<strong>Gr<strong>und</strong>lagen</strong> <strong>FlexRay</strong> BasicsV 1.1 18<br />
Figure 2.10 Linear passive bus [FREPLS06]<br />
A passive star does not have a main line. The maximal bus length is lBus = lStub n + lStub m =<br />
24m. In practical applications, commonly 3 nodes with a length lStub n = 8m are used. The<br />
maximum number of nodes is 22. However, the length of the stub lStub n decreases rapidly<br />
with each additional stub, e.g. with 6 stubs, lStub n