07.01.2014 Views

LIFE09200604007 Tabish - Homi Bhabha National Institute

LIFE09200604007 Tabish - Homi Bhabha National Institute

LIFE09200604007 Tabish - Homi Bhabha National Institute

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Synopsis<br />

3.2.1 S phase arrest at 6 h time point: Mean percent S phase arrest in MPN patient<br />

cell lines was 18.54% (range 8.84% - 31.06%) at 5 µM; and 19.14% (range 10.49% -<br />

35.52%) at 8 µM and in control cell lines it was 13.85% (range 4.77% - 22.09%) at 5<br />

µM; and 13.58% (range 7.5% - 16.2%) at 8 µM.<br />

3.2.2 S phase arrest at 24 h time point: Mean percent S phase arrest in MPN patient<br />

cell lines was 19.53% (range 3.26% - 31.33%) at 5 µM; and 20.09% (range 3.73% -<br />

30.72%) at 8 µM and in control cell lines it was 17.68% (range 8.10% - 27.24%) at 5<br />

µM; and 16.67% (range 6.28% - 28.09%) at 8 µM.<br />

3.2.3 G2/M phase arrest at 6 h time point: Mean percent G2/M arrest in MPN patient<br />

cell lines was 4.86% (range 0 - 9.25%) at 5 µM; and 4.87% (range 0 - 9.48%) at 8 µM<br />

and in control cell lines it was 9.57% (range 5.30% - 16.82%) at 5 µM; and 9.55%<br />

(range 4.03% - 17.05% ) at 8 µM.<br />

3.2.4 G2/M phase arrest at 24 h time point: Mean percent G2/M arrest in MPN<br />

patient cell lines was 3.65% (range 0 - 9.9%) at 5 µM; and 3.39% (range 0 - 8.8%) at<br />

8 µM and control cell lines it was 5.19% (range 0.01% - 17.01%) at 5 µM; and 4.83%<br />

(range 0.01% - 15.9%) at 8 µM.<br />

4. Apoptotic response in MPN and control samples in vitro: This experiment was done<br />

on 20 MPN and 10 control cell lines.<br />

4.1 Percent cell death after γ-radiation exposure: Percent cell death after radiation<br />

exposure was higher in control cell lines (19.22%, range 9.05% - 42.82% at 5 Gy; and<br />

22.09%, range 12.04% - 42.4% at 10 Gy) as compared to MPN patient cell lines<br />

(9.84%, range 8.3% - 12.7% at 5 Gy; and 10.84%, range 8.3% - 12.7% at 10 Gy). The<br />

mean difference between the two groups was 9.38% at 5 Gy and 11.25% at 10 Gy<br />

which was statistically significant (p=0.0003 at 5 Gy; p=0.0002 at 10 Gy).<br />

4.2 Percent cell death after BPDE exposure: Similarly percent cell death after BPDE<br />

exposure was higher in control cell lines (23.25%, range 10.49% - 41.79% at 5 µM;<br />

and 24.98%, range 10.23% - 51.76% at 8 µM) as compared to MPN patient cell lines<br />

(13.57%, range 8.02% - 21.77% at 5 µM and 14.02%, range 8.46% - 24.69% at 8 µM).<br />

The mean difference between the two groups was 9.68% at 5 µM and 10.98% at 8 µM<br />

which was statistically significant (p=0.0009 at 5 µM and 8 µM BPDE concentration).<br />

13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!