10<br />

<strong>DUCTABLE</strong> <strong>FAN</strong>-<strong>COILS</strong><br />

High pressure<br />

BSW<br />

The fan-coil units for conduits are designed for installation on false ceilings thanks to their low height.<br />

Equipped with a fan, coil, heat exchanger and filter, these units are an ideal solution for air-conditioning in guest houses,<br />

shops, hotels, hospitals, offices, etc. Another important feature of these units is the savings and ease of servicing<br />

them, compared with other air-conditioning systems.<br />

E<br />

10<br />

155


E 10<br />

<strong>DUCTABLE</strong> <strong>FAN</strong>-<strong>COILS</strong><br />

High pressure<br />

BSW<br />

TECHNICAL SPECIFICATIONS<br />

CODE<br />

504016<br />

504017<br />

504018<br />

504019<br />

504020<br />

504021<br />

504022<br />

MODEL<br />

BSW 10<br />

BSW 20<br />

BSW 30<br />

BSW 40<br />

BSW 50<br />

BSW 60<br />

BSW 70<br />

Ref. capacity<br />

Water 7/12ºC<br />

kW<br />

4,0<br />

7,0<br />

9,2<br />

10,6<br />

13,1<br />

27,8<br />

50,6<br />

Heat.capacity<br />

Water 50ºC<br />

kW<br />

5,0<br />

8,5<br />

11,2<br />

12,8<br />

16,8<br />

32,5<br />

60,1<br />

Voltage<br />

(50 Hz~)<br />

V<br />

230-1<br />

230-1<br />

230-1<br />

230-1<br />

230-1<br />

230-1<br />

230-1<br />

Water<br />

connections<br />

Ø (‘’)<br />

1/2<br />

1/2<br />

3/4<br />

3/4<br />

1<br />

1 1/4<br />

1 1/4<br />

Air<br />

flow<br />

m 3 /h<br />

837<br />

1423<br />

1951<br />

2131<br />

3002<br />

4678<br />

9250<br />

Sound level<br />

dB (A)<br />

68<br />

69<br />

70<br />

69<br />

74<br />

78<br />

81<br />

Dimensions<br />

(width x depth x height)<br />

mm<br />

650 x 533 x 299<br />

1000 x 533 x 299<br />

1100 x 533 x 324<br />

1339 x 533 x 324<br />

1339 x 533 x 374<br />

1341 x 853 x 674<br />

2028 x 853 x 674<br />

- Data refers to 2-pipe coils For 4-pipe fan-coils, see the technical catalogue.<br />

- Add CD for right connection.<br />

- Add CI for left connection.<br />

Example: BSW 50-CD<br />

THERMOSTATS AND CONTROLS<br />

E<br />

10<br />

Thermostat<br />

RC-2/X6 Thermostat<br />

RC-1 Thermostat<br />

4 units control interface<br />

PM (programmable microprocessor) Thermostat<br />

Optional PM<br />

Optional PM RC-2/X6<br />

Optional PM<br />

Infrared IC control*<br />

Description<br />

Electronic thermostat with stop/winter/summer/ and temperature display<br />

Remote control with stop/winter/summer and 3 speeds<br />

4 unit control interface with only one thermostat<br />

Standard<br />

Air temperature NTC probe<br />

Air temperature NTC probe<br />

Water temperature NTC probe<br />

Infrared control<br />

For models<br />

All models<br />

All models<br />

All models<br />

All models<br />

All models<br />

All models<br />

All models<br />

All models<br />

* Not included in units with electric resistance.<br />

OPTIONAL ACCESSORIES<br />

Valves 2-pipe, 4-pipe installation:<br />

MODEL VALVE<br />

2-pipe – 3-way systems<br />

2-pipe –3-point 3-way float valve system<br />

2-pipe – modulating 0-10 V 3-way system<br />

4-pipe – 3-way systems<br />

4-pipe –3-point 3-way float valve system<br />

4-pipe – modulating 0-10 V 3-way system<br />

2-pipe – 2-way system<br />

2-pipe –3-point 2-way float valve system<br />

2-pipe – modulating 0-10 V 2-way system<br />

4-pipe – 2-way system<br />

4-pipe –3-point 2-way float valve system<br />

4-pipe – modulating 0-10 V 2-way system<br />

Cut-off valve/flow adjustment 2-pipe system<br />

Cut-off valve/flow adjustment 4-pipe system<br />

2 cut-off valves 2-pipe system<br />

2 cut-off valves 4-pipe system<br />

Interconnecting pipe for 2-pipe system<br />

Interconnecting pipe for 4-pipe system<br />

BSW 10 Ø (“)<br />

1/2<br />

1/2<br />

1/2<br />

1/2 - 1/2<br />

1/2 - 1/2<br />

1/2 - 1/2<br />

1/2<br />

1/2<br />

1/2<br />

1/2 - 1/2<br />

1/2 - 1/2<br />

1/2 - 1/2<br />

1/2<br />

1/2 - 1/2<br />

1/2<br />

1/2 - 1/2<br />

-<br />

-<br />

BSW 20 Ø (“)<br />

3/4<br />

3/4<br />

3/4<br />

3/4 - 1/2<br />

3/4 - 1/2<br />

3/4 - 1/2<br />

3/4<br />

3/4<br />

3/4<br />

3/4 - 1/2<br />

3/4 - 1/2<br />

3/4 - 1/2<br />

3/4<br />

3/4 - 1/2<br />

3/4<br />

3/4 - 1/2<br />

-<br />

-<br />

BSW 30 a 50 Ø (“)<br />

1<br />

1<br />

1<br />

1 - 3/4<br />

1 - 3/4<br />

1 - 3/4<br />

1<br />

1<br />

1<br />

1 - 3/4<br />

1 - 3/4<br />

1 - 3/4<br />

1<br />

1 - 3/4<br />

1<br />

1 - 3/4<br />

-<br />

-<br />

BSW 60 Ø (“)<br />

1 1/2<br />

1 1/2<br />

1 1/2<br />

1 1/2 - 1 1/2<br />

1 1/2 - 1 1/2<br />

1 1/2 - 1 1/2<br />

1 1/2<br />

1 1/2<br />

1 1/2<br />

1 1/2 - 1 1/2<br />

1 1/2 - 1 1/2<br />

1 1/2 - 1 1/2<br />

1 1/2<br />

1 1/2 - 1 1/2<br />

1 1/2<br />

1 1/2 - 1 1/2<br />

-<br />

-<br />

BSW 70 Ø (“)<br />

2<br />

2<br />

2<br />

2 - 1 1/2<br />

2 - 1 1/2<br />

2 - 1 1/2<br />

2<br />

2<br />

2<br />

2 - 1 1/2<br />

2 - 1 1/2<br />

2 - 1 1/2<br />

2<br />

2 - 1 1/2<br />

2<br />

2 - 1 1/2<br />

-<br />

-<br />

A - Valve + actuator<br />

B - Interconnection pipe<br />

C - Cut-off/adjustment valve<br />

156<br />

HITECSA Commitment