, 4 x 16 mm² s,<br />

4 x 25 mm² s, 2 x 35 mm² s,<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

Technical data<br />

KF 9355 16-35 mm², Cu, 3~<br />

mm², Cu,<br />

5-pole,<br />

4 x 16 mm² s, 4 x 25 mm² s,<br />

4 x 35 mm² s,<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

44


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

with terminals<br />

KF 9505 16-50 mm², Cu, 3~<br />

5-pole,<br />

4 x 16 mm² s, 4 x 25 mm² s,<br />

4 x 35 mm² s, 4 x 50 mm² s,<br />

PE max. 35 mm²<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour grey, RAL 7032<br />

<br />

<br />

<br />

<br />

<br />

Service<br />

Technical data<br />

<strong>DK</strong><br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

<br />

<br />

<br />

45<br />

References/Types


KV<br />

Mi<br />

MC<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

Service<br />

without terminals degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour grey, RAL 7032<br />

KF 9020<br />

2.5 mm²<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>DK</strong><br />

KF 9040<br />

4 mm²<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KF 9060<br />

6 mm²<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KF 9100<br />

10 mm²<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

KF 9250<br />

25 mm²<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

KF 9350<br />

35 mm²<br />

<strong>cable</strong> entry: order ASM separately<br />

(refer to index LES)<br />

new<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

46


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

without terminals degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour grey, RAL 7032<br />

KF 9500<br />

50 mm²<br />

<strong>cable</strong> entry order ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

Technical data<br />

Service<br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

47<br />

References/Types


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

Service<br />

<strong>DK</strong><br />

with terminals<br />

KF 5025 1.5-2.5 mm², Cu, 3~<br />

4 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol,<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour black, RAL 9011<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

KF 5045 1.5-4 mm², Cu, 3~<br />

6 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1,5 mm² sol, 4 x 2,5 mm² sol,<br />

3 x 4 mm² sol, 2 x 6 mm² sol,<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KF 5065 2,5-6 mm², Cu, 3~<br />

10 mm², Cu, 1~<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

5-pole,<br />

4 x 2.5 mm² sol, 4 x 4 mm² sol,<br />

3 x 6 mm² sol, 2 x 10 mm² sol,<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

KF 5105 4-10 mm², Cu, 3~<br />

16 mm², Cu, 1~<br />

5-pole,<br />

6 x 2.5 mm² sol, 4 x 4 mm² sol,<br />

4 x 6 mm² sol, 4 x 10 mm² sol, 2 x 16 mm² s<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

KF 5255 10-25 mm², Cu, 3~<br />

35 mm², Cu, 1~<br />

5-pole,<br />

6 x 10 mm² sol, 4 x 16 mm² s,<br />

4 x 25 mm² s, 2 x 35 mm² s,<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

Technical data<br />

KF 5355 16-35 mm², Cu, 3~<br />

5-pole,<br />

4 x 16 mm² s, 4 x 25 mm² s,<br />

4 x 35 mm² s,<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

new<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

48


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

with terminals<br />

KF 5505 16-50 mm², Cu, 3~<br />

5-pole,<br />

4 x 16 mm² s, 4 x 25 mm² s,<br />

4 x 35 mm² s, 4 x 50 mm² s,<br />

PE max. 35 mm²<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

rated insulation voltage AC/DC 690 V<br />

degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour black, RAL 9011<br />

<br />

<br />

<br />

<br />

<br />

Service<br />

Technical data<br />

<strong>DK</strong><br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

<br />

<br />

<br />

49<br />

References/Types


Mi<br />

MC<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

Service<br />

without terminals degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour black, RAL 9011<br />

KF 5020<br />

2.5 mm²<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>DK</strong><br />

KF 5040<br />

4 mm²<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

KF 5060<br />

6 mm²<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KF 5100<br />

10 mm²<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

KF 5250<br />

25 mm²<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

KF 5350<br />

35 mm²<br />

<strong>cable</strong> entry: order ASS separately<br />

(refer to index LES)<br />

new<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

50


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

without terminals degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour black, RAL 9011<br />

KF 5500<br />

50 mm²<br />

<strong>cable</strong> entry order ASS separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

Technical data<br />

Service<br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

51<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

LES<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

box walls without <strong>cable</strong> entry, can be drilled individually<br />

MC<br />

Cable entries can be drilled<br />

individually.<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

HENPAS<br />

Hensel <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> can<br />

in general also be used in poor<br />

environmental conditions by using<br />

IP 65 <strong>cable</strong> glands AKM/ASM.<br />

Labelling system<br />

for circuit description.<br />

References/Types<br />

52


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

box walls without <strong>cable</strong> entry, can be drilled individually<br />

without terminals degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour grey, RAL 7032<br />

KF 8020<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 20<br />

<br />

<br />

<br />

Service<br />

KF 8040<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 20<br />

<br />

<br />

<br />

Technical data<br />

MC<br />

<strong>DK</strong><br />

Mi<br />

KV<br />

KF 8060<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 32<br />

<br />

<br />

<br />

KF 8100<br />

<br />

<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 32<br />

<br />

KF 8250<br />

<br />

<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 40<br />

<br />

LES<br />

KF 8350<br />

new<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 50<br />

<br />

<br />

<br />

HENPAS<br />

53<br />

References/Types


<strong>DK</strong><br />

KV<br />

Mi<br />

MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

box walls without <strong>cable</strong> entry, can be drilled individually<br />

Service<br />

without terminals degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour grey, RAL 7032<br />

KF 8500<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 50<br />

<br />

<br />

References/Types<br />

<br />

54


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

box walls without <strong>cable</strong> entry, can be drilled individually<br />

without terminals degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour black, RAL 9011<br />

KF 4020<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 20<br />

<br />

<br />

<br />

Technical data<br />

Service<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

KF 4040<br />

<br />

<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 20<br />

<br />

KF 4060<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 32<br />

<br />

<br />

<br />

KF 4100<br />

<br />

<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 32<br />

<br />

MC<br />

KF 4250<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 40<br />

<br />

<br />

<br />

LES<br />

KF 4500<br />

wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 50<br />

<br />

<br />

HENPAS<br />

<br />

55<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

LES<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

Approved for United States and Canada (UL/CSA)<br />

MC<br />

Cable <strong>junction</strong> <strong>boxes</strong> with external<br />

brackets made of stainless steel.<br />

Approved for United States<br />

and Canada<br />

HENPAS<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Hensel <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> can<br />

in general also be used in poor<br />

environmental conditions by using<br />

IP 65 <strong>cable</strong> glands AKM/ASM.<br />

Technical data<br />

Labelling system<br />

for circuit description.<br />

References/Types<br />

56


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for outdoor installation<br />

Approved for United States and Canada (UL/CSA)<br />

without terminals<br />

box walls without <strong>cable</strong> entry, can be drilled<br />

individually<br />

degree of protection IP 65 / (Nema 4X)<br />

material impact-resistant thermoplastic<br />

colour grey, RAL 7032<br />

KF 7020 <br />

Wall surface can be drilled individually for <strong>cable</strong><br />

entry max. M 20, NPT 3/8“, NPT ½“,<br />

2 external brackets<br />

<br />

Technical data<br />

Service<br />

HENPAS<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

KF 7040 <br />

Wall surface can be drilled individually for <strong>cable</strong><br />

entry M 20, NPT 3/8“, NPT ½“, ,<br />

2 external brackets<br />

<br />

KF 7060 <br />

Wall surface can be drilled individually for <strong>cable</strong><br />

entry M 20/25/32, NPT 3/8“, NPT ½“, NPT ¾“,<br />

2 external brackets<br />

<br />

<br />

KF 7100 <br />

Wall surface can be drilled individually for <strong>cable</strong><br />

entry M 20/25/32, NPT 3/8“, NPT ½“, NPT ¾“,<br />

NPT 1“<br />

2 external brackets<br />

<br />

MC<br />

KF 7250 <br />

<br />

Wall surface can be drilled individually for <strong>cable</strong><br />

entry M 20/25/32/40, NPT 3/8“, NPT ½“,<br />

NPT ¾“, NPT 1“<br />

4 external brackets<br />

<br />

LES<br />

57<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

tested for functional integrity in the event of fire<br />

<strong>cable</strong> entry via mounted grommets<br />

Technical data HENPAS<br />

LES<br />

MC<br />

Cable <strong>junction</strong> <strong>boxes</strong> IP 65 according<br />

to IEC 60 998-2-5, tested for<br />

functional integrity in the event of a<br />

fire.<br />

FK Cable <strong>junction</strong> <strong>boxes</strong> comply<br />

with these requirements when used<br />

together with type-approved <strong>cable</strong>s<br />

as well as suitable <strong>cable</strong> clamps or<br />

mounting devices.<br />

Cable <strong>junction</strong> <strong>boxes</strong> tested for<br />

functional integrity in the event of<br />

a fire.<br />

Degree of protection IP 65<br />

Box made from sheet steel with<br />

powder coating,<br />

pastel orange RAL 2003<br />

No additional fire load, no toxic or<br />

corrosive emissions.<br />

Functional integrity according to<br />

DIN 4102 part 12 (German standard)<br />

together with functionretaining<br />

<strong>cable</strong>s of 0.5-16 mm 2 .<br />

Protection against direct contact<br />

also maintained due to the box.<br />

Cover with 4 captive screws.<br />

References/Types<br />

58


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

tested for functional integrity in the event of fire<br />

<strong>cable</strong> entry via mounted grommets<br />

degree of protection IP 65<br />

rated insulation voltage AC/DC 400 V<br />

connecting terminal made from ceramic with<br />

resistance to high temperatures<br />

4 mounted grommets IP 65, closed<br />

material sheet steel, powder-coated<br />

colour pastel orange, RAL 2003<br />

mounted using exterior wall fixings<br />

Service<br />

FK 9025<br />

Connection box for 2 <strong>cable</strong>s 0.5-4 mm², Cu<br />

Junction box 0.5-1.5 mm², Cu<br />

5-pole,<br />

2 x 0.5 mm² sol, 2 x 1.5 mm² sol,<br />

1 x 2.5 mm² sol, 1 x 4 mm² sol,<br />

mounted <strong>cable</strong> entry: 4 E<strong>DK</strong> 25<br />

(sealing range Ø 9-17 mm)<br />

<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

<br />

<br />

FK 9105<br />

Connection box for 2 <strong>cable</strong>s 1.5-10 mm², Cu<br />

Junction box 1.5-4 mm², Cu<br />

5-pole,<br />

2 x 1.5 mm² sol, 2 x 2.5 mm² sol, 2 x 4 mm² sol,<br />

1 x 6 mm² sol, 1 x 10 mm² sol,<br />

mounted <strong>cable</strong> entry: 4 E<strong>DK</strong> 32<br />

(sealing range Ø 12-23 mm)<br />

<br />

<br />

<br />

FK 9255<br />

Connection box for 2 <strong>cable</strong>s 1.5-16 mm², Cu<br />

Junction box 1.5-6 mm², Cu<br />

5-pole,<br />

2 x 1.5 mm² sol, 2 x 2.5 mm² sol, 2 x 4 mm² sol,<br />

2 x 6 mm² sol, 1 x 10 mm² sol, 1 x 16 mm² sol<br />

mounted <strong>cable</strong> entry: 4 E<strong>DK</strong> 40<br />

(sealing range Ø 17-30 mm)<br />

<br />

<br />

<br />

MC<br />

Type<br />

Functional<br />

integrity class<br />

Terminals /<br />

number of conductors<br />

Current carrying<br />

capacity<br />

Cross-section<br />

<strong>cable</strong><br />

manufacturer<br />

Cable type (as at 5/03)<br />

LES<br />

Power <strong>cable</strong><br />

32 A 1.5 mm 2 ; 2.5 mm 2 ; 4 mm 2 Dätwyler<br />

FK 9025 E 30 Connection<br />

1.5 mm 2 Pirelli<br />

1.5-4 mm 2<br />

Junction<br />

Nexans<br />

Pyrofil Keram NHXH FE 180 / ...<br />

Rheyhalon KF2U-FIM E30; N2XH-J FE 180;<br />

KF2U-FXVM E 90<br />

SIENOPYR-PLUS NHXH-J / E 30<br />

40 A 1.5 mm 2 ; 2.5 mm 2 ; 4 mm 2 Dätwyler<br />

FK 9105 E 30 Connection<br />

1.5-4 mm 2 Pirelli<br />

Junction<br />

1.5 mm 2 ; 2.5 mm 2 ; 4 mm 2 Nexans<br />

1.5-10 mm 2<br />

6 mm 2 ; 10 mm 2<br />

Nexans<br />

63 A 1.5 mm 2 ; 2.5 mm 2 ; 4 mm 2 Dätwyler<br />

FK 9255 E 30 Connection<br />

1.5-6 mm 2 Pirelli<br />

Junction<br />

1.5 mm 2 ; 2.5 mm 2 ; 4 mm 2 Nexans<br />

1.5-16 mm 2<br />

6 mm 2 ; 10 mm 2 ; 16 mm 2 Nexans<br />

Pyrofil Keram NHXH FE 180 / ...<br />

Rheyhalon KF2U-FIM E30; N2XH-J FE 180<br />

Rheyhalon KF2U-FXVM E 90<br />

SIENOPYR-PLUS NHXH-J/ E 30<br />

Pyrofil Keram NHXH FE 180 / ...<br />

Rheyhalon KF2U-FIM E30; N2XH-J FE 180<br />

Rheyhalon KF2U-FXVM E 90<br />

SIENOPYR-PLUS NHXH-J/ E 30<br />

HENPAS<br />

32 A 1.5 mm 2 ; 2.5 mm 2 ; 4 mm 2 Dätwyler<br />

FK 9025 E 90 Connection<br />

1,5 mm 2<br />

1.5-4 mm 2<br />

Junction<br />

1.5 mm 2 Nexans<br />

Eupen<br />

FK 9105<br />

FK 9255<br />

Control <strong>cable</strong><br />

E 90<br />

Connection FK 9105: 40 A<br />

1.5-4 mm 2 FK 9255: 63 A<br />

Junction<br />

1.5-4 mm 2<br />

1.5 mm 2 ; 2.5 mm 2 ; 4 mm 2 Dätwyler<br />

1.5 mm 2 Nexans<br />

Eupen<br />

Pyrofil Keram NHXH FE 180 / E 90<br />

Rheyhalon N2XH-J FE 180; KF2U-FXVM E 90<br />

NHXH FE 180<br />

Pyrofil Keram NHXH FE 180 / E 90<br />

Rheyhalon N2XH-J FE 180; KF2U-FXVM E 90<br />

NHXH FE 180<br />

Technical data<br />

FK 9025<br />

E 30 und<br />

E 60<br />

Connection<br />

0.5 mm 2<br />

Ø 0.8 mm<br />

Junction<br />

0.5 mm 2<br />

Ø 0.8 mm<br />

32 A Ø 0.8 mm (0.5 mm 2 ) Dätwyler<br />

Nexans<br />

Studer AG<br />

Lynenwerk 2000<br />

FK 9025 E 90 32 A Ø 0.8 mm (0.5 mm 2 ) Dätwyler<br />

Nexans<br />

Profil Keram JE-H(ST)H BD FE 180 ...<br />

Rheyhalon VDE.. JE-H(ST)H ...<br />

JE-H(St)H / E 90<br />

JE-H(St)H / E 90<br />

Profil Keram JE-H(ST)H BD FE 180 / E 90<br />

Rheyhalon VDE.. JE-H(ST)H / E 90<br />

59<br />

References/Types


KV<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

tested for functional integrity in the event of fire<br />

<strong>cable</strong> entry via mounted grommets<br />

Service<br />

<strong>cable</strong> <strong>junction</strong> box with fused outgoing<br />

circuit<br />

functional integrity E 30 following DIN 4102<br />

Part 12<br />

degree of protection IP 65<br />

rated insulation voltage AC 400 V<br />

terminal block made from ceramic with resistance<br />

to high temperatures<br />

D 01 neozed fuse base<br />

material sheet steel, powder-coated<br />

colour pastel orange, RAL 2003<br />

4 mounted E<strong>DK</strong> grommets IP 65, closed<br />

mounted using exterior wall fixings<br />

<strong>DK</strong><br />

FK 9259 1.5-10 mm², Cu <br />

5-pole,<br />

2 connection terminals<br />

2 <strong>junction</strong> terminals<br />

2 PE terminals<br />

each 1.5-10 mm² sol<br />

<strong>cable</strong> entry 4 E<strong>DK</strong> 40<br />

(sealing range Ø 17-30 mm)<br />

<br />

Type<br />

Functional<br />

integrity class<br />

Terminals /<br />

number of conductors<br />

Current carrying<br />

capacity<br />

Cross-section<br />

<strong>cable</strong><br />

manufacturer<br />

Cable type (as at 5/03)<br />

Mi<br />

Supply <strong>cable</strong><br />

FK 9259 E 30 connection 40 A 1.5 - 10 mm 2 Dätwyler<br />

1.5-10 mm 2 Nexans<br />

Pyrofil Keram NHXH FE 180 / ...<br />

Rheyhalon KF2U-FIM E30;<br />

N2XH-J FE 180; KF2U-FXVM E 90<br />

MC<br />

FK 9259, with fused outgoing circuit<br />

Can be used in emergency lighting in installations that<br />

cover a large area (e.g. tunnels).<br />

The use of a fused branch circuit makes it possible to<br />

supply a group of emergency luminaires with one supply<br />

lead.<br />

If one or several emergency luminaires are damaged<br />

during a fire, the back-up fuse is tripped and ensures<br />

that the power supply of the common supply lead is<br />

maintained.<br />

<br />

<br />

<br />

<br />

<br />

FK 9259<br />

Note<br />

selectivity of<br />

protective<br />

system<br />

<br />

<br />

LES<br />

The use of this equipment requires approval from<br />

the planning department and building control<br />

office for individual cases.<br />

Load<br />

Emergency<br />

luminaire<br />

References/Types<br />

60


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for hazardous areas to be used in zone 2 and zone 22<br />

<strong>cable</strong> entry via metric knockouts<br />

new<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

In areas with an explosive<br />

atmosphere within the European<br />

Union only materials that comply<br />

with EU directive 94/9/EG<br />

(ATEX 100a) must be installed<br />

and meet with the corresponding<br />

national standards and regulations.<br />

Selection of equipment:<br />

1.<br />

The proprietor specifies the separation<br />

into explosive areas (dust/gas),<br />

the zones and the type of material<br />

(atmosphere/dust) with flash point,<br />

ignition temperature, conductive or<br />

non-conductive.<br />

Degree of protection IP 65<br />

using <strong>cable</strong> glands AXM..<br />

available as an accessory<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

MC<br />

LES<br />

HENPAS<br />

2.<br />

This information must be used to<br />

define the requirements in regard to<br />

selecting the right equipment.<br />

3.<br />

The device ID must provide information<br />

about where and in which<br />

areas the equipment must be used<br />

(device category and, consequently,<br />

allocation to the hazard zone).<br />

ATEX E-mail:<br />

info@hensel-atex.de<br />

www.hensel-atex.de<br />

61<br />

Technical data<br />

References/Types


Mi<br />

HENPAS<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for hazardous areas to be used in zone 2 and zone 22<br />

<strong>cable</strong> entry via metric knockouts<br />

Service<br />

in accordance with ATEX 100a<br />

with terminals<br />

Protection type EExn IIA 3GD T 80° C (T6)<br />

rated insulation voltage AC 690 V<br />

degree of protection IP 65<br />

material impact-resistant thermoplastic<br />

colour black, RAL 9011<br />

KX 2025 1.5-2.5 mm², Cu, 3~<br />

<br />

<br />

<br />

<br />

<strong>DK</strong><br />

4 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol,<br />

<strong>cable</strong> entry: order AXM separately<br />

<br />

<br />

<br />

<br />

KV<br />

KX 2045 1.5-4 mm², Cu, 3~<br />

6 mm², Cu, 1~ <br />

5-pole,<br />

6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol, 2 x 6 mm² sol,<br />

<strong>cable</strong> entry: order AXM separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KX 2065 2.5-6 mm², Cu, 3~<br />

10 mm², Cu, 1~<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

5-pole,<br />

4 x 2.5 mm² sol, 4 x 4 mm² sol,<br />

3 x 6 mm² sol, 2 x 10 mm² sol,<br />

<strong>cable</strong> entry: order AXM separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

KX 2105 4-10 mm², Cu, 3~<br />

16 mm², Cu, 1~<br />

5-pole,<br />

6 x 2.5 mm² sol, 4 x 4 mm² sol,<br />

4 x 6 mm² sol, 4 x 10 mm² sol, 2 x 16 mm² s<br />

<strong>cable</strong> entry: order AXM separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Technical data<br />

KX 2255 10-25 mm², Cu, 3~<br />

35 mm², Cu, 1~<br />

5-pole,<br />

6 x 10 mm² sol, 4 x 16 mm² s,<br />

4 x 25 mm² s, 2 x 35 mm² s,<br />

<strong>cable</strong> entry: order AXM separately<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

62


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for hazardous areas to be used in zone 2 and zone 22<br />

Cable glands<br />

Cable glands<br />

for hazardous areas,<br />

to be used in zone 2 and zone 22<br />

with strain relief and locknut<br />

material Polyamide<br />

degree of protection IP 65<br />

colour black, RAL 9005<br />

Service<br />

AXM 20<br />

AXM 25<br />

AXM 32<br />

AXM 40<br />

ISO thread<br />

M 20 x 1.5<br />

ISO thread<br />

M 25 x 1.5<br />

ISO thread<br />

M 32 x 1.5<br />

ISO thread<br />

M 40 x 1.5<br />

sealing range<br />

Ø 5.5-13 mm<br />

sealing range<br />

Ø 8-17 mm<br />

sealing range<br />

Ø 12-21 mm<br />

sealing range<br />

Ø 17-28 mm<br />

bore-hole<br />

Ø 20.5 mm<br />

bore-hole<br />

Ø 25.5 mm<br />

bore-hole<br />

Ø 32.5 mm<br />

bore-hole<br />

Ø 40.5 mm<br />

wall thickness<br />

min. 1.5 - 2 mm<br />

wall thickness<br />

min. 1.5 - 2 mm<br />

wall thickness<br />

min. 1.5 - 3 mm<br />

wall thickness<br />

min. 1.5 - 3 mm<br />

new<br />

new<br />

new<br />

new<br />

<strong>DK</strong><br />

Technical data<br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

KV<br />

63<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

LES<br />

HENPAS<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for special applications<br />

<strong>cable</strong> entry via metric knockouts<br />

MC<br />

Cable <strong>junction</strong> <strong>boxes</strong> for security<br />

lighting circuits with red lid.<br />

Terminal box for equipotential<br />

bonding <strong>cable</strong>s.<br />

Degree of protection IP 65<br />

using <strong>cable</strong> glands ASM..<br />

available as an accessory<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Technical data<br />

Labelling system<br />

for circuit description.<br />

References/Types<br />

64


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for special applications<br />

<strong>cable</strong> entry via metric knockouts<br />

for safety lighting circuits<br />

with red lid RAL 3000<br />

D 9220 2.5 mm², 3~<br />

4 mm², 1~ <br />

without terminals<br />

included <strong>cable</strong> entry 4 ESM 20<br />

(sealing range Ø 6-13 mm)<br />

degree of protection IP 55 (ESM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Service<br />

<strong>DK</strong><br />

D 9225 1.5-2.5 mm², Cu, 3~<br />

<br />

<br />

<br />

<br />

4 mm², Cu, 1~ <br />

rated insulation voltage AC/DC 690 V<br />

with terminals<br />

5-pole, 6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol<br />

included <strong>cable</strong> entry 4 ESM 20<br />

(sealing range Ø 6-13 mm)<br />

<br />

<br />

<br />

<br />

KV<br />

D 9240 4 mm², 3~<br />

6 mm², 1~ <br />

without terminals<br />

included <strong>cable</strong> entry 4 ESM 25<br />

(sealing range Ø 9-17 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

LES<br />

Technical data<br />

HENPAS<br />

MC<br />

D 9245 1.5-4 mm², Cu, 3~<br />

6 mm², Cu, 1~ <br />

rated insulation voltage AC/DC 690 V<br />

with terminals<br />

5-pole, 6 x 1.5 mm² sol, 4 x 2.5 mm² sol,<br />

3 x 4 mm² sol<br />

included <strong>cable</strong> entry 4 ESM 25<br />

(sealing range Ø 9-17 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

65<br />

References/Types


<strong>DK</strong><br />

KV<br />

Mi<br />

MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

for equipotential bonding conductors<br />

<strong>cable</strong> entry via removable grommets<br />

Service<br />

degree of protection IP 54<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

DP 9026 1-pole <br />

for 1 x continued conductor 4-25 mm² and<br />

5 conductors 4-10 mm² (16 mm² sol)<br />

included <strong>cable</strong> entry 4 DPS 02<br />

(sealing range Ø 10-13,5 mm)<br />

<br />

References/Types<br />

66


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with main line branch terminals for copper conductors<br />

<strong>cable</strong> entry via metric knockouts<br />

Technical data<br />

HENPAS<br />

LES<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

Degree of protection IP 65<br />

using <strong>cable</strong> glands ASM..<br />

available as an accessory<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

MC<br />

Labelling system<br />

for circuit description.<br />

67<br />

References/Types


MC<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with main line branch terminals for copper conductors<br />

<strong>cable</strong> entry via metric knockouts<br />

Service<br />

with lead seal<br />

rated insulation voltage AC 400 V<br />

degree of protection IP 55 (ESM)<br />

degree of protection IP 65 (refer to index LES)<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<strong>DK</strong><br />

K 9259 25 mm², Cu, 3~<br />

4-pole,<br />

1 x 25 mm² r, incoming <strong>cable</strong><br />

4 x 16 mm² r, outgoing <strong>cable</strong><br />

included <strong>cable</strong> entry 3 ESM 40<br />

(sealing range Ø 17-30 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

K 9508 25 mm², Cu, 3~<br />

4-pole,<br />

1 x 25 mm² r, incoming <strong>cable</strong><br />

4 x 16 mm² r, outgoing <strong>cable</strong><br />

<strong>cable</strong> entry: order AKM/ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

K 9509 25/35 mm², Cu, 3~<br />

4-pole,<br />

2 x 35 mm² r, incoming <strong>cable</strong><br />

4 x 35 mm² r, outgoing <strong>cable</strong><br />

<strong>cable</strong> entry: order AKM/ASM separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

68


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with terminal blocks for aluminium- (Alu) and copper conductors (Cu)<br />

<strong>cable</strong> entry via metric knockouts<br />

HENPAS<br />

LES<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

Stainless steel cover screws with<br />

quick fastening metric thread.<br />

Reducing cover fixing time.<br />

Degree of protection IP 55<br />

using grommets ESM ...<br />

available as an accessory<br />

MC<br />

Labelling system<br />

for circuit description.<br />

Degree of protection IP 65<br />

using <strong>cable</strong> glands AKM..<br />

available as an accessory<br />

Other terminal sets available<br />

on request.<br />

Technical data<br />

69<br />

References/Types


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with terminal blocks for aluminium- (Alu) and copper conductors (Cu)<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

Service<br />

terminal blocks, by Wieland<br />

for aluminium and copper conductors<br />

terminal marking, neutral<br />

order <strong>cable</strong> entry glands separately<br />

see Technical details for more information about<br />

terminal assignment<br />

degree of protection IP 65<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

<strong>DK</strong><br />

RD 9123<br />

1.5-2.5 mm²<br />

with external fixing<br />

3 terminals type WKM 2.5/15<br />

rated insulation voltage AC/DC 500 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

RD 9125<br />

1.5-2.5 mm²<br />

with external fixing<br />

5 terminals type WKM 2.5/15<br />

rated insulation voltage AC/DC 500 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

RD 9127<br />

1.5-2.5 mm²<br />

with external fixing<br />

7 terminals type WKM 2.5/15<br />

rated insulation voltage AC/DC 500 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

MC<br />

RD 9045<br />

1.5-4 mm²<br />

5 terminals type WKM 4/15<br />

rated insulation voltage AC/DC 500 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

RD 9041<br />

1.5-4 mm²<br />

10 terminals type WKM 4/15<br />

rated insulation voltage AC/DC 500 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

RK 9062<br />

1.5-4 mm²<br />

12 terminals type WK 4/U<br />

rated insulation voltage AC/DC 690 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Technical data<br />

RK 9064<br />

1.5-4 mm²<br />

14 terminals type WK 4/U<br />

rated insulation voltage AC/DC 690 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

70


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

with terminal blocks for aluminium- (Alu) and copper conductors (Cu)<br />

<strong>cable</strong>/conduit entry via metric knockouts<br />

terminal blocks, by Wieland<br />

for aluminium and copper conductors<br />

terminal marking, neutral<br />

order <strong>cable</strong> entry glands separately<br />

see Technical details for more information about<br />

terminal assignment<br />

degree of protection IP 65<br />

material thermoplastic<br />

colour grey, RAL 7035<br />

Service<br />

RK 9109<br />

1.5-4 mm²<br />

19 terminals type WK 4/U<br />

rated insulation voltage AC/DC 690 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>DK</strong><br />

RK 9104<br />

1.5-4 mm²<br />

24 terminals type WK 4/U<br />

rated insulation voltage AC/DC 690 V<br />

order <strong>cable</strong> entry glands separately<br />

(refer to index LES)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

Technical data<br />

HENPAS<br />

<br />

LES<br />

MC<br />

Mi<br />

<br />

<br />

71<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Mi<br />

LES<br />

HENPAS<br />

Technical data<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Accessories<br />

MC<br />

DIN rails 73<br />

Terminal sets 74<br />

Accessories 75<br />

Accessories for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> ≥ 70 mm 2 76<br />

References/Types<br />

72


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Accessories<br />

DIN rails<br />

for the installation of terminal blocks<br />

for insertion in empty <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

with fixing screws<br />

TSD 02 DIN rail <br />

max. installation depth 32 mm<br />

<br />

<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> D x020, D x120, KF x020<br />

<br />

top hat profile 15 mm according to EN 50 045<br />

TSD 04 DIN rail <br />

<br />

max. installation depth 40 mm<br />

<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> D x040, KF x040<br />

<br />

top hat profile 15 mm according to EN 50 045<br />

<br />

<br />

Service<br />

<strong>DK</strong><br />

TSK 06<br />

TSK 10<br />

DIN rail<br />

max. installation depth 44,5 mm<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K x060, KF x060<br />

top hat profile 15 mm according to EN 50 045<br />

DIN rail<br />

max. installation depth 56,5 mm<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K x100, KF x100<br />

top hat profile 15 mm according to EN 50 045<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KV<br />

TSK 25<br />

DIN rail<br />

max. installation depth 71,5 mm<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K x250, KF x250<br />

top hat profile 15 mm according to EN 50 045<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

TSK 50<br />

DIN rail<br />

max. installation depth 87,5 mm<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K x500, KF x500<br />

top hat profile 15 mm according to EN 50 045<br />

MC<br />

Technical data<br />

HENPAS<br />

LES<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

73<br />

References/Types


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Accessories<br />

Terminal sets<br />

for insertion in <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

complete with fixing elements<br />

<strong>DK</strong><br />

Service<br />

<strong>DK</strong>L 04<br />

terminal set 1.5-6 mm², Cu <br />

5-pole, each<br />

6 x 1.5 mm² sol<br />

4 x 2.5 mm² sol<br />

3 x 4 mm² sol<br />

2 x 6 mm² sol<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> D 8020, D 8120, D 8040, D 9020,<br />

D 9120, D 9040, D 9220, DP 9020, DP 9220, DE 9320,<br />

DE 9321, DE 9340, DE 9341, KF 5020, KF 5040, KF 8020,<br />

KF 9020, KF 9040<br />

KV<br />

KKL 06<br />

terminal set 2.5-10 mm², Cu <br />

5-pole, each<br />

4 x 2.5 mm² sol<br />

4 x 4 mm² sol<br />

3 x 6 mm² sol<br />

2 x 10 mm² sol<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K 8060, K 9060, KF 5060, KF 8060,<br />

KF 9060<br />

Mi<br />

KLS 10<br />

terminal set 2.5-16 mm², Cu <br />

current carrying capacity 63 A<br />

5-pole, each<br />

6 x 2,5 mm² sol<br />

4 x 4 mm² sol<br />

4 x 6 mm² sol<br />

4 x 10 mm² sol<br />

2 x 16 mm² s<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K 8100, K 9100, KF 5100, KF 8100,<br />

KF 9100<br />

LES<br />

MC<br />

KLS 25<br />

terminal set 6-35 mm², Cu <br />

current carrying capacity 102 A<br />

5-pole, each<br />

6 x 6 mm² sol<br />

6 x 10 mm² sol, f*<br />

4 x 16 mm² sol, f*<br />

4 x 25 mm² sol, f*<br />

2 x 35 mm² sol, f*<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K 8250, K 8500, K 9250, K 9500,<br />

KF 5250, KF 5500, KF 8250, KF 8500, KF 9250, KF 9500<br />

f* = with gas-tight end ferrule<br />

HENPAS<br />

Technical data<br />

References/Types<br />

74<br />

KLS 54<br />

KLS 55<br />

terminal set 16-50 mm², Cu<br />

current carrying capacity 216 A<br />

4-pole, each<br />

4 x 16 mm² s<br />

4 x 25 mm² s<br />

4 x 35 mm² s<br />

4 x 50 mm² s<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K 8500, K 9500, KF 5500, KF 8500,<br />

KF 9500<br />

terminal set 16-50 mm², Cu<br />

current carrying capacity 170 A<br />

5-pole<br />

4 x 16 mm² s<br />

4 x 25 mm² s<br />

4 x 35 mm² s<br />

4 x 50 mm² s<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> K 8500, K 9500, KF 5500, KF 8500,<br />

KF 9500<br />

89 A<br />

PE<br />

35 mm²<br />

50 mm²


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Accessories<br />

<strong>DK</strong> AL 2<br />

external brackets<br />

for external wall fixing of <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> type D, K, KF<br />

2 external brackets<br />

material V2A stainless steel<br />

Service<br />

DPS 02<br />

EKA 20<br />

ERA 20<br />

<strong>DK</strong> BS 5<br />

PLS 06<br />

PLS 50<br />

removable grommet<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> DP 9020, DP 9220, DP 9025,<br />

DP 9221, DP 9222, DP 9026<br />

degree of protection IP 54<br />

sealing range 10-13.5 mm<br />

removable trunking adapter<br />

for mini trunking up to 20 x 20 mm<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> DP 9020, DP 9220, DP 9025,<br />

DP 9221, DP 9222, DP 9026<br />

degree of protection IP 54<br />

removable conduit adapter<br />

for wiring conduits M 20<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> DP 9020, DP 9220, DP 9025,<br />

DP 9221, DP 9222, DP 9026<br />

degree of protection IP 54<br />

labelling system for circuit description<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> from 2.5 to 50 mm²,<br />

can be inserted into cover fixing ducts<br />

for attaching of labelling strips or marking with felt tip pen<br />

cannot be used with <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> 2.5 to 4 mm²<br />

with seal<br />

material thermoplastic<br />

set with 5 pieces<br />

45 x 30 mm<br />

lead sealing<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> 2.5 mm²:<br />

D 9x2x, D 8x2x, DE 9x2x, DP 9x2x, KF 9x2x, KF 8x2x,<br />

KF 7x2x, KF 5x2x, RD 9x2x<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> 4 mm²:<br />

D 9x4x, D 8x4x, DE 9x4x, KF 9x4x, KF 8x4x, KF 7x4x,<br />

KF 5x4x, RD 9x4x<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> 6 mm²:<br />

K 9x6x, K 8x6x, KF 9x6x, KF 8x6x, KF 7x6x, KF 5x6x,<br />

RD 9x6x<br />

lead sealing<br />

new<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> 10 mm²:<br />

K 91xx, K 81xx, KF 91xx, KF 81xx, KF 71xx, KF 51xx<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> 25 mm²:<br />

K 925x, K 825x, KF, 925x, KF 825x, KF 725x, KF 525x,<br />

RK 91xx<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> 35/50 mm²: K 93xx, K 95xx, K 83xx,<br />

K 85xx, KF 93xx, KF 95xx, KF 83xx, KF 85xx, KF 53xx,<br />

KF 55xx, KF 45xx<br />

The following <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> and main line <strong>junction</strong><br />

<strong>boxes</strong> are fitted with sealable covers as standard:<br />

K 7004, K 7005, K 7042, K 7052, K 1204, K 1205, K 2404,<br />

K 2405, K 9259, K 9508, K 9509.<br />

Technical data HENPAS<br />

LES<br />

MC<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

75<br />

References/Types


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Accessories<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> from 70 mm 2 onwards<br />

Service<br />

Mi AL 4<br />

external brackets<br />

for <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> 70 -240 mm²<br />

for external box fixing<br />

set consisting of 4 fixing brackets,<br />

4 screws<br />

<strong>DK</strong><br />

Mi FM 32 flange <br />

<br />

with fixing wedges and seal<br />

<strong>cable</strong> entry 8 x M 25/32, 1 x M 25/32/40<br />

box wall 300 mm<br />

KV<br />

Mi FM 40 flange <br />

<br />

with fixing wedges and seal<br />

<strong>cable</strong> entry 2 x M 25/32, 5 x M 32/40<br />

box wall 300 mm<br />

Mi<br />

Mi FM 50 flange <br />

<br />

with fixing wedges and seal<br />

<strong>cable</strong> entry 2 x M 20, 4 x M 32/40/50<br />

box wall 300 mm<br />

Mi FM 60 flange <br />

<br />

with fixing wedges and seal<br />

<strong>cable</strong> entry 3 x M 40/50/63,<br />

box wall 300 mm<br />

MC<br />

Mi FM 63<br />

flange<br />

with extended <strong>cable</strong> arrangement space<br />

with fixing wedges and seal<br />

<strong>cable</strong> entry 3 x M 40/50/63,<br />

box wall 300 mm<br />

<br />

<br />

LES<br />

Mi FP 82 <strong>cable</strong> insert <br />

for 2 <strong>cable</strong>s<br />

max. 72 mm external diameter<br />

degree of protection IP 54 only with additional strain<br />

relief (e.g. Mi ZE 62)<br />

sealing range 30-72 mm<br />

box wall 300 mm<br />

<br />

<br />

HENPAS<br />

Technical data<br />

Mi ZE 62<br />

Mi SA 2<br />

<strong>cable</strong> strain relief<br />

for 2 <strong>cable</strong>s with max. 60 mm external diameter<br />

with fixing rail 284 mm long<br />

to be used only in connection with <strong>cable</strong> insertion Mi FP 82<br />

dust protection cover<br />

for 2 lid fittings<br />

set consisting of 4 parts<br />

References/Types<br />

76


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

MC<br />

Technical data<br />

HENPAS<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

Dimensions in mm 78-79<br />

Terminals 80-82<br />

Operating and ambient conditions 83<br />

Characteristics of the Material 83<br />

Standards and regulations 84<br />

FK <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> with functional integrity 85<br />

Hazardous areas in accordance with ATEX 100a 86-87<br />

LES<br />

77<br />

References/Types


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Dimensions in mm<br />

Service<br />

D 6020<br />

D 8020<br />

D 9020<br />

D 9220<br />

KF 4020<br />

KF 5020<br />

KF 7020<br />

KF 8020<br />

KF 9020<br />

DM 9020<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 6100<br />

K 8100<br />

K 9100<br />

KF 4100<br />

KF 5100<br />

KF 7100<br />

KF 8100<br />

KF 9100<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>DK</strong><br />

KV<br />

D 6120<br />

D 8120<br />

D 9120<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 6250<br />

K 8250<br />

K 9250<br />

KF 4250<br />

KF 5250<br />

KF 7250<br />

KF 8250<br />

KF 9250<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Mi<br />

MC<br />

D 6040<br />

D 9040<br />

KF 5040<br />

KF 9040<br />

DM 9040<br />

DM 9140<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 9350<br />

KF 9350<br />

KF 8350<br />

KF 5350<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

LES<br />

D 8040<br />

KF 4040<br />

KF 7040<br />

KF 8040<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

Technical data<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 6060<br />

K 8060<br />

K 9060<br />

KF 4060<br />

KF 5060<br />

KF 7060<br />

KF 8060<br />

KF 9060<br />

KM 9060<br />

<br />

K 6500<br />

K 8500<br />

K 9500<br />

KF 4500<br />

KF 5500<br />

KF 8500<br />

KF 9500<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

References/Types<br />

78<br />

<br />

<br />

<br />

<br />

= usable installation space<br />

when <strong>cable</strong> glands are attached


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Dimensions in mm<br />

DE 9320<br />

DE 9321<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 7004<br />

K 7005<br />

K 7042<br />

K 7052<br />

K 1204<br />

K 1205<br />

<br />

<br />

<br />

<br />

<br />

Service<br />

<br />

MC<br />

KV<br />

Mi<br />

<strong>DK</strong><br />

DE 9340<br />

DE 9341<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

DP 9020<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K 2404<br />

K 2405<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

DP 9220<br />

<br />

<br />

<br />

LES<br />

<br />

<br />

<br />

<br />

<br />

<br />

HENPAS<br />

DN 2000/<br />

DN 2030<br />

<br />

<br />

<br />

<br />

<br />

<br />

Technical data<br />

<br />

<br />

<br />

<br />

<br />

= usable installation space<br />

when <strong>cable</strong> glands are attached<br />

79<br />

References/Types


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Terminals<br />

Connecting terminals for copper conductors (Cu)<br />

References/Types Technical data HENPAS<br />

LES<br />

MC<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

Type<br />

of terminal<br />

<strong>DK</strong>L 04<br />

KKL 06<br />

KLS 10<br />

KLS 25<br />

KLS 54<br />

KLS 55<br />

80<br />

Fixed in <strong>cable</strong><br />

<strong>junction</strong> <strong>boxes</strong><br />

D 9025<br />

D 9125<br />

D 9225<br />

D 9245<br />

D 9045<br />

DP 9025<br />

DP 9221<br />

DP 9222<br />

DE 9325<br />

DE 9326<br />

DE 9345<br />

DE 9346<br />

DM 9025<br />

DM 9045<br />

DM 9145<br />

DN 2035<br />

KF 5025<br />

KF 5045<br />

KF 9025<br />

KF 9045<br />

KX 2025<br />

KX 2045<br />

K 9065<br />

KF 5065<br />

KF 9065<br />

KM 9065<br />

KX 2065<br />

K 8105<br />

K 9105<br />

KF 5105<br />

KF 9105<br />

KX 2105<br />

K 8255<br />

K 9255<br />

K 9502<br />

KF 5255<br />

KF 9255<br />

KX 2255<br />

K 9504<br />

K 7004<br />

K 7005<br />

K 9505<br />

KF 5505<br />

KF 9505<br />

K 9355<br />

KF 9355<br />

KF 5355<br />

K 9259<br />

K 9508<br />

K 9509<br />

K 9508<br />

Clamping<br />

units<br />

per pole<br />

1<br />

1<br />

2<br />

2<br />

4<br />

4<br />

incoming 2<br />

outgoing 2<br />

incoming 2<br />

outgoing 4<br />

incoming 2<br />

outgoing 4<br />

Rated connecting<br />

capacity<br />

mm 2 and types<br />

of conductors<br />

6 sol<br />

4 sol<br />

2,5 sol<br />

1,5 sol<br />

10 sol<br />

6 sol<br />

4 sol<br />

2,5 sol<br />

Conductors to<br />

be connected<br />

per pole<br />

1-2<br />

1-3<br />

1-4<br />

1-6<br />

1-2<br />

1-3<br />

1-4<br />

1-4<br />

16 s 1-2<br />

10 sol 1-4<br />

6 sol 1-4<br />

4 sol 1-4<br />

2,5 sol, f 1 2-6<br />

35 s, f 1<br />

25 s, f 1<br />

16 s, f 1<br />

10 sol, f 1<br />

6 sol<br />

70 s<br />

50 s<br />

35 s<br />

25 s<br />

16 s<br />

50 s<br />

35 s<br />

25 s<br />

16 s<br />

35 r<br />

35 r<br />

25 r<br />

16 r<br />

35 r<br />

35 r<br />

1-2<br />

1-4<br />

1-4<br />

1-6<br />

1-6<br />

1-4<br />

1-4<br />

1-4<br />

1-4<br />

1-4<br />

1-4<br />

1-4<br />

1-4<br />

1-4<br />

1-2<br />

1-2<br />

1-2<br />

1-4<br />

1-2<br />

1-4<br />

Tightening<br />

torque<br />

Current<br />

carrying<br />

capacity<br />

1,5 Nm – 6 mm 2<br />

1,5 Nm – 10 mm 2<br />

2 Nm 63 A 16 mm 2<br />

3 Nm 102 A 35 mm 2<br />

6 Nm 216 A 70 mm 2<br />

6 Nm<br />

4 Nm<br />

3 Nm<br />

170 A<br />

L1-3<br />

+ N<br />

100 A 35 mm 2<br />

3 Nm 80 A 25 mm 2<br />

4 Nm<br />

3 Nm<br />

terminal for equipotential bonding:<br />

DP 9026 for 1 continued conductor 4-25 mm 2 and 5 conductors 4-10 mm 2 (16 mm 2 sol)<br />

100 A 35 mm 2<br />

Rated cross section of terminal<br />

35 mm 2 89 A 50 mm 2<br />

(PE)<br />

Hint: The connection of different types of conductors and/or different cross-sections at one clamping unit is not permitted.


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Terminals<br />

Terminal blocks for copper- (Cu) and aluminium conductors (Alu)<br />

Fixed in<br />

<strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

Type<br />

Clamping<br />

units<br />

per<br />

pole<br />

corresponding<br />

crosssection<br />

mm²<br />

Conductors<br />

to be<br />

connected<br />

per<br />

pole<br />

Cross-sections and<br />

types of conductors<br />

f = flexible wire<br />

f 1 = flexible wire with<br />

end ferrule<br />

sol = solid wire<br />

s = stranded wire<br />

Tightening<br />

torque<br />

Current<br />

carrying<br />

capacity<br />

Terminal<br />

design/<br />

nominal<br />

cross-section<br />

of terminal<br />

International<br />

approvals of<br />

terminal blocks<br />

CH/SEV<br />

N/Nemko<br />

<strong>DK</strong>/Demko<br />

NL/KEMA<br />

SF/SETI<br />

Canada/CSA<br />

USA/<br />

Service<br />

Manufacturer Weidmüller:<br />

D 9041 AKZ 2,5<br />

rated voltage<br />

AC/DC 250 V<br />

4 2,5<br />

1,5<br />

4 f/f 1 sol = 0,5-2,5<br />

s = 1,5-2,5<br />

0,5 Nm 20 A • • • •<br />

<strong>DK</strong><br />

K 9061 AKZ 4<br />

rated voltage<br />

AC/DC 400 V<br />

4 4<br />

2,5<br />

1,5<br />

4 f/sol = 0,5-4<br />

s = 1,5-4<br />

f 1 = 0,5-2,5<br />

0,6 Nm 20 A • • • • • •<br />

K 9101 WDU 6<br />

rated voltage<br />

AC/DC 690 V<br />

4 6<br />

4<br />

4 f/sol = 0,5-10<br />

s = 1,5-10<br />

f 1 = 0,5-6<br />

1,2 Nm 41 A • • • • • • •<br />

KV<br />

K 9251<br />

WDU 16 N<br />

rated voltage<br />

AC/DC 400 V<br />

4 16<br />

10<br />

6<br />

4 f 1 /sol = 1,5-16<br />

f/s = 1,5-25<br />

3,0 Nm 76 A • • • • • •<br />

Technical data<br />

HENPAS<br />

Mi<br />

K 9501 WDU 35<br />

rated voltage<br />

AC/DC 690 V<br />

4 35<br />

25<br />

16<br />

4 sol = 2,5-16<br />

s = 2,5-50<br />

f/f 1 = 2,5-35<br />

4,0 Nm 125 A • • • • • •<br />

RD 9123, RD 9125,<br />

RD 9127<br />

Manufacturer Wieland:<br />

WKM<br />

2,5/15<br />

rated voltage<br />

AC/DC 500 V<br />

2 2,5<br />

1,5<br />

MC<br />

LES<br />

2 f/f 1 = 0,5-2,5<br />

sol = 0,5-4<br />

s = 1,5-2,5<br />

0,5 Nm 24 A • • • •<br />

RD 9045, RD 9041<br />

WKM<br />

4/15<br />

rated voltage<br />

AC/DC 500 V<br />

2 4<br />

2,5<br />

1,5<br />

2 f/f 1 = 0,5-4<br />

sol = 0,5-6<br />

s = 1,5-4<br />

0,6 Nm 32 A • • •<br />

RK 9062<br />

RK 9064<br />

RK 9109<br />

RK 9104<br />

WK 4/U<br />

rated voltage<br />

AC/DC 690 V<br />

2 4<br />

2,5<br />

1,5<br />

2 f/f 1 = 0,5-4<br />

sol = 0,5-6<br />

s = 1,5-4<br />

0,6 Nm 41 A • • • • • • •<br />

81<br />

References/Types


Technical data<br />

HENPAS<br />

Service<br />

LES<br />

MC<br />

Mi<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Terminals<br />

Junction terminals for copper (Cu) and aluminium (Alu) conductors<br />

<strong>DK</strong><br />

Fixed in<br />

<strong>cable</strong> <strong>junction</strong> <strong>boxes</strong><br />

Clamping<br />

units per<br />

pole<br />

Rated connecting capacity of terminals per types of<br />

conductors<br />

sol (round) s (round) sol (sector) s (sector)<br />

Tightening<br />

torque<br />

Current<br />

carrying<br />

capacity<br />

K 7042/K 7052 2 10-50 16-95 50-95 35-95 20 Nm 160 A 95 mm 2<br />

K 1204/K 1205 2<br />

4<br />

K 2404/K 2405 2<br />

4<br />

16-50<br />

16-50<br />

25-50<br />

25-50<br />

16-150<br />

16-70<br />

25-240<br />

25-120<br />

50-150<br />

50-70<br />

50-185<br />

50-120<br />

35-150<br />

35-70<br />

35-240<br />

35-120<br />

20 Nm<br />

20 Nm<br />

40 Nm<br />

40 Nm<br />

250 A<br />

250 A<br />

400 A<br />

400 A<br />

Rated cross-section of terminals<br />

150 mm 2<br />

240 mm 2<br />

KV<br />

Rated connecting capacity K 2404/K 2405<br />

Rated connecting capacity K 1204/K 1205<br />

16-150 mm 2 16-70 mm 2 16-150 mm 2 240 mm 2 25-120 mm 2 240 mm 2<br />

16-150 mm 2 16-70 mm 2 16-70 mm 2 25-185/ 25-120 mm 2 25-120 mm 2<br />

240 mm 2<br />

25-185/ 25-185/<br />

References/Types<br />

82


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Operating and ambient conditions, characteristics of the material<br />

Application area<br />

D ..., DP ...,<br />

DE ...,<br />

K 9 ..., K 8 ...,<br />

RD ..., RK ...<br />

K 7004/5<br />

K 1204/5<br />

K 2404/5<br />

Mi FM ..<br />

Operating and ambient conditions<br />

EKA 20,<br />

ERA 20,<br />

DPS 02<br />

Suitable for indoor installation and<br />

outdoor installation, protected against weather influences<br />

AXM ... KX ... KF ...<br />

Suitable for<br />

outdoor<br />

installation.<br />

Service<br />

Ambient temperature<br />

- Average value<br />

over 24 hours<br />

- Maximum value<br />

- Minimum value<br />

Relative<br />

humidity<br />

- short-time<br />

Fire protection<br />

in the event<br />

of internal faults<br />

Material<br />

Temperature<br />

resistance<br />

Burning behaviour<br />

- Glow wire test<br />

IEC 60 695-2-1<br />

- UL Subject 94<br />

Resistant to occasional cleaning procedures (direct jet)<br />

max. with high-pressure cleaner without additives<br />

water pressure: max. 65 bar, water temperature:<br />

max. 50° C, distance ≥ 0.5 m<br />

box and <strong>cable</strong> entries at least IP 65<br />

+ 35° C<br />

+ 40° C<br />

− 25° C<br />

50% at 40° C<br />

100% at 25° C<br />

+ 35° C<br />

+ 40° C<br />

− 25° C<br />

50% at 40° C<br />

100% at 25° C<br />

+ 35° C<br />

+ 40° C<br />

− 25° C<br />

50% at 40° C<br />

100% at 25° C<br />

+ 35° C<br />

+ 40° C<br />

− 20° C<br />

50% at 40° C<br />

100% at 25° C<br />

+ 35° C<br />

+ 40° C<br />

− 20° C<br />

50% at 40° C<br />

100% at 25° C<br />

+ 55° C<br />

+ 70° C<br />

− 40° C<br />

Demands<br />

Minimum requirements<br />

placed on electrical devices from standards - Glow wire test in accordance with IEC 60 695-2-1<br />

and laws governing operational equipment - 650° C for <strong>boxes</strong> and <strong>cable</strong> glands<br />

- 850° C for conducting components<br />

Characteristics of the material<br />

PS polystyrene<br />

thermoplastic<br />

− 40° C to<br />

+ 70° C<br />

Toxic behaviour halogen-free 3)<br />

Chemical<br />

resistance 2)<br />

- Acid 10 %<br />

- Lye 10 %<br />

- Alcohol<br />

- Petrol (MAK) 1)<br />

- Benzene (MAK) 1)<br />

- Mineral oil<br />

PC polycarbonate<br />

thermoplastic,<br />

impact-resistant<br />

− 40° C to<br />

+ 90° C<br />

TPE PA Polyamide PC-GFS<br />

thermoplastic<br />

− 25° C to<br />

+ 80° C<br />

750° C<br />

V-2<br />

flame-retardant<br />

750° C<br />

V-2<br />

flame-retardant<br />

750° C<br />

−<br />

flame-retardant<br />

self-extinguishing self-extinguishing<br />

silicone-free<br />

halogen-free 3)<br />

silicone-free<br />

halogen-free 3)<br />

silicone-free<br />

(+ = resistance 0 = partially resistance − = not resistant)<br />

+<br />

+<br />

+<br />

−<br />

−<br />

0<br />

+<br />

+<br />

0<br />

+<br />

−<br />

+<br />

+<br />

+<br />

+<br />

0<br />

0<br />

0<br />

− 20° C to<br />

+ 70° C<br />

− 40° C to<br />

+ 100° C<br />

50% at 40° C<br />

100% at 25° C<br />

PC-GFS<br />

thermoplastic<br />

− 40° C to<br />

+ 100° C<br />

960° C<br />

−<br />

flame-retardant<br />

960° C<br />

−<br />

flame-retardant<br />

960° C<br />

V-0<br />

flame-retardant<br />

self-extinguishing self-extinguishing self-extinguishing<br />

halogen-free 3)<br />

silicone-free<br />

+<br />

0<br />

+<br />

+<br />

+<br />

+<br />

halogen-free 3)<br />

silicone-free<br />

on<br />

request<br />

halogen-free 3)<br />

silicone-free<br />

1) (MAC) - Maximum allowable concentration (work place)<br />

2) The specifications on chemical resistance are a general guide. In individual cases it may be necessary to check resistance in combination with other<br />

chemicals and ambient conditions (termperature, concentration, etc.)<br />

3) „Halogen-free“ in accordance with IEC 754-2 „Common test methods for <strong>cable</strong>s - Determination of the amount of halogen acid gas“.<br />

+<br />

+<br />

0<br />

+<br />

−<br />

+<br />

Technical data HENPAS<br />

LES<br />

MC<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

83<br />

References/Types


Service<br />

<strong>DK</strong><br />

Technical data<br />

HENPAS<br />

LES<br />

MC<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Standards<br />

Hensel <strong>cable</strong> <strong>junction</strong> <strong>boxes</strong> and <strong>cable</strong> entry systems comply with the following standards and requirements:<br />

KV<br />

1. Cable <strong>junction</strong> <strong>boxes</strong><br />

- IEC 60 998 -1<br />

Connecting devices for low voltage circuits<br />

for household and similar purposes<br />

Part 1: General requirements<br />

- IEC 60 998 -2 -1<br />

Connecting devices for low voltage circuits<br />

for household and similar purposes<br />

Part 2-1: Particular requirements for connecting devices<br />

as separate entities with screw-type terminals<br />

- IEC 60 998 -2 -5<br />

Connecting devices for low voltage circuits<br />

for household and similar purposes<br />

Part 2-5: Particular requirements to <strong>junction</strong> <strong>boxes</strong> for<br />

terminals or connecting device<br />

2. Cable <strong>junction</strong> <strong>boxes</strong> with terminal blocks<br />

- IEC 60 998 -2 -5<br />

Particular requirements to <strong>junction</strong> <strong>boxes</strong> for<br />

terminals or connecting device<br />

- EN 60 947 -7-1<br />

Low-voltage switchgear and controlgear,<br />

Part 7: Auxiliary equipment;<br />

Section 1 - Terminal blocks for copper conductors<br />

- IEC 60 529<br />

Degrees of protection provided by enclosures (IP-Code)<br />

3. Conduit entries (ERA 20)<br />

- EN 60 423<br />

Conduits for electrical pursposes - Outside diameters of conduits<br />

for electrical installations and threads for conduits and fittings<br />

- IEC 60 999<br />

Connecting devices<br />

Safety requirements for screw-type and screwless-type<br />

clamping units for electrical copper conductors<br />

Mi<br />

- IEC 60 529<br />

Degrees of protection provided by enclosures (IP-Code)<br />

- IEC 754-2<br />

Common test methods for <strong>cable</strong>s - Determination of the<br />

amount of halogen acid gas.<br />

References/Types<br />

84


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Cable <strong>junction</strong> <strong>boxes</strong> with functional integrity<br />

Junction box with connected <strong>cable</strong>s<br />

after testing.<br />

Safety circuits must remain operational for a<br />

sufficient period in accordance with the national<br />

regulations governing fire protection requirements<br />

for <strong>cable</strong> installations during exposure to fire.<br />

This ensures that electrotechnical equipment such<br />

as luminaires, lifts, smoke outlets, alarm systems<br />

etc. are supplied with power for 30 or 90 minutes<br />

and thereby enable people to leave the building<br />

and assist rescue teams in carrying out their work.<br />

When planning and implementing these <strong>cable</strong><br />

installations, the current specimen regulation for<br />

fire protection requirements in these installations<br />

must be observed.<br />

FK Cable <strong>junction</strong> <strong>boxes</strong> comply with these<br />

requirements when used together with typeapproved<br />

<strong>cable</strong>s as well as suitable <strong>cable</strong><br />

clamps or mounting devices.<br />

• Cable <strong>junction</strong> <strong>boxes</strong> tested for functional<br />

integrity in the event of a fire.<br />

• Degree of protection IP 65<br />

• Box made from sheet steel with powder coating,<br />

pastel orange RAL 2003<br />

• No additional fire load, no toxic or corrosive<br />

emissions<br />

• Functinal integrity according to DIN 4102 part 12<br />

(German standard) in connection with<br />

function-retaining <strong>cable</strong>s of 0.5-16 mm 2<br />

• Protection against direct contact also maintained<br />

due to the box<br />

• Captive cover with 4 screw fixings<br />

Service<br />

<strong>DK</strong><br />

KV<br />

Test temperature curve in accordance<br />

with DIN 4102<br />

Box fixing with plugs:<br />

Anchor (building materials) Fischer type ... Hilti type ...<br />

FIS V.. FNA.. FBS.. FBN.. FHY.. HUS.. HSA.. HIT-HY..<br />

Limestone blocks KS 12 x x x<br />

Building bricks Mz 12 x x x<br />

Airbricks HLz 12 x x<br />

Limestone air blocks KSL 12 x x<br />

Prestressed concrete slabs<br />

Porous concrete slabs => 3.3 x x<br />

Porous concrete blocks => 4 x x<br />

Concrete => B25 / =< B55 x x x x x<br />

Please observe the current approvals and notes from the manufacturer of the plugs.<br />

Ambient conditions in working operation:<br />

Application area<br />

Ambient temperature<br />

- Average value over 24 hours<br />

- Maximum value<br />

- Minimum value<br />

Relative humidity<br />

- short-time<br />

FK 9xx5 FK 9259<br />

x<br />

Suitable for indoor installation and outdoor installation, protected against weather influences<br />

+ 35° C<br />

+ 40° C<br />

− 25° C<br />

50 % at 40° C<br />

100 % at 25° C<br />

+ 35° C<br />

+ 40° C<br />

− 5° C<br />

50 % at 40° C<br />

100 % at 25° C<br />

Material sheet steel with powder coating, pastel orange RAL 2003<br />

halogen-free<br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

Standards and regulations:<br />

IEC 60 998 -1<br />

IEC 60 998 -2 -1<br />

IEC 60 529<br />

IEC 60 947 -7 -1<br />

EN 50 262<br />

Technical data<br />

IEC 60 998 -2 -5<br />

DIN 4102 Part 2<br />

DIN 4102 Part 12<br />

85<br />

References/Types


Service<br />

<strong>DK</strong><br />

KV<br />

Technical data<br />

HENPAS<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Cable <strong>junction</strong> <strong>boxes</strong> for hazardous areas<br />

Potentially explosive atmospheres according to ATEX<br />

From 1.1.2003 onwards within the European Union only materials that comply with EU directive 94/9/EG (ATEX 100a)<br />

must be installed in new systems.<br />

The change creates a complete separation between dust-explosion protection and gas-explosion protection.<br />

Zone definitions*:<br />

GAS-explosive area<br />

Zone 0 - gases<br />

An area in which an explosive atmosphere comprising a mixture<br />

of air and flammable substances in the form of gases, vapours or<br />

liquid aerosol is present continuously, for long periods or frequently.<br />

Zone 1 - gases<br />

An area in which it is expected that an explosive atmosphere<br />

comprising a mixture of air and flammable substances in the form<br />

of gas, vapour or liquid aerosol may occur occasionally during<br />

normal operations.<br />

DUST-explosive area<br />

Zone 20 - dust<br />

An area in which an explosive atmosphere in the form of a cloud of<br />

combustible dust in air is present continuously, for long periods or<br />

frequently.<br />

Zone 21 - dust<br />

An area in which it is expected that an explosive atmosphere in the<br />

form of a cloud of combustible dust in air is likely to occur occasionally<br />

during normal operations.<br />

Mi<br />

Zone 2 - gases<br />

An area in which it is not expected that an explosive atmosphere<br />

comprising a mixture of air and flammable substances in the form<br />

of gas, vapour or liquid aerosol occurs during normal operation;<br />

but if it does occur, then only for a short period.<br />

Zone 22 - dust<br />

An area in which it is not expected that an explosive atmosphere in<br />

the form of a cloud of combustible dust in air occurs during normal<br />

operations; but if it does occur, then only for a short period.<br />

MC<br />

Selecting the equipment*<br />

1. The proprietor specifies the separation into explosive areas (dust/gas), the zones and the type of material (atmosphere/dust) with flash<br />

point, ignition temperature, conductive or non-conductive.<br />

2. This information must be used to define the requirements in regard to selecting the right equipment.<br />

3. The device ID must provide information about where and in which areas the equipment must be used (device category and,<br />

consequently, allocation to the hazard zone).<br />

LES<br />

* Please include possible different local regulations.<br />

References/Types<br />

86


<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

Technical details<br />

Cable <strong>junction</strong> <strong>boxes</strong> for hazardous areas<br />

Device ID:<br />

Manufacturer<br />

Service<br />

Special marking<br />

according to ATEX<br />

KX 2025<br />

Type<br />

<strong>DK</strong><br />

compliance according to EU Directive 94/0/EG (ATEX 100a)<br />

EEx<br />

Explosion-proof according to European standard<br />

KV<br />

n<br />

Protection type “n”:<br />

Protection type that is used on electrical equipment, so that during normal operations and under certain<br />

unusual conditions defined in EN 50 021:1999 they are unable to ignite a surrounding explosive atmosphere.<br />

IIA<br />

Device group II:<br />

These devices are for use in all areas which may be endangered by an explosive atmosphere apart from<br />

underground mines and above-ground mining systems.<br />

Class A: non-sparking equipment<br />

Mi<br />

3 Category 3: Devices in this category are for use in areas in which it is not expected that an explosive<br />

atmosphere caused by gases, vapours, liquid aerosols or dust/air mixtures will occur but if they do occur,<br />

then generally only seldom and for a short period.<br />

G<br />

Ex-atmosphere G = Gas<br />

MC<br />

D<br />

Ex-atmosphere D = dusts<br />

T 80º C<br />

maximum surface temperature for the device:<br />

highest temperature that can occur under the most unfavourable conditions on the surface of the device.<br />

Compare with specification for ignition temperature.<br />

LES<br />

T6<br />

Temperature class T6 = 85º C<br />

IP 65 Degree of protection according to IEC 60 529<br />

690 V Rated voltage<br />

2005 Year of manufacture<br />

HENPAS<br />

Technical data<br />

87<br />

References/Types


Technical data<br />

HENPAS<br />

LES<br />

MC<br />

Mi<br />

KV<br />

<strong>DK</strong><br />

Service<br />

<strong>DK</strong> Cable <strong>junction</strong> <strong>boxes</strong><br />

References/Types<br />

88