<strong>BOGE</strong> AIR. THE AIR TO WORK.<br />

<strong>BOGE</strong> <strong>ED</strong> <strong>Series</strong>:<br />

<strong>Refrigerant</strong> <strong>Dryers</strong><br />

CONSISTENT PRESSURE DEW POINT<br />

The stainless steel 3-in-1 heat exchanger<br />

with integrated separator assures a consistent<br />

pressure dew point under differing ambient<br />

conditions. The low pressure differential ensures<br />

high quality compressed air.<br />

FULLY AUTOMATIC VALVE<br />

A check valve is designed to proportionally<br />

control the fl ow of the refrigerant into the<br />

heat exchanger according to the air volume<br />

fl ow. The R134a and R407c coolants ensure<br />

environmentally friendly operation.<br />

STATIC CONDENSER<br />

A static condenser means the <strong>ED</strong> 3 - <strong>ED</strong> 17<br />

series is air cooled working reliably without<br />

any additional fan or energy consumption.<br />

AIR COOL<strong>ED</strong> CONDENSER<br />

Extremely large cooling coils means that<br />

the condenser is able to work effectively<br />

and effi ciently even in the most adverse<br />

conditions to cool the saturated compressed<br />

air – for maximum operational safety.<br />

CONTROL<br />

A user friendly control is equipped with an<br />

on/off switch, L<strong>ED</strong> displays for dryer and<br />

compressor operation, and a L<strong>ED</strong> bar<br />

graph display for the pressure dew point.<br />

AMBIENT TEMPERATURE<br />

The design feature of the <strong>ED</strong> 3 - <strong>ED</strong> 17 series<br />

is the static condenser which allows the<br />

dryer to be air cooled irrespective of variable<br />

ambient temperatures (see conversion factors).<br />

Installation instructions<br />

For the standard dryers, the room and/or<br />

ambient temperature may not exceed +49°C<br />

(<strong>ED</strong> 3 - 17) or +43°C <strong>ED</strong> 23 - 137), and not<br />

fall below +4.4°C. The refrigerant dryer should<br />

have suffi cient free space around it in order<br />

to ensure satisfactory cooling air circulation.<br />

A suffi ciently dimensioned drain pipe is<br />

required to take away the condensate.<br />

Design conditions<br />

The max. inlet temperature is +55°C<br />

(<strong>ED</strong> 3 - <strong>ED</strong> 17) or +58°C respectively<br />

(<strong>ED</strong> 23 - <strong>ED</strong> 137).<br />

Features:<br />

• Dew point bar graph display (<strong>ED</strong> 3 - <strong>ED</strong> 40)<br />

and/or L<strong>ED</strong> display (<strong>ED</strong> 53 - <strong>ED</strong> 137)<br />

• Timer controlled condensate drain<br />

(except <strong>ED</strong> 3: type Float)<br />

• Coolant R134a (<strong>ED</strong> 3 - <strong>ED</strong> 27)<br />

and R407c (<strong>ED</strong> 40 - <strong>ED</strong> 137)<br />

Options:<br />

• Standard bypass line<br />

2<br />

4<br />

1<br />

5<br />

1) Heat exchanger with integrated separator<br />

2) Compact design low corrosion galvanized<br />

steel housing<br />

3) Air cooled condenser (<strong>ED</strong> 23 - <strong>ED</strong> 137 only)<br />

4) Control valve for proportional refrigerant<br />

fl ow into heat exchanger<br />

5) Compressor<br />

3


<strong>Refrigerant</strong> compressed air dryers <strong>ED</strong> 3 – <strong>ED</strong> 137<br />

Flow rate: 0.33 – 13.67 m³/min<br />

Max. operating pressure: 16 bar<br />

<strong>BOGE</strong><br />

Model<br />

* Emitted sound pressure level of 45 dB(A) upwards.<br />

** <strong>ED</strong> 3 – <strong>ED</strong> 17 equipped with bi-frequency control.<br />

Flow rate* Max.<br />

operating<br />

pressure<br />

Pressure<br />

differential<br />

at full load<br />

Electrical<br />

power<br />

consumption<br />

Electrical<br />

connection<br />

V/Hz**<br />

Compressed<br />

air<br />

connection<br />

Cooling<br />

air<br />

demand<br />

Dimensions<br />

W x D x H<br />

m 3 /min m 3 /h bar bar kW 50 Hz m 3 /h mm kg<br />

<strong>ED</strong> 3 0.33 20 16 0.36 0.24 230 R 3 / 8 Raumluft 320x 320x382 19<br />

<strong>ED</strong> 5 0.50 30 16 0.49 0.24 230 R 3 / 8 Raumluft 320x 320x382 19<br />

<strong>ED</strong> 10 1.00 60 16 0.27 0.34 230 R 3 / 4 Raumluft 368x 394x568 28<br />

<strong>ED</strong> 13 1.33 80 16 0.46 0.42 230 R 3 / 4 Raumluft 368x 394x568 30<br />

<strong>ED</strong> 17 1.67 100 16 0.34 0.58 230 R 3 / 4 Raumluft 500x 500x568 41<br />

<strong>ED</strong> 23 2.33 140 16 0.24 0.58 230 R 1 1020 363x 861x601 50<br />

<strong>ED</strong> 27 2.67 160 16 0.25 0.60 230 R 1 1020 363x 861x601 53<br />

<strong>ED</strong> 40 4.00 240 16 0.30 0.87 230 R 1 1020 363x 921x601 58<br />

<strong>ED</strong> 53 5.25 315 16 0.15 1.10 230 R 2 1980 443x 971x761 72<br />

<strong>ED</strong> 60 6.00 360 16 0.17 1.30 230 R 2 1980 443x 971x761 78<br />

<strong>ED</strong> 78 7.83 470 16 0.21 1.48 230 R 2 2640 443x 971x761 85<br />

<strong>ED</strong> 97 9.67 580 16 0.16 1.90 230 R 2 2640 493x1151x811 100<br />

<strong>ED</strong> 113 11.33 680 16 0.20 2.45 230 R 2 4500 493x1151x811 112<br />

<strong>ED</strong> 137 13.67 820 16 0.25 2.55 230 R 2 4500 493x1251x811 134<br />

Conversion factors<br />

<strong>Refrigerant</strong> dryers are designed according to DIN ISO 7183 for 7 bar operating pressure, +25°C ambient temperature, and +35°C inlet temperature.<br />

In case of different operating pressures and temperatures the following conversion factors apply.<br />

Conversion factors <strong>ED</strong> 23 – <strong>ED</strong> 137<br />

Ambient/cooling air temperature °C 25 30 35 40 43<br />

Factor f 1 1.00 0.92 0.85 0.78 0.74<br />

Inlet temperature °C 35 40 45 50 55 58<br />

Factor f 2 1.00 0.84 0.71 0.63 0.54 0.50<br />

Operating overpressure bar 3 4 5 6 7 8 9 10 11 12 13 14<br />

Factor f 3 0.79 0.87 0.92 0.96 1.00 1.03 1.07 1.10 1.13 1.16 1.18 1.21<br />

Sample (for pressure dew point +3°C) and <strong>Series</strong> <strong>ED</strong> 3 – <strong>ED</strong> 17<br />

Volume fl ow m3 /h 55 Factor<br />

Ambient temperature (f ) 1 °C 35 = 1.00<br />

Inlet temperature (f ) 2 °C 45 = 0.69<br />

Operating pressure (f ) 3 bar 10 = 1.07<br />

<strong>BOGE</strong> KOMPRESSOREN<br />

Otto <strong>Boge</strong> GmbH & Co. KG<br />

P.O. Box 10 07 13 · 33507 Bielefeld<br />

Otto-<strong>Boge</strong>-Straße 1–7 · 33739 Bielefeld<br />

Fon +49 5206 601-0<br />

Fax +49 5206 601-200<br />

info@boge.de · www.boge.de<br />

Conversion factors <strong>ED</strong> 3 – <strong>ED</strong> 17<br />

Ambient/cooling air temperature °C 25 30 35 40 45 49<br />

Factor f 1 1.00 1.00 1.00 1.00 1.00 1.00 (always 1.00 due to static condenser)<br />

Inlet temperature °C 35 40 45 50 55<br />

Factor f 2 1.00 0.82 0.69 0.59 0.50<br />

Operating overpressure bar 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

Factor f 3 0.70 0.80 0.87 0.92 0.96 1.00 1.03 1.05 1.07 1.08 1.10 1.11 1.12 1.13<br />

V 55<br />

= = = 74 <strong>ED</strong> 13<br />

f 1 x f 2 x f 3 1.00 x 0.69 x 1.07<br />

Weight<br />

313-GB-2-09.2009/T · Technical changes and errors reserved.