170710 Analog ultrasound sensor<br />

2/2<br />

The sensor is protected against reverse polarity.<br />

The sensor output supplies an impressed current and is loaded during short-circuit operation.<br />

Ideally, the output should be loaded with a resistance of R L =0Ω.<br />

Technical data<br />

Permissible operating voltage<br />

Current consumption (without load)<br />

Load resistance<br />

Current output<br />

Measuring range<br />

Minimum distance between sensor and a<br />

laterally reflecting wall<br />

Resolution<br />

24 V DC<br />

< 35 mA<br />

< 400 Ohm<br />

4 to 20 mA<br />

500 to 150 mm<br />

>75mm<br />

± 1mm<br />

Operating/ambient temperature range –20 to +75 °C<br />

Temperature drift<br />

Linearity error<br />

Measuring pulse frequency<br />

0.1%/°C<br />

0.2% FSD* (*FSD = full scale deflection)<br />

40 Hz<br />

Sound cone aperture angle Approx. 5°<br />

Reverse polarity protection<br />

Yes<br />

Degree of protection IP 65<br />

Materials (housing)<br />

Weight<br />

Subject to change<br />

Plastic<br />

0.250 kg<br />

240<br />

mm<br />

200<br />

180<br />

160<br />

140<br />

Level<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Characteristic curve<br />

0<br />

8 9 10 11 12 13<br />

Sensor output<br />

14 15 16 mA 17<br />

The oszillations at the beginning and the end of the characteristic curve are caused by<br />

the type of sensor construction.<br />

For the characteristic curve displayed, the distance between the sensor and the bottom<br />

of the container was adjusted to 330 mm.<br />