Integrated breath<strong>in</strong>g<br />

Forget about time-consum<strong>in</strong>g, multiple-tube connections between the anesthesia<br />

mach<strong>in</strong>e, breath<strong>in</strong>g system, and patient. Our <strong>in</strong>tegrated breath<strong>in</strong>g system (IBS) <strong>in</strong>tegrates<br />

an ascend<strong>in</strong>g bag-<strong>in</strong>-bottle, patient circuit, and CO 2<br />

absorber <strong>in</strong> one compact unit.<br />

That means no tub<strong>in</strong>g between the breath<strong>in</strong>g<br />

system and mach<strong>in</strong>e and only two tubes—<br />

for <strong>in</strong>spiration and expiration—between the<br />

breath<strong>in</strong>g system and patient. The manual bag<br />

connection is located under the APL valve.<br />

Sett<strong>in</strong>g up for a procedure is fast, and clean<strong>in</strong>g<br />

is easy. In less than sixty seconds the breath<strong>in</strong>g<br />

system can be taken apart for clean<strong>in</strong>g, without<br />

any need of special tools. The foolproof design<br />

prevents reassembly errors after clean<strong>in</strong>g.<br />

Bag-<strong>in</strong>-bottle<br />

The ascend<strong>in</strong>g bellows is designed to prevent air from<br />

be<strong>in</strong>g drawn <strong>in</strong>to the breath<strong>in</strong>g system <strong>in</strong> the event<br />

of a leakage. The capacity is up to 1500 ml, mak<strong>in</strong>g<br />

it suitable for adults, pediatrics, and neonates.<br />

Valves<br />

Yellow valve flaps allow visual supervision of <strong>in</strong>spiration<br />

and expiration. An APL valve is also <strong>in</strong>tegrated and<br />

valid <strong>in</strong> the manual and spontaneous modes.<br />

i-SORB absorber<br />

Available <strong>in</strong> reusable or disposable versions, i-SORB<br />

m<strong>in</strong>imizes the waste of unused soda lime thanks to its<br />

flow-optimized design. Soda lime capacity is 900 g.<br />

The absorber can be replaced while<br />

the mach<strong>in</strong>e is <strong>in</strong> operation.<br />