European Technical Approval Technical Approval ETA 12 ... - Hempel
European Technical Approval Technical Approval ETA 12 ... - Hempel
European Technical Approval Technical Approval ETA 12 ... - Hempel
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Page 8 of 46 of <strong>ETA</strong> <strong>12</strong>/0581, issued on 17.01.2013<br />
3.3.2 Example of CE marking<br />
Example of CE marking and accompanying information for product:<br />
“CE” symbol<br />
xxxx<br />
<strong>Hempel</strong> A/S<br />
Lundtoftevej 150<br />
DK-2800 Kgs Lyngby<br />
Denmark<br />
Number of the notified body<br />
Name and address of the<br />
manufacturer<br />
YY<br />
xxxx-CPD-xxxx<br />
<strong>ETA</strong> <strong>12</strong>/0581<br />
<strong>ETA</strong>G 018, Part 1 and 2<br />
Fire Protective products<br />
HEMPACORE ONE 43600 /<br />
HEMPACORE ONE FD 43601<br />
Last two digits of year of<br />
affixing CE marking<br />
Number of the EC<br />
Certificate of Conformity<br />
Number of the <strong>ETA</strong><br />
Reference to the<br />
corresponding <strong>ETA</strong>G<br />
Product name<br />
See <strong>ETA</strong> for relevant<br />
characteristics<br />
4 Assumptions under which the fitness of the product(s) for the intended<br />
use was favourably assessed<br />
The detailed description and conditions of the manufacturing process of product, and all the<br />
relevant design and installation criteria of product are specified in the technical documentation<br />
of the manufacturer deposited with the ITeC. The main aspects of this information are specified<br />
in the following chapters.<br />
4.1 Manufacturing<br />
The <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> is issued for the reactive coatings HEMPACORE ONE 43600<br />
and HEMPACORE ONE FD 43601 on the basis of agreed data/information deposited with the<br />
ITeC, which identifies the products that have been assessed and judged. Changes to the<br />
products or production processes, which could result in this deposited data/information being<br />
incorrect, should be notified to ITeC before the changes are introduced. ITeC will decide<br />
whether such changes affect the <strong>ETA</strong> and consequently the validity of the CE marking on the<br />
basis of the <strong>ETA</strong> and, if so, whether further assessment or alterations to the <strong>ETA</strong> shall be<br />
necessary.<br />
4.2 Installation<br />
4.2.1 Reactive coating<br />
4.2.2 Primer<br />
This <strong>ETA</strong> is issued under the assumption that the application of HEMPACORE ONE 43600 and<br />
HEMPACORE ONE FD 43601 occurs in accordance with the manufacturer’s instructions.<br />
The manufacturer shall provide an installation guide for his product in accordance with the<br />
installation provisions followed for the assessement in this <strong>ETA</strong>.<br />
A primer from the list of approved primers in section 1.2.2, or other compatible primers of the<br />
same family as specified by the manufacturer, shall be used. The preparation of the steel