<strong>Oil</strong> <strong>Pump</strong> <strong>Type</strong> <strong>KSN</strong><br />

<strong>Sizes</strong> <strong>25</strong> <strong>…</strong> <strong>2000</strong><br />

General Data Sheet<br />

For specific information on this product, please contact Danfoss Burner Components<br />

Identification<br />

<strong>KSN</strong> 1500 R (Example)<br />

R<br />

L<br />

Clockwise rotation<br />

Counter clockwise<br />

rotation<br />

1500 Capacity 1500 l/h<br />

<strong>KSN</strong> oil pumps are designed for industrial oil<br />

burner systems up to <strong>2000</strong> l/h. The pumps<br />

are supplied as 2-pipe versions but can be<br />

changed to 1-pipe operation. They are available<br />

in 10 sizes. The actual pressure range can<br />

be changed to four alternatives.<br />

Application and Features<br />

• Light and heavy oil<br />

• 1 and 2-pipe operation<br />

• 1-stage<br />

• Built-in pressure regulator<br />

• 5 alternative pressure ranges including<br />

feed/transfer applications<br />

• Drilling for heaing cartridge.<br />

Capacity at 4.3 cSt., 10 bar, 2800 min -1 .<br />

Note!<br />

Shaft rotation and location of connections<br />

are seen from shaft end.<br />

R-rotation<br />

L-rotation<br />

Pressure<br />

Suction<br />

Return<br />

Connections<br />

Example shows R-rotation pump.<br />

On L-rotation pumps all connections are<br />

reversed.<br />

Function<br />

From the suction inlet (S) oil is drawn through<br />

the gear set, where the pressure is increased.<br />

By means of the piston (V) and the spring in<br />

the pressure regulator the pressure is kept<br />

constant at the value set on adjustment screw<br />

(P 1 ).<br />

Changeover between<br />

1 and 2-pipe operation<br />

Surplus oil is returned through the piston to<br />

the return outlet (R).<br />

Changeover to 1-pipe operation<br />

The <strong>KSN</strong> pumps can be changed to 1-pipe<br />

operation by removing the by-pass screw (A)<br />

in the regulator piston (V) and seal the return<br />

outlet with a plug.<br />

Bleeding<br />

Bleeding must be performed through the<br />

pressure outlet (P) or the pressure gauge port<br />

(P n ).<br />

P 1<br />

S<br />

R<br />

P<br />

P n<br />

P s<br />

H<br />

Pressure adjustment<br />

Suction inlet<br />

Return outlet<br />

Pressure outlet<br />

Pressure gauge port<br />

Vacuum gauge port<br />

Drilling for heating cartridge<br />

Warranty<br />

For pumps used outside the stated technical<br />

data and used with oil containing abrasive<br />

particles Danfoss cannot give any warranty.<br />

2-pipe:<br />

Screw (A) fitted<br />

1-pipe:<br />

Screw (A) removed<br />

520F0353 DKBD.PD.014.E7.02


Technical Data<br />

<strong>KSN</strong> Size <strong>25</strong>-160 300-600 1000-<strong>2000</strong><br />

Viscosity range (measured in suction inlet) cSt. (mm 2 /s) 2.5 - 450<br />

Pressure range bar Dependent of spring type*<br />

Pressure ranges (Spring types 0/1/2/3/4) bar 0.5-1.5 / 1-4 / 2-9 / 6-<strong>25</strong> / 15-40<br />

Factory setting bar Min. pressure<br />

Max. pressure in suction inlet/return outlet bar 4<br />

Speed min -1 1400-3450 1400-1700<br />

Weight kg 2.8 3.8 8.6<br />

Ambient temperature °C –10 to +90<br />

Storage temperature °C –20 to +60<br />

Temperature of medium °C Max. 180<br />

* All pumps are supplied with spring types 2/3/4<br />

Capacity<br />

<strong>Sizes</strong> <strong>25</strong>-600<br />

Capacity<br />

<strong>Sizes</strong> 45-600<br />

2 520F0353 DKBD.PD.014.E7.02


Capacity<br />

<strong>Sizes</strong> 1000-<strong>2000</strong><br />

Operating torque<br />

<strong>Sizes</strong> <strong>25</strong>-600<br />

Power<br />

consumption<br />

Opacity torque<br />

<strong>Sizes</strong> 45-600<br />

Power<br />

consumption<br />

Operating torque<br />

<strong>Sizes</strong> 1000-<strong>2000</strong><br />

Power<br />

consumption<br />

520F0353 DKBD.PD.014.E7.02 3


Dimensions<br />

<strong>Type</strong> Size a2 a3 b1 c2 c3 c4 c5 c6 c7<br />

<strong>KSN</strong> <strong>25</strong> - 160 20 33 51 14 16 40 20 55.5 76<br />

<strong>KSN</strong> 150- 600 30 38 70 14 16 40 20 69.5 76<br />

<strong>KSN</strong> 1000-<strong>2000</strong> 38 45 96 15 18 77 29 86.5 124<br />

<strong>Type</strong> Size c8 d1 sw/e d2 d3 d4 e1 f1 f2 f3 f4<br />

<strong>KSN</strong> <strong>25</strong>- 160 131.5 12 27/31.2 54 80 5.6 R 3 /8” 165 32 116 17<br />

<strong>KSN</strong> 150- 600 145.5 12 27/31.2 54 80 7.5 R 1 /2” 165 32 116 17<br />

<strong>KSN</strong> 1000-<strong>2000</strong> 210.5 18 46/53.1 60 100 10 R 3 /4” 194 26.5 150 17.5<br />

<strong>Type</strong> Size f6 f7 g1 g2 g3 h1 h2 L1 L2<br />

<strong>KSN</strong> <strong>25</strong>- 160 32.5 92 40 27 67 11 10.5 18 9<br />

<strong>KSN</strong> 150- 600 35 92 45 27 72 11 16 22 12<br />

<strong>KSN</strong> 1000-<strong>2000</strong> 50 120 65 40 105 13 18.5 30 20<br />

All pump sizes have G 1 /4” connections on the front for the measurement of vacuum and pump pressure.<br />

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products<br />

already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.<br />

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.<br />

4 520F0353 DKBD.PD.014.E7.02 Produced by Danfoss Industri Service - Advertising 06.01 LN/Bi.ro