DUCTABLE FAN-COILS - Hitecsa
DUCTABLE FAN-COILS - Hitecsa
DUCTABLE FAN-COILS - Hitecsa
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
E<br />
10<br />
<strong>DUCTABLE</strong> <strong>FAN</strong>-<strong>COILS</strong><br />
High pressure<br />
BSW<br />
The fan-coil units for conduits are designed for installation on false ceilings thanks to their low height.<br />
Equipped with a fan, coil, heat exchanger and filter, these units are an ideal solution for air-conditioning in guest houses,<br />
shops, hotels, hospitals, offices, etc. Another important feature of these units is the savings and ease of servicing<br />
them, compared with other air-conditioning systems.<br />
E<br />
10<br />
155
E 10<br />
<strong>DUCTABLE</strong> <strong>FAN</strong>-<strong>COILS</strong><br />
High pressure<br />
BSW<br />
TECHNICAL SPECIFICATIONS<br />
CODE<br />
504016<br />
504017<br />
504018<br />
504019<br />
504020<br />
504021<br />
504022<br />
MODEL<br />
BSW 10<br />
BSW 20<br />
BSW 30<br />
BSW 40<br />
BSW 50<br />
BSW 60<br />
BSW 70<br />
Ref. capacity<br />
Water 7/12ºC<br />
kW<br />
4,0<br />
7,0<br />
9,2<br />
10,6<br />
13,1<br />
27,8<br />
50,6<br />
Heat.capacity<br />
Water 50ºC<br />
kW<br />
5,0<br />
8,5<br />
11,2<br />
12,8<br />
16,8<br />
32,5<br />
60,1<br />
Voltage<br />
(50 Hz~)<br />
V<br />
230-1<br />
230-1<br />
230-1<br />
230-1<br />
230-1<br />
230-1<br />
230-1<br />
Water<br />
connections<br />
Ø (‘’)<br />
1/2<br />
1/2<br />
3/4<br />
3/4<br />
1<br />
1 1/4<br />
1 1/4<br />
Air<br />
flow<br />
m 3 /h<br />
837<br />
1423<br />
1951<br />
2131<br />
3002<br />
4678<br />
9250<br />
Sound level<br />
dB (A)<br />
68<br />
69<br />
70<br />
69<br />
74<br />
78<br />
81<br />
Dimensions<br />
(width x depth x height)<br />
mm<br />
650 x 533 x 299<br />
1000 x 533 x 299<br />
1100 x 533 x 324<br />
1339 x 533 x 324<br />
1339 x 533 x 374<br />
1341 x 853 x 674<br />
2028 x 853 x 674<br />
- Data refers to 2-pipe coils For 4-pipe fan-coils, see the technical catalogue.<br />
- Add CD for right connection.<br />
- Add CI for left connection.<br />
Example: BSW 50-CD<br />
THERMOSTATS AND CONTROLS<br />
E<br />
10<br />
Thermostat<br />
RC-2/X6 Thermostat<br />
RC-1 Thermostat<br />
4 units control interface<br />
PM (programmable microprocessor) Thermostat<br />
Optional PM<br />
Optional PM RC-2/X6<br />
Optional PM<br />
Infrared IC control*<br />
Description<br />
Electronic thermostat with stop/winter/summer/ and temperature display<br />
Remote control with stop/winter/summer and 3 speeds<br />
4 unit control interface with only one thermostat<br />
Standard<br />
Air temperature NTC probe<br />
Air temperature NTC probe<br />
Water temperature NTC probe<br />
Infrared control<br />
For models<br />
All models<br />
All models<br />
All models<br />
All models<br />
All models<br />
All models<br />
All models<br />
All models<br />
* Not included in units with electric resistance.<br />
OPTIONAL ACCESSORIES<br />
Valves 2-pipe, 4-pipe installation:<br />
MODEL VALVE<br />
2-pipe – 3-way systems<br />
2-pipe –3-point 3-way float valve system<br />
2-pipe – modulating 0-10 V 3-way system<br />
4-pipe – 3-way systems<br />
4-pipe –3-point 3-way float valve system<br />
4-pipe – modulating 0-10 V 3-way system<br />
2-pipe – 2-way system<br />
2-pipe –3-point 2-way float valve system<br />
2-pipe – modulating 0-10 V 2-way system<br />
4-pipe – 2-way system<br />
4-pipe –3-point 2-way float valve system<br />
4-pipe – modulating 0-10 V 2-way system<br />
Cut-off valve/flow adjustment 2-pipe system<br />
Cut-off valve/flow adjustment 4-pipe system<br />
2 cut-off valves 2-pipe system<br />
2 cut-off valves 4-pipe system<br />
Interconnecting pipe for 2-pipe system<br />
Interconnecting pipe for 4-pipe system<br />
BSW 10 Ø (“)<br />
1/2<br />
1/2<br />
1/2<br />
1/2 - 1/2<br />
1/2 - 1/2<br />
1/2 - 1/2<br />
1/2<br />
1/2<br />
1/2<br />
1/2 - 1/2<br />
1/2 - 1/2<br />
1/2 - 1/2<br />
1/2<br />
1/2 - 1/2<br />
1/2<br />
1/2 - 1/2<br />
-<br />
-<br />
BSW 20 Ø (“)<br />
3/4<br />
3/4<br />
3/4<br />
3/4 - 1/2<br />
3/4 - 1/2<br />
3/4 - 1/2<br />
3/4<br />
3/4<br />
3/4<br />
3/4 - 1/2<br />
3/4 - 1/2<br />
3/4 - 1/2<br />
3/4<br />
3/4 - 1/2<br />
3/4<br />
3/4 - 1/2<br />
-<br />
-<br />
BSW 30 a 50 Ø (“)<br />
1<br />
1<br />
1<br />
1 - 3/4<br />
1 - 3/4<br />
1 - 3/4<br />
1<br />
1<br />
1<br />
1 - 3/4<br />
1 - 3/4<br />
1 - 3/4<br />
1<br />
1 - 3/4<br />
1<br />
1 - 3/4<br />
-<br />
-<br />
BSW 60 Ø (“)<br />
1 1/2<br />
1 1/2<br />
1 1/2<br />
1 1/2 - 1 1/2<br />
1 1/2 - 1 1/2<br />
1 1/2 - 1 1/2<br />
1 1/2<br />
1 1/2<br />
1 1/2<br />
1 1/2 - 1 1/2<br />
1 1/2 - 1 1/2<br />
1 1/2 - 1 1/2<br />
1 1/2<br />
1 1/2 - 1 1/2<br />
1 1/2<br />
1 1/2 - 1 1/2<br />
-<br />
-<br />
BSW 70 Ø (“)<br />
2<br />
2<br />
2<br />
2 - 1 1/2<br />
2 - 1 1/2<br />
2 - 1 1/2<br />
2<br />
2<br />
2<br />
2 - 1 1/2<br />
2 - 1 1/2<br />
2 - 1 1/2<br />
2<br />
2 - 1 1/2<br />
2<br />
2 - 1 1/2<br />
-<br />
-<br />
A - Valve + actuator<br />
B - Interconnection pipe<br />
C - Cut-off/adjustment valve<br />
156<br />
HITECSA Commitment